• 제목/요약/키워드: Winding Algorithm

검색결과 126건 처리시간 0.026초

웨이블렛 변환을 이용한 변압기 보호계전 알고리즘 개발 (The Development of Protective Relaying Algorithm for Transformer Based on Wavelet Transform)

  • 홍동석;정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.485-487
    • /
    • 2001
  • Current differential protective relaying with harmonic restraint module is, in general, used to protect transformer. But It is hard to distinguish inrush and internal winding fault with differential current protective relaying. This paper presents the new protective algorithm for transformers using 3-phase differential current's d1 coefficient values in wavelet transform. Various states of transformer was simulated using EMTP. Internal winding fault and inrush are classified within shorter time using the proposed algorithm.

  • PDF

웨이블렛 변환을 이용한 변압기 보호계전 알고리즘 (Protective Relaying Algorithm for Transformer Using Wavelet Transform)

  • 홍동석;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.134-141
    • /
    • 2003
  • The power transformer is one of the very important electric facilities in power systems. Recently, current differential relay is widely used to protect such power transformer But if inrush occurs in transformer, relay can be tripped by judging like internal fault. Therefore the correct discrimination between internal winding fault, inrush and overexcitation should be performed. This paper presents a new protective relaying algorithm which discriminates inrush, internal faults and overexcitation of transformer modelled using BCTRAN and HYSDAT of EMTP. Discrimination between internal winding fault and inrush is revealed in simulation within 1/2 cycle after fault. Accordingly, it is evaluated that the proposed algorithm has better discrimination characteristics in various cases thin the current relaying for protection of transformer.

변환행렬법을 이용한 케이블 권선형 배전용 변압기 귄선의 진동모드 해석 (A Vibration Mode Analysis of Cable-type Winding for Distribution Power Transformer by using Transfer Matrix Method)

  • 신판석;정현구;윤구영
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.85-91
    • /
    • 2009
  • 본 논문에서는 배전계통에 사용되는 케이블 권선형 변압기에 전력계통에서 발생되는 서지나 고장전류에 의해서 변압기의 고압측 코일에 유도되는 전자력의 크기를 유한요소 전자계해석 프로그램(FLUX2D)을 이용하여 해석하고, 기계진동방정식을 이용하여 케이블형 권선의 고유진동주파수를 분석하였다. 변압기모델로서 1(MVA), 22,900/220([V]) 단상 외철형 Cable형을 선정하여, 권선의 각방향의 전자력을 분석하고, 고유진동 mode를 Transfer Matrix Method를 이용하여 계산하고 상용 프로그램(ANSYS)을 이용하여 분석한 결과와 비교하였다. 진동모드의 분석한 결과 제시한 수치해석 방법은 공학적인 오차범위 안에서 충분히 수용할 정도의 정확도를 보여주었다. 변압기 권선의 전자력과 진동모드 분석결과는 변압기의 절연설계 및 단락기계력에 의한 절연 구조 설계를 위한 유용한 자료로 활용될 수 있다.

코깅력이 저감된 3상 9극 10슬롯 구조의 영구자석 선형 전동기 (A Low Cogging Force Permanent Magnet Linear Motor Having 3 Phase 9 Pole 10 Slot Structure)

  • 연승환;이종진;고창섭
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권11호
    • /
    • pp.547-554
    • /
    • 2006
  • The detent force of a permanent magnet linear motor(PMLM) consists of the end force and cogging force, and should be reduced for high precision purpose applications. The cogging force comes from the electromagnetic interaction between the permanent magnets and interior teeth(or the slots) of the stator, and of which the magnitude depends on the ratio of the numbers of the armature and permanent magnet poles as well as the geometrical shape of the permanent magnet and armature pole. In order to reduce the cogging force of a PMLM, this paper proposes a new configuration which has 9 permanent magnet poles and 10 armature winding slots. By theoretical investigation of the principle of cogging force generation and simulating using finite element method, the proposed PMLM configuration is proven to give much less cogging force than the conventional configuration which has 8 permanent magnet poles and 12 armature winding slots. A proper winding algorithm, modified (A, A, A) winding method, for the proposed configuration is also suggested when the proposed PMLM is operating as a 3 phase synchronous machine. A theoretical and numerical calculation shows that the proposed configuration makes slightly bigger back-emf and thrust force under same exciting current and total number of winding turns condition.

마이크로 유전자 알고리즘을 이용한 외부 수압을 받는 필라멘트 와인딩 복합재 원통의 최적 설계 (Optimal Design of Filament Wound Composite Cylinders under External Hydrostatic Pressure using a Micro-Genetic Algorithm)

  • 문철진;권진회;최진호
    • Composites Research
    • /
    • 제23권4호
    • /
    • pp.14-20
    • /
    • 2010
  • 본 연구에서는 마이크로 유전자 알고리즘을 이용하여 외부 수압을 받는 필라멘트 와인딩 복합재 원통의 최적설계를 수행하였다. 목적함수는 파손하중과 좌굴하중을 동시에 고려하여 설계하중을 최대화하는 것이다. 좌굴 및 파손해석은 MSC.NASTRAN을 이용하였고, Carroll의 공개된 마이크로 유전자 알고리즘에 기초한 최적화작업을 수행하였다. 설계변수로는 헬리컬(helical) 와인딩 각도와 후프(hoop) 와인딩 층의 두께비가 고려되었다. 본 연구를 통해 마이크로 유전자 알고리즘을 이용하여 다양한 형상을 갖는 필라멘트 와인딩 복합재 원통의 좌굴 및 파손하중 최적화가 가능함을 확인하였고, 제안된 알고리즘이 일반 유전자 알고리즘과 비교해서도 높은 효율을 보였다.

TFT LCD 용 Power Inductor Full Automation Winding/Welding System 개발

  • 이우영;진경복;김경수
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2004년도 춘계학술대회 발표 논문집
    • /
    • pp.154-158
    • /
    • 2004
  • Power inductor is usually used in the field of the power circuit of a cellular phone, TFT LCD module etc.. This paper presents the development process of Power Inductor Full Automation Winding/Welding System for TFT LCD. This process, the process algorithm, high precision welding current control, design of welding head, high speed, high precision feeding mechanism, and user interface process control program technologies are included.

  • PDF

웨이브렛 변환기반 뉴로-퍼지를 이용한 변압기 보호계전 알고리즘 (Transformer Protective Relaying Algorithm Using Neuro-Fuzzy based on Wavelet Transform)

  • 이명윤;이종범;홍동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.607-609
    • /
    • 2004
  • A breakdown occurred in power transformer causes interruption of power transmission. Protective relay should be installed in transformer to detect such a fault. Protective relaying algorithm for transformer must be included a function to discriminate between winding fault and inrushing state. Recently, current differential relay is widely used to protect power transformer. However if inrush occurs in transformer, relay can be tripped by judging as internal fault. New algorithms are required in order to such problem. This study proposes a new protective relaying algorithm using Neuro-Fuzzy inference and wavelet. A variety of transformer transient states are simulated by BCTRAN and HYSDT in EMTP. D1 coefficients of differential current are obtained by wavelet transform. D1 coefficients and RMS of 3-phase primary voltage are used to make a target data and are trained by Nwo-Fuzzy algorithm which distinguishes correctly whether internal fault occurs or not within 1/2 after fault detection. It is evaluated that the results obtained by simulations can effectively protect a transformer by contact discriminating between winding fault and inrushing state.

  • PDF

쇄교자속비를 이용한 변압기 보호 알고리즘 (A Transformer protective Relaying Algorithm Based on Increment of Flux Linkages)

  • 강용철;이병은;김은숙;원성호;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.53-55
    • /
    • 2003
  • This paper propose a transformer protective relaying algorithm based on the increment of flux linkages (RIFL) of the Primary and secondary windings. The RIFL is equal to the turn ratio for all operating conditions except an internal faults. For a single-phase transformer and three-phase Y-Y transformer, the increments of flux linkages are calculated and their ratios are compared with the turn ratio. For a three-phase Y-$\triangle$ transformer, the difference of the increments of flux linkages are calculated to use the line currents instead of the delta winding currents, which are practically unavailable. Their ratios are compared with the turn ratio. The results of various tests show that the algorithm successfully discriminates internal faults from normal operation conditions such as magnetic inrush and overexcitation. The algorithm can not only detect internal winding faults, but reduce the relay's operating time.

  • PDF

변압기 병렬운전시 순환전류 추정 (Estimation of the Circulating Currents in the Parallel Operation of Transformers)

  • 강용철;이미선;이병은;최재선;장성일;김용균;류영식
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2147-2152
    • /
    • 2008
  • This paper proposes an algorithm to estimate the circulating currents in the transformers in parallel in an ultra high voltage system. For the Y-Y-${\Delta}$ transformers operated in parallel, there exist two kinds of the circulating currents i.e. one is between the tanks and the other between the banks of the delta side. As the former is 90 deg out of phase of the load current, it is estimated by decomposing the line current into the component 90 deg out of phase of the load current in the frequency domain. The latter is estimated in the time domain from applying the Kirchhoff's voltage law on the delta winding which gives a first-order differential equation in terms of the delta winding currents. To estimate the circulating currents between the tanks, the performance of the proposed algorithm is investigated when the impedances of the two transformer tanks are different or the taps of the on-load tap changer of the transformers are mismatched temporarily. To estimate the circulating currents between the banks, the performance of the proposed algorithm is also examined under magnetic inrush and over-excitation. Test results indicate that the algorithm can estimate the two kinds of the circulating currents successfully.

손실 저감을 위한 인버터 구동 유도 전동기의 고정자 슬롯 형상 최적화 (Optimal Stator Slot Design of Inverter-Fed Induction Motor for Reduction of Core and Winding Losses)

  • 김재우;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.86-88
    • /
    • 2004
  • In this paper, optimal stator slot shape of 3-phase inverter-fed induction motor is designed to reduce stator core and winding losses. For the analysis, the F.E.M on 1 phase band periodic condition in stator is coupled with harmonic equivalent circuit. For the optimal design, the conjugate gradient method is used as an optimizing algorithm. The stator core and winding losses are reduced by the design method. The results are verified by those of the time-step finite element analysis.

  • PDF