• 제목/요약/키워드: Winding loss

검색결과 192건 처리시간 0.027초

A Zero Voltage Switching Phase Shift Full Bridge Converter with Separated Primary Winding

  • Kim, Young-Do;Kim, Chong-Eun;Cho, Kyu-Min;Park, Ki-Bum;Cho, In-Ho;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.379-381
    • /
    • 2008
  • Generally additional leakage inductance and two clamp diodes are adopted into the conventional phase shift full bridge (PSFB) converter for reducing the voltage stress of secondary rectifier diodes and extending the range of zero voltage switching (ZVS) operation. However, since additional leakage inductance carries the ac current similar to the primary one, the core and copper loss oriented from additional leakage inductance can be high enough to decrease the whole efficiency of DC/DC converter. Therefore, in this paper, a new ZVS phase shift full bridge converter with separated primary winding (SPW) is proposed. Proposed converter makes the transformer and additional leakage inductor with one ferrite core. Using this method, leakage inductance is controlled by the winding ratio of separated primary winding. Moreover, by manufacturing the both magnetic components with one core, size and core loss can be reduced and it turns out the improvement of efficiency and power density of DC/DC converter. The operational principle of proposed converter is analyzed and verified by the 1.2kW prototype.

  • PDF

AC Loss Effects on the Design of HTS Windings for 1 MVA Power Transformer

  • Kim, Jong-Tae;Kim, Woo-Seok;Kim, Sung-Hoon;Choi, Kyeong-Dal;Hong, Gye-Won;Joo, Hyeong-Gil;Hahn, Song-Yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.32-36
    • /
    • 2004
  • AC loss is one of the important parameters in HTS (High Temperature Superconducting) AC devices. Among the HTS AC power devices, the transformer is an essential part in electrical power system. But, AC loss is one of the most serious problems of the HTS transformer, especially with pancake windings, because high alternating magnetic field is applied perpendicularly to the surface of BSCCO wire in HTS windings of that, comparing with the other HTS AC power devices. For the reason above the calculation of AC loss generated in the HTS windings should be carried out in advance when designing the HTS transformer. In the paper we performed study for optimization of winding design to minimize the magnetization loss of HTS winding such as the spaces between pancake windings and operating temperature of HTS wire. The calculation of the AC loss was accomplished by 2-demensional Finite Element Method.

DAB 컨버터용 전력 변압기의 누설 인덕턴스를 포함한 내부 전력 손실 분석에 관한 연구 (A Study on the Analysis of Internal Power Loss Including Leakage Inductance of Power Transformer for DAB Converter)

  • 유정상;안태영;길용만
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.95-100
    • /
    • 2022
  • In this paper, a power loss analysis technique of a high-frequency transformer of a bidirectional DAB (Dual Active Bridge) converter is reported. To miniaturize the transformer of the dual active bridge converter, a resonant inductor was designed with an air gap included low-coupled rate state core to combine leakage inductor with the resonant inductor which is required for soft-switching. In this paper, leakage inductance and magnetizing inductance, core material, type of winding and winding method are included in the dual active bridge transformer loss analysis process to enable optimal design at the initial design stage. Transformer loss analysis for dual active bridge with a switching frequency of 200 kHz and maximum output of 5 kW was executed, and elements necessary for design based on the number of turns on the primary side were graphed while maintaining the transformer turns ratio and window area. In particular, it was possible to determine the optimal number of turns and thickness of the transformer, and ultimately, the total loss of the transformer could be estimated.

등가회로법에 의한 커패시터 구동 단상 유도전동기의 특성해석 (Characteristic Analysis of Capacitor Run Single-Phase Induction Motor by Equivalent Circuit Method)

  • 좌종근;김호민;김도진
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.220-226
    • /
    • 2011
  • This paper proposes a straightforward method of analyzing the operation characteristics for the capacitor run single-phase induction motor from the traditional equivalent circuit based on the revolving field theory. The proposed method consists of five procedures as follows: mechanical loss segregation, iron loss segregation and calculation of the equivalent circuit parameters, recalculation of parameters of the main winding side, calculation of the auxiliary winding magnetizing reactance and effective turn ratio, and analyzing the operation characteristics for this motor. When the characteristics are analyzed, the segregated mechanical and iron losses are considered as a loss resistance across input terminals of the equivalent circuit for the analysis. The validity of the proposed method is verified from the comparison between the computed results and the experimental ones for the operation characteristics.

단상 유도전동기의 고정자 동손 최소화를 위한 설계 방법 (Design Methodology for Minimal Stator Copper Loss in A Single-phase Induction Motor)

  • 백수황;김병택;권병일
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1536-1545
    • /
    • 2008
  • In this paper, we research a new method for efficiency improvement of a single-phase Induction motor by minimization of the stator loss. To make this, we perform winding design which is based on balanced and quasi-balanced operation condition. It gives efficiency improvement greatly but poor starting torque simultaneously. To obtain the best efficiency improvement maintaining the maximum and starting torque, the optimal winding specification and rotor dimension is determined with variation of secondary resistance, running capacitor and turn ratio. Finally, this paper gives the comparison between the simulation results and experimental results.

고온초전도 적층선재의 손실과 적층선재로 제작한 팬케이크 권선의 손실 (AC Losses of the Multi-stacked HTS tapes and Pancake Coil)

  • 이승욱;김용섭;이희준;차귀수;이지광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.776-778
    • /
    • 2004
  • In this paper, we present effect of the stacked HTS tapes. AC losses of HTS pancake windings with stacked tapes are shown. Magnetic flux density in the HTS winding under operating conditions was calculated by FEM. AC loss of the pancake winding were measured and compared with the calculated loss by using AC losses of the stacked samples. Test results show that measured results generally agreed well with the calculated value by using AC loss of 4-stacked sample data.

  • PDF

Flat TR용 핵심 쿄아의 제조와 동작 특성 안정화 연구 (Study on manufacturing and operating characteristics of Magnetic cores for Flat TR)

  • 한세원;조한구;유동욱;류명효;최광보;김성배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.23-26
    • /
    • 2003
  • The flat transformer, typically, has a number of parallel single turn secondary windings. Each secondary winding is coupled to the same primary winding. Therefore, the current in each secondary winding is equal to the ampere-turns in the primary winding, and to each other. These characteristics are particularly advantageous where parallel rectifiers are used. The windings share the current equally, with no need for ballast resistors or other added components. In this study, the ferrite magnetic core samples of Mn-Zn system for the Flat transformer are manufactured and the electrical and magnetic characteristics of its tested. The density of sample FO2-2 sintered at $1350^{\circ}C$ is $4.00kg/m^3$, which shows the good microstructural state. The initial permeability and saturation flux density of FO2 at room temperature is 2700 and 510mT, individually. The power loss of FO2 samples at 250kHz have been ranged $350kW/m^3$ to $80kW/m^3$ with temperature. And the minimum power loss of sample FO2-2 showed at $70^{\circ}C$, which property seems very positive to apply for a flat transformer.

  • PDF

Zig-Zag 귄선에 의한 내철형 주상변압기 개발에 관한 연구 (A study on the Development of the Shell-type Pole Transformer Using the Zig-Zag Winding)

  • 민윤홍;신대철
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.121-128
    • /
    • 2007
  • 본 논문에서는 세계최초로 내철형 주상변압기 코일의 권선을 일반적인 권선방법에서 Zig-Zag(가칭) 권선방법으로 설계 제작하는 방법을 제안하였으며, 또한 바니시 함침공정을 생략하고 단락강도 및 절연내력을 향상시킬 수 있는 내철형 변압기용 권선의 신프레임 구조개발 내용을 제안하였다. 기존의 주상변압기 권선방법에 비하여 전기절연 측면에서 층간 절연지의 사용매수 및 두께를 획기적으로 절감할 수 있는 장점이 있다. 또한 원가절감과 손실저감 및 단락기계력 대처능력이 우수함을 검증하였으며 국내전력회사 배전계통 주상변압기에 유용하게 활용할 수 있다.

고온초전도 더블 팬케이크 권선에서 발생하는 교류손실 측정 (AC Losses of the HTS Double Pancake Winding)

  • 이승욱;이희준;임형우;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.246-249
    • /
    • 2003
  • AC loss which is generated in an HTS wire varies with the direction of the magnetic field. This paper calculated and measured the AC loss in the HTS double pancake windings. Brandt equation is used to calculate the loss by perpendicular magnetic field. Calorimetric method is used to measure the AC loss. Results of calculated AC loss are compared with measured AC loss.

  • PDF

차단기의 차단합성성대기적에 관한 연구 (A Study on the Adapting for Interrupting Capacity Augmentation of Circuit Breaker)

  • 황석영;조무제
    • 대한전기학회논문지
    • /
    • 제33권8호
    • /
    • pp.299-309
    • /
    • 1984
  • This paper proposes the adapter for interrupting capacity augmentation of circuit breaker which can be applied in case of shortage in a existing circuit breaker's interrupting capacity due to utility system extension. The adapter utilizes two winding type of reactor instead of single winding type of reactor and the control of 2ry circuit is excuted by a triac interlocked with the system protective relays actuation so as to cut out the reactor by short circuit of the 2ry winding in normal situation and to cut in the reactor by open circuit of the 2ry winding in abnomal situation such as short circuit accident. As a result of the theoritical analysis and experiment, it is proved that the adaptor can reduce the voltage crop and iron loss due to the reactor signigicantly in normal system condition and do a role of reactor upon the power system accident.