50 kVA 주상용 몰드변압기의 설계 및 특성평가 (The Design and Performance Test of Mold Transformer for Outdoor Pole)

  • 조한구;이운용;황보국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

대전류 출력형 Flat Transformer 설계 및 해석 기술 (Design and Simulation Technologies of Flat Transformer with High Power Current)

  • 한세원;조한구;우병철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

OLTC를 고려한 33 MVA 초전도 변압기 설계 (Design of a 33 MVA HTS Transformer with OLTC)

  • 최지훈;이승욱;박명진;김우석;최경달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.885-886
    • /
    • 2006
  • We have proposed a 100 MVA, 3 phases, 154 kV class HTS transformer which will substitute for 60 MVA conventional transformer. In this paper, we designed conceptually the structure of the superconducting windings of a single phase 33 MVA transformer. The power transformer of 154 kV class has a tertiary winding besides primary and secondary windings. So the HTS transformer should have the 3rd superconducting winding, it makes the cost of the HTS transformer high and the efficiency low. Further more we considered On Load Tap Changer (OLTC) in HTS power transformer. OLTC equipment is required for fitting to a power transformer by which the voltage ratio between the windings can be varied while the transformer is on load. We analyzed the electrical characteristics of the HTS transformer such as magnetic stress and AC loss.

  • PDF

발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘 (Advanced Algorithm for IED of Stator Winding Protection of Generator System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.

Flat Transformer 코아의 설계와 컨버터 동작 특성 (Study on designing of Flat Transformer and operating characteristics of Converter)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.587-590
    • /
    • 2003
  • The first attention in designing a transformer for low temperature rise should be to reduce losses. Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

DAB 컨버터용 전력 변압기의 누설 인덕턴스를 포함한 내부 전력 손실 분석에 관한 연구 (A Study on the Analysis of Internal Power Loss Including Leakage Inductance of Power Transformer for DAB Converter)

  • 유정상;안태영;길용만
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.95-100
    • /
    • 2022
  • In this paper, a power loss analysis technique of a high-frequency transformer of a bidirectional DAB (Dual Active Bridge) converter is reported. To miniaturize the transformer of the dual active bridge converter, a resonant inductor was designed with an air gap included low-coupled rate state core to combine leakage inductor with the resonant inductor which is required for soft-switching. In this paper, leakage inductance and magnetizing inductance, core material, type of winding and winding method are included in the dual active bridge transformer loss analysis process to enable optimal design at the initial design stage. Transformer loss analysis for dual active bridge with a switching frequency of 200 kHz and maximum output of 5 kW was executed, and elements necessary for design based on the number of turns on the primary side were graphed while maintaining the transformer turns ratio and window area. In particular, it was possible to determine the optimal number of turns and thickness of the transformer, and ultimately, the total loss of the transformer could be estimated.

시뮬레이션을 통한 자기결합을 이용한 초전도 한류기의 전류제한 특성 분석 (An Analysis on Current Limiting characteristics of an SFCL using Magnetic Coupling between Two Coils through Computer Simulation)

  • 김진석;안재민;임성훈;문종필;김재철;김철환;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.42-47
    • /
    • 2008
  • In this paper, the fault current limiting characteristics for the superconducting fault current limiter(SFCL) using magnetic coupling between two coils were investigated. The SFCL consists of a high-$T_c$ superconducting(HTSC) element and two coils. This SFCL has different characteristics that depend on the connection form, the winding direction and the inductance ratio of two coils. The impedance and the operational current of the SFCL can be adjusted higher or lower than the resistance and the critical current of HTSC element. Therefore, the SFCL can change the amplitude of the limited fault current. To confirm it, the HTSC element was modeled and the fault current limiting characteristics of the SFCL were analysed through computer simulation. It was obtained from the analysis that the connection form and the winding direction of two coils of the SFCL were the important design parameters.

붐방제기의 곡선행로 조향반경에 따른 붐의 구간별 유량제어 (Sectional Flow-rate Control of Boom Sprayer According to the Steering Radius along Winding Rows)

  • 김은수;김영주;이중용
    • Journal of Biosystems Engineering
    • /
    • 제31권3호
    • /
    • pp.146-152
    • /
    • 2006
  • Most upland in Korea have irregular field shapes. Boom sprayers working alone winding row will show considerable differences of spraying amount per unit area between left and right booms. If flow rates of both booms are equal. This phenomenon becomes significant as steering radius of sprayer decreases. This study was performed to seek a method which reduce the difference of the spray amount between left, right and center booms while spraying along curvy rows. A flow rate control method for keeping application rate of each boom section constant was proposed and experimentally proved using a boom sprayer attached to a cultivating tractor. The flow rate control device was composed of 3 ball valves and a rotary angle sensor. The rotary angle sensor showed a symmetric voltage output with respect to steering radius. The spray overlapping was happened in a boom nearby the steering center when steering radius of the sprayer was less than 5.2 m. Flow rates for left, right and center booms were regulated using ball valves based on the steering radius and spraying areas ration of right/left boom. The Maximum spraying area ratio ($S_{LR}$) of left to right boom section was 1:3.6 at the steering radius of 5.2 m. However, The Maximum achieved right and left spraying flow ratio was 1:2.7.

Half-Bridge ZCS resonant inverter 및 Cockroft-Walton회로를 사용한 공기 청정기에 관한 연구 (ESP by using Half-bridge ZCS resonant inverter and Cockroft-Walton circuit)

  • 박종웅;정종진;정현주;정종한;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1951-1953
    • /
    • 2004
  • In this study, we propose a small high voltage power supply which use a half-bridge ZCS resonant and Cockroft-Walton on circuit, for ESP (Electrostatic Precipitator). This power supply transfers energy from ZCS resonant inverter to step-up transformer and the transformer secondary is applied to the Cockroft-Walton circuit for generating high voltage as discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50 % in this ESP.

  • PDF

개선된 굽힘 시험장치를 이용한 스프링백 비의 측정 (Measurement of Springback Ratio Using a Bend Rig)

  • 김용우;공성일;남진영
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.410-415
    • /
    • 2002
  • A winding bend rig is designed to overcome the drawbacks of the conventional bend rig for measuring springback ratio of a strip or plate. Using the present bend rig, springback ratios are measured and they are compared with ones that obtained by using simple beam theory and tensile test. Theoretically, there should be no difference between the two values as far as the simple beam theory holds true for the bending test. But, within the scope of our tests, there is a difference of 5% between the two values since the specimen under bend test is subjected to a transverse shear force and friction force on the surface of the specimen.

  • PDF