• Title/Summary/Keyword: Winding technique

Search Result 157, Processing Time 0.023 seconds

A Study on Design method and Fabrication Technique of Power Dividers in Generalized Type (일반회된 형식의 전력분배기의 설계법 및 제작기술에 관한 연구)

  • 김동일;이성표;정세모;김태균
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1993.10a
    • /
    • pp.25-32
    • /
    • 1993
  • The design theory of a generalized n-way power divider with arbitrary dividing rations for CATV and/or MATV systems which consists of ideal multi-winding transformers and resistors only was presented. Since the circuit elements have not frequency dependence the proposed power divider is to be of exetremely broad band-width. Furthermore as a result of computer simulation the frequency characteristics are very good in spite of errors of turn numbers and hence it was confirmed that the proposed design theory is valid.

  • PDF

Development of the On-line Partial Discharge Measuring Sensor and System on Stator Windings for Hydro Generator (수력발전기 고정자권선용 운전중 부분방전 측정 센서 및 시스템 개발)

  • Kang, D.S.;Sun, J.H;Hwang, D.H.;Yun, Y.H.;Seo, I.S.;Shin, B.C.;Klm, H.I.;Lee, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.103-106
    • /
    • 2005
  • A lot of R&D on the diagnosis of stator winding insolation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. The purpose of this paper is to describe the method of the on-line partial discharge measurement on stator windings for hydro- generator with ceramic sensor and measuring system. We developed ceramic coupling sensor, partial discharge measuring system, terminal box and index parameters.

  • PDF

The Prediction of Conducted EMI In PWM Inverter Fed Induction Motor Drive System (PWM인버터-유도전동기 구동시스템의 전도노이즈 예측)

  • 안정준;이정호;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.579-588
    • /
    • 1999
  • This paper presents a technique for predicting the conductLu EMI(Electro Magnetic Interference) produced b by PWM inverter-induction motor drive system. To obtain the simulation models for prediction of conduct떠 n noise, high frequency model of an inverter leg with parasitic elements and multi-coil model of stator winding M are designed. Finally, the results are confirmLu from simulation and experiments.

  • PDF

The Optimal Frequency Domain Choice to Measure Partial Discharge in Rotator Machine (회전기 부분방전신호 측정을 위한 최적 주파수 영역 선정)

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2052-2053
    • /
    • 2007
  • Recently, the importance of supplying the reliable electric power is increasing. Breaking insulation of stator winding is major cause of fault in rotator machine. On-line PD detecting is useful technique to diagnose rotator machine. However, interpretation of its results in time domain is very complex because of the mixed results with PD(Partial Discharge) and noise signal. Therefore, the results were analyzed in frequency domain by FFT (Fast Fourier Transform) to detect precise PD signals. The purpose of this paper is to describe the optimal frequency range to discriminate the PD and noise signal.

  • PDF

Failure Behavior of Pin-jointed Cylindrical Composites Using Acoustic Emission Technique (AE기법을 이용한 원통형 복합재의 핀 체결부 파괴거동)

  • Yoon, Sung-Ho;Hwang, Young-Eun;Kim, Chan-Gyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.9-15
    • /
    • 2012
  • In this paper, the bearing strengths and fracture behaviors of the pin-jointed carbon fiber/epoxy composites were investigated through pin loading test with acoustic emission technique. The composites were fabricated by a filament winding process, and three types of laminated patterns were considered. Type 1 was fabricated with stitch, Type 2 was fabricated without stitich and Type 3 was fabricated with prepregs. According to the results, bearing strength of Type 1 was 3.3% lower than that of Type 2 and that of Type 3 was highest. Type 1 and Type 2 revealed a net-tension failure mode, respectively, whereas Type 3 pattern exhibited a bearing failure mode. Also, acoustic emission energy of the Type 3 was higher than that of the Type 1 and Type 2. Therefore, the Type 3 was found to be structurally safer than the Type 1 and Type 2.

Internal Strain Monitoring of Filament Wound Pressure Tanks using Embedded Fiber Bragg Grating Sensors (삽입된 광섬유 브래그 격자 센서를 이용한 필라멘트 와인딩된 복합재료 압력탱크의 내부 변형률 모니터링)

  • Kim, C.U.;Park, S.W.;Park, S.O.;Kim, C.G.;Kang, D.H.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.17-20
    • /
    • 2005
  • In-situ structural health monitoring of filament wound pressure tanks were conducted during water-pressurizing test using embedded fiber Bragg grating (FBG) sensors. We need to monitor inner strains during working in order to verify the health condition of pressure tanks more accurately because finite element analyses on filament wound pressure tanks usually show large differences between inner and outer strains. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. We fabricated a standard testing and evaluation bottle (STEB) with embedded FBG sensors and performed a water-pressurizing test. In order to increase the survivability of embedded FBG sensors, we suggested a revised fabrication process for embedding FBG sensors into a filament wound pressure tank, which includes a new protecting technique of sensor heads, the grating parts. From the experimental results, it was demonstrated that FBG sensors can be successfully adapted to filament wound pressure tanks for their structural health monitoring by embedding.

  • PDF

Filtering Techniques to Reduce the Transient Voltage of High Voltage Induction Motor on H-bridge cascaded 7- level Inverte (H-Bridge 7-레벨 인버터 구동시 고압 유도전동기에서 발생하는 과도전압 저감을 위한 필터기술)

  • Kwon, Young-Mok;Kim, Jae-Chul;Kim, Young-Sung;Lee, Yang-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.47-50
    • /
    • 2005
  • In this paper, we investigate a filtering technique to reduce the adverse effect of long motor leads on H-bridge cascaded 7-level inverter fed ac motor drive. The switching surge voltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. However, the effect of switching surge appears un seriousin high voltage induction motor than low voltage induction motor. Consequently, we demonstrated that the filter connected to the motor terminals greatly reduces the transient voltage stress and ringing, moreover we show lowers the dv/dt of the inverter switching pulse. The results of simulation show the suppression of dv/dt and the reduced peak voltage at the motor end of a long cable.

  • PDF

Velocity and temperature profiles of Al/water micro fluid in a circular tube with swirl

  • Chang, Tae-Hyun;Lee, Kwon Soo;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.677-684
    • /
    • 2013
  • A lot study of convection heat transfer on internal flow has been extensively conducted in the past decades using of high specific surface area, increasing heat transfer coefficient, swirling flow and improving the transport properties. This study concerned with the application of a tangential slot swirl generator for improving heat transfer in a horizontal circular copper tube. The Al particles(about $100{\sim}130{\mu}m$) was employed for this experimental work. 3D PIV(particle image velocimetry) technique has employed to measure velocity profiles of Al particles with and without swirl flow. The copper tube is heated uniformly by winding of a heating coil for heat transfer work, having a resistance of 9 ohm per meter. Experiments are performed in the Reynolds number range of 6,800~12,100 with swirl and without swirl using Al particles. Experimental data for comparison of Nusselt number is presented that of with swirl and without swirl along the test tube for the Reynolds numbers. The Nusselt number is improved with increasing of Reynolds numbers or swirl intensities along the test tube. The Nusselt number with swirl flow is about 60.0% to 119.0% higher than that obtained by the Dittus-Boelter equation.

Design and Operation Characteristics of Novel 2-Phase 6/5 Switched Reluctance Motor

  • Hieu, Pham Trung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2194-2200
    • /
    • 2014
  • This paper presents a design of novel 2-phase 6/5 switched reluctance motor (SRM) for an air-blower application. This type of motor is suitable for the applications that require high speed and only one directional rotation as air-blower. The desired air-blower is unidirectional application, and requires a wide positive torque region without torque dead-zone. In order to get a wide positive torque region without torque dead-zone during phase commutation, asymmetric inductance characteristic with non-uniform air-gap is considered. The proposed motor can be operated at any rotor position. The proposed 6/5 SRM uses short flux path technique that achieved by means of winding configuration and lamination geometry. The purpose of short flux path is to reduce the core loss and the absorption MMF in the stator. The proposed 2-phase 6/5 SRM is verified by finite element method (FEM) analysis and Matlab-Simulink. In order to verify the design, a prototype of the proposed motor was manufactured for practical system.

The Aging Characrteristic Analysis of Mica-Epoxy Insulation Materials (마이카-에폭시 절연재료의 열화특성분석)

  • Yoo, Yeong-Sik;Kim, Hee-Gon;Song, Woo-Chang;Lee, Jae-Hyung;Park, Yong-Kwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.82-89
    • /
    • 1998
  • The experimental results using the X -ray technique, the position and structure of mica crystal are not observed the phase change of aging and sound specimen respectively. However, We could observe the intensity difference of crystal element in both atmospheres. The analysis of mica-epoxy materials by optical microscope are shown that the each surface of sound and aging specimens are different in both atmospheres Also, the experimental results have shown that the potassium ions of mica cristal are substituted by hydrogen ions at boundary area of mica-epoxy and/or mica-mica. On components made of mica, a potassium ion of big atomic radius, is replaced by hydrogen ion of small atomic radius. The voids are created by the difference of radius progressed by combined stresses. Through these phenomena, it has been proposed that the conductive layers made of potassium enable the voids to form and the cracks to create by high electric field.