• Title/Summary/Keyword: Wind-ventilation condition

Search Result 39, Processing Time 0.025 seconds

Numerical Simulation Experiment on the Wind Ventilation Lane of the Local Circulation Winds in Daegu (대구지역의 국지적 대기순환풍의 환기경로에 관한 수치모의 실험)

  • Gu, Hyeon Suk;Kim, Hae Dong;Gang, Seong Dae
    • Journal of Environmental Science International
    • /
    • v.13 no.4
    • /
    • pp.367-376
    • /
    • 2004
  • In urban area, thermal pollution associated with heat island phenomena is generally regarded to make urban life uncomfortable. To overcome this urban thermal pollution problem, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane, is widely practiced in many countries. In this study, the prevailing wind ventilation lane of a local winds in Daegu during the warm climate season was investigated by using surface wind data and RAMS(Reasonal Atmospheric Model System) simulation. The domain of interest is the vicinity of Daegu metropolitan city(about 900 $km^{2})$ and its horizontal scale is about 30km. The simulations were conducted under the synoptic condition of late spring with the weak gradient wind and mostly clear sky. From the numerical simulations, the following two major conclusions were obtained: (1)The major wind passages of the local circulation wind generated by radiative cooling over the mountains(Mt. Palgong and Mt. Ap) are found. The winds blow down along the valley axis over the eastern part of the Daegu area as a gravity flow during nighttime. (2)After that time, the winds blow toward the western part of Daegu through the city center. As the result, the higher temperature region appears over the western part of Daegu metropolitan area.

A Proposal of Direction of Wind Ventilation Forest through Urban Condition Analysis - A Case Study of Pyeongtaek-si - (도시 여건 분석을 통한 바람길숲 조성방향 제시 - 평택시를 사례로 -)

  • SON, Jeong-Min;EUM, Jeong-Hee;SUNG, Uk-Je;BAEK, Jun-Beom;KIM, Ju-Eun;OH, Jeong-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.101-119
    • /
    • 2020
  • Recently, as a plan to improve the particulate matter and thermal environment in the city, urban forests acting as wind ventilation corridor(wind ventilation forest) are promoted nationwide. This study analyzed the conditions for the creation of wind ventilation forest(vulnerable areas of the particulate matter and thermal environment, distribution of wind ventilation forest, characteristics of ventilation corridor) of in Pyeongtae-si, one of the target cities of wind ventilation forest project. Based on the results, the direction of developing on the wind ventilation forest in Pyeongtaek-si was suggested. As a result of deriving areas vulnerable to particulate matter and thermal environment, it was most vulnerable in urban areas in the eastern area of Pyeongtaek-si. Especially, emissions were high from industrial complexes and roads such as the Pyeongtaek-si thermal power plant, ports, and the national road no. 1. The wind ventilation forest in Pyeongtaek-si was distributed with small-scale windgenerating forests, wind-spreading forests, and wind-connection forests fragmented and disconnected. The characteristic of the overall wind ventilation corridor in Pyeongtaek-si is that the cold air generated from Mt.Mubong, etc., strongly flowed into Pyeongtaek-si and flowed in the northwest direction. Therefore, it is necessary to preserve and expand the wind-generating forests in Pyeongtaek-si in the long term, and it was important to create wind-spreading forests and wind-connection forests so that cold air could flow into the vulnerable area. In addition, in industrial complexes and roads where particulate matter is generated, planting techniques should be applied to prevent the spread of particulate matte to surrounding areas by creating wind-spreading forests considering the particulate matter blocking. This study can be used not only as the basis data for wind ventilation forest project in Pyeongtaek-si, but also as the basis data for urban forest creation and management.

Analysis of Natural Ventilation Characteristics of Venlo-type Greenhouse with Continuous Roof Vents (연속형 천창을 가진 벤로형 온실의 자연환기 특성 분석)

  • Kwon, Jin-Kyeong;Lee, Sung-Hyun;Seong, Jae-Hoon;Moon, Jong-Pil;Lee, Soo-Jang;Choi, Byeong-Min;Kim, Kyeong-Ja
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.444-452
    • /
    • 2011
  • In this study the characteristics of natural ventilation of Venlo-type greenhouse with continuous roof vents were analyzed using commercial computational fluid dynamics (CFD) code. Developed CFD simulation model was verified by comparison with experimental data. Simulation errors were 1.9-46.0% for air velocity and 1.7-11.2% for air temperature at each measurement point. CFD simulations were conducted to estimate the effect of roof vents opening direction, opening angle, outside wind velocity and wind directions on ventilation rate and climate condition in greenhouse. The results of this study showed that ventilation rate of the present greenhouse was increased linearly in proportion to the increase of roof vent opening angle and outside wind velocity over 2.0 m/s. According to the analysis on the effects of different roof vent opening direction, simultaneous opening of wind and leeward vents showed the highest ventilation rate and lowest mean temperature in greenhouse.

A study on the working mechanism of internal pressure of super-large cooling towers based on two-way coupling between wind and rain

  • Ke, Shitang;Yu, Wenlin;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • v.70 no.4
    • /
    • pp.479-497
    • /
    • 2019
  • In the current code design, the use of a uniform internal pressure coefficient of cooling towers as internal suction cannot reflect the 3D characteristics of flow field inside the tower body with different ventilation rate of shutters. Moreover, extreme weather such as heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind. In this study, the world's tallest cooling tower under construction, which stands 210m, is taken as the research object. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed iteratively using continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind speed and rainfall intensity on the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower body is analyzed. The combination of wind velocity and rainfall intensity that is most unfavorable to the cooling tower in terms of distribution of internal pressure coefficient is identified. On this basis, the wind/rain loads, distribution of aerodynamic force and working mechanism of internal pressures of the cooling tower under the most unfavorable working condition are compared between the four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the amount of raindrops captured by the internal surface of the tower decreases as the wind velocity increases, and increases along with the rainfall intensity and ventilation rate of the shutters. The maximum value of rain-induced pressure coefficient is 0.013. The research findings lay the basis for determining the precise values of internal surface loads of cooling tower under extreme weather conditions.

On the Meteorological Influence on the Automobile Air Pollution in Daegu (대구지역 CO농도에 미치는 기상효과에 관한 연구)

  • 김해동;박명희;이정영
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.987-996
    • /
    • 2003
  • In this study, we analyzed the relationship between the time-variation trend of air pollution concentration index and the meteorological conditions with CO(carbon monoxide) concentration and meteorological observation data in high-CO episode days. CO is a representative automobile air pollutant. The results are as follows; 1. Most of the high-CO episode days within 30 classes appeared in winter season. 2. Most of them appeared under the surface weather conditions with east-west high-pressure system. The surface winds in this high-pressure area were very light. 3. The high-CO episode days were due to unusual accumulation within urban atmosphere in the morning. 4. The Atmospheric stabilities were more stable, and then the wind-ventilation conditions were worse than yearly mean atmospheric condition in Daegu.

Effects of Ventilation Condition and Ventilating Hole Sizes to Improve Quality Onion(Allium cepu. L) under Room Temperature (양파 간이저장시 통풍조건 및 통풍구 재료의 크기가 저장에 미치는 영향)

  • 이찬중;김희대;정은호;김우일;서전규
    • Food Science and Preservation
    • /
    • v.8 no.4
    • /
    • pp.356-361
    • /
    • 2001
  • This study was conducted to improve the storability of onion bulbs by assembly simple house storage and the reduce the rotteness caused by field open storage. Allium cepa cv. Changnyungdeago, late strain was used for the test at the storage condition of natural ventilation of levels 2, forced ventilation of levels 2, field open storage and 75mm, 100mm, and 125mm ventilating holes. Mean tamperature and relative humidity were not significantly different by ventilation conditions. Mean temperature was lower in forced ventilation than that of in natural ventilation and non-ventilation, and relative humidity was a little higher in ventilation treatment than those of the others. Weight loss of onion bulbs were 2.5%, 2.9%, 3%, 4.3% in field open storage, non ventilation, natural ventilation of levels 2 and forced ventilation of levels 2 respectively. Rotting rate in natural ventilation of levels 2 and farced ventilation of levels 2 were 27.7% and 25.4% respectively but 34.6% and 37.8% in non ventilation and field open storage. Therefore, the treatment of ventilation reduced the rotteness of storage onion bulbs. The smaller the size of a ventilating hole, the lower mean temperature was maintained. The relative humidity was some high in July, but didn’t showed significantly difference in August and September. With small size of a ventilating hole, the strong wind velocity was obtained, and wind velocity by position was weaker in the middle part than both ends. Rutting rates in 75㎜, 100㎜, and 125㎜ ventilating holes were 17.9%, 15.3% and 14.1% respectively.

  • PDF

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • v.27 no.1
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.

Effects of Method, Number of Times for Spraying and! Ventilation Condition on the Growth in Greenhouse (관수방법, 관수회수 및 송풍처리에 따른 초화류의 생장에 미치는 영향)

  • 민병로;김웅;이범선;이대원
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.149-155
    • /
    • 2004
  • On this study, a multipurpose operating system was developed to adjust a configuration of a moving path which have no connection with a form of greenhouse. To being performance the multipurpose working system, we have experienced growth quality on the plants in greenhouse. Some of the results are as follows. While watering by the hand spray. the condition of plant was generally no good. It was shown that plant height and leaf area were all high without wind during watering by the automatic spray. The effect to retrain a plant growth was high as a ventilation was strong. The diameter of a plant stem was small without ventilation condition during watering 3 times by automatic spray. The number of leaf was relatively large during 3 times by automatic spray compared to 2 times by automatic spray or hand spray. Growth of plant was fast as the times of spray were large.

Wind loading characteristics of super-large cooling towers

  • Zhao, L.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.13 no.3
    • /
    • pp.257-273
    • /
    • 2010
  • The aerodynamic and aero-elastic model tests of the China''s highest cooling tower has been carried out in the TJ-3 Boundary Layer Wind Tunnel of Tongji University. By adopting a scanivalve system, the external wind pressure is firstly measured on $12{\times}36$ taps for a single tower, two and four grouped towers under the condition of both smooth flow and the boundary layer due to surrounding geographic and building topography. The measurements of internal wind pressure distribution of $6{\times}36$ taps are taken for a single tower under the various ventilation ratios ranging from 0% to 100% of stuffing layers located at the bottom of the tower. In the last stage, the wind tunnel tests with an aero-elastic model are carefully conducted to determine wind-induced displacements at six levels (each with eight points) with laser displacement sensors. According to the measurement results of wind pressure or vibration response, the extreme aerodynamic loading values of the single or grouped towers are accordingly analyzed based on probability correlation technique.

Numerical Simulation on the Wind Ventilation Lane and Air Pollutants Transport due to Local Circulation Winds in Daegu Districts (대구지역의 국지순환풍의 환기경로 및 대기오염수송에 관한 수치모의)

  • Koo, Hyun-Suk;Kim, Hae-Dong
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.418-427
    • /
    • 2004
  • Recently, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane is widely practiced in many countries. The concept of urban ventilation lane is mainly aimed to improve the thermal comfort within urban area in summer season. It has also the aim to reduce the urban air pollution by natural cold air drainage flows which are to be intensified by a suitable alignment of buildings as well as use zonings based on scientific reasons. In this study, the prevailing wind ventilation lane of a local wind circulation and around Daegu for a typical summer days was investigated by using a numerical simulation. The transport of air pollutants by the local circulation winds was also investigated by using the numerical simulation model, the RAMS (Reasonal Atmospheric Model System).The domain of interest is the vicinity of Daegu metropolitan city (about 900 km2). The horizontal scale of the area is about 30 km. The simulations were conducted under a late spring synoptic condition with weak gradient wind and almost clear sky. From the numerical experiment, the following three conclusions were obtained: (1) The major wind passages of the local circulation wind generated by radiative cooling over the representative mountains of Daegu (Mt. Palgong and Mt. Ap) were found. The winds blow down along the valley axis over the eastern part of Daegu as a gravity flow during nighttime. (2) At the flatland, the winds blow toward the western part of Daegu through the city center. (3) As the results, the air pollutants were transported toward the western part of Daegu by the winds during nighttime.