• Title/Summary/Keyword: Winding technique

검색결과 157건 처리시간 0.04초

세가지 형태의 영구자석 배열에 따른 직선형 동기 전동기의 특성해석 (Characteristic Analysis of Iron-cored PM Linear Motor in Three Types Synchronous Motor in Three Types)

  • 장석명;유대준;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.116-118
    • /
    • 2003
  • The Slotless Permanet-magnet linear synchronous motors (PMLSM) have been developed for factory automation, transportation applications, wafer steppers, conveyance system, and so on[1]. The current analysis and design are treated in air-cored PMLSM. The main purpose of this paper is to provide a general design and analysis framework for the iron-cored linear permanent-magnet machines. Based on field solution using two dimensional analytical technique the magnetic field required magnet volume size, optimal winding thickness size, winding flux linkage and thrust will be discussed.

  • PDF

Estimation of the Separate Primary and Secondary Leakage Inductances of a Y-Δ Transformer Using Least Squares Method

  • Kang, Yong-Cheol;Lee, Byung-Eun;Hwang, Tae-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.538-544
    • /
    • 2010
  • This paper proposes an estimation algorithm for the separate primary and secondary leakage inductances of a three phase $Y-\Delta$ transformer using least squares method. The voltage equations from the primary and secondary windings are combined into a differential equation to estimate the separate primary and secondary leakage inductances in order to use the line current of the delta winding. Separate primary and secondary leakage inductances are obtained by applying least squares method to the differential equation. The performance of the proposed algorithm is validated under transient states, such as magnetic inrush and overexcitation, as well as in the steady state with various cut-off frequencies of low-pass filter. The proposed technique can accurately generate separate leakage inductances both in the steady and transient states.

발전기 운전중 회전자 진단에 관한 연구 (On-Line Diagnosis Method for Generator Rotor Windings)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2002
  • A shorted-turn test was performed at the Sininchon combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line diagnosis system. The flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

발전기 운전중 회전자 계자권선의 단락 진단기법에 관한 연구 (Shorted-Turn Detction Techniques for Generator Rotor)

  • 이영준;김희동;빅종정;주영호;조지원;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1721-1724
    • /
    • 1998
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas. turbine generator #4. The test was conducted using a permanent flux probe and digital oscilloscope. The flux probe installed in the generator air gap, senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a waveform analysis technique that can identify the pole location, slot number, and number of shorted-Turns with each slot.

  • PDF

MPB BLDC 전동기의 제어기 개발 (Development of Controller for MPB BLDC Motor)

  • 김상욱;김보열
    • 전기학회논문지P
    • /
    • 제50권3호
    • /
    • pp.117-124
    • /
    • 2001
  • The aim of this paper is to develop a controller of multi-phase bipolar brushless DC (MPB BLDC) motors for an electric bicycle. A MPB BLDC motor has a Permanent magnet rotor in which the magnetic arrangement is radial to the shaft and integral to the rotor laminations. This technique concentrates flux, giving a higher flux density than a surface-mounted PM motor and increases reluctance torque. The stator of MPB BLBC motor has parallel winding, allowing multi-phase separate independent controllability. It gets much more high power than wye-connection at same low voltage. The conventional techniques of exited with modulation(EWM), bidirection control, and partial square wale control are Proposed with one H-bridge and two photo sensors per phase. The Proposed controller is satisfied for the limited speed control and designed for system stability Experimental results show the performance of the proposed controller of MPB BLDC motors for an electric bicycle.

  • PDF

고온 초전도 선재의 굽힘횟수와 온도차에 의한 임계전류저하특성 (Critical Current Degradation Characteristics by Temperature Difference of L$N_2$-Normal in Repetitive Bending Strain of High Temperature Superconducting Tape)

  • 김해준;김석환;송규정;김해종;배준한;조전욱;성기철
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2003
  • Critical current(Ic) degradation of HTS tapes after bending is one of the hottest issues in HTS development and application studies. Many people are measuring Ic degradations for effect of bending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the Ic degradation after repetitive bending. at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC) and superconductiing tapes that strain is imposed measured critical current by temperature difference of L$N_2$ and normal temperature. Like this, critical current could measure that degradation about 1~3% by temperature difference. These results will amount the most important basis data in power electric machine of superconductivity cable, magnet, etc that winding work is require.

  • PDF

Extended Wing Technique Approach for the Detection of Winding Interturn Faults in Three-phase Transformers

  • Balla, Makarand Sudhakar;Suryawanshi, Hiralal Murlidhar;Choudhari, Bhupesh Nemichand
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.288-297
    • /
    • 2015
  • This paper presents a novel approach to diagnose interturn insulation faults in three-phase transformers that operate at different loading conditions. This approach is based on the loci of instantaneous symmetrical components and requires the measurement of three input primary winding currents and voltages to diagnose faults in the transformer. The effect of unbalance supply conditions, load variations, constructional imbalance, and measurement errors when this methodology is used is also investigated. Wing size or length determines the loading on the transformer. Wing travel and area determine the degree of severity of fault. Experimental results are presented for a 400/200 V, 7.5 kVA transformer to validate this method.

함침기법에 따른 인버터 구동 유도전동기 고정자 권선의 절연성능 평가 (Evaluation of Insulation Performance for Stator Winding of the Inverter Driven Induction Motor According to Impregnation Methods)

  • 황돈하;강동식;이인우;김동희;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.487-492
    • /
    • 2006
  • Inverter driven induction motors with high speed switching and advanced PWM techniques are widely used for variable speed applications. Recently, the insulation failures of stator winding have attracted much concern due to high dv/dt of IGBT PWM inverter output. In this paper, the detailed insulation test results of 26 low-voltage induction motors are presented. Six different types of insulation techniques are applied to 26 motors. The insulation characteristics are analyzed with partial discharge, inception voltage, AC current, and dissipation factor tests. Also, breakdown tests by high voltage pulses are performed. From the above test data the effects due to different wires and insulation techniques on the insulation characteristics of low-voltage induction motors are compared and analyzed. The insulation technique to enhance the insulation strength is suggested from the test results.

  • PDF

발전기 회전자 권선의 건전성 평가 (Assessment of Insulation Condition for Generator Rotor Windings)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

임피던스 성분을 이용한 매입형 영구자석 전동기의 고정자 절연파괴 고장의 초기 검출 기법 (Early Detection Technique in IPM-type Motor with Stator-Turn Fault using Impedance Parameter)

  • 정채림;김경태;허진
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.612-619
    • /
    • 2013
  • This paper proposes an early diagnosis technique for the stator-turn fault (STF) in an interior permanent magnet (IPM)-type brushless DC (BLDC) motor using the impedance parameter. We have analyzed the varying characteristics owing to the STF through various experiments and the finite element method (FEM). As a result, we have presented a simple method for fault detection. This technique can be applied without requiring a fast Fourier transform (FFT) and the calculation of the negative-sequence impedance. The fault detection system works on the basis of the comparison the measured impedance with the database impedance. The variations in the characteristics owing to the STF as well as the proposed technique have been verified through the simulation and experiment.