• Title/Summary/Keyword: Wind ratio

Search Result 982, Processing Time 0.033 seconds

Effects of aspect ratio on laboratory simulation of tornado-like vortices

  • Tang, Zhuo;Zuo, Delong;James, Darryl;Eguch, Yuzuru;Hattori, Yasuo
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.111-121
    • /
    • 2018
  • Experiments were conducted in a large-scale Ward-type tornado simulator to study tornado-like vortices. Both flow velocities and the pressures at the surface beneath the vortices were measured. An interpretation of these measurements enabled an assessment of the mean flow field as well as the mean and fluctuating characteristics of the surface pressure deficit, which is a manifestation of the flow fluctuation aloft. An emphasis was placed on the effect of the aspect ratio of the tornado simulator on the characteristics of the simulated flow and the corresponding surface pressure deficit, especially the evolution of these characteristics due to the transition of the flow from a single-celled vortex to a two-celled vortex with increasing swirl ratio.

Peak Net Pressure Coefficients for Cladding Design of Retractable Dome Roofs according to Rise-Span Ratio (라이즈-스팬 비에 따른 개폐식 돔 지붕의 외장재 설계용 피크순압력계수)

  • Cheon, Dong-Jin;Kim, Yong-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.2
    • /
    • pp.101-109
    • /
    • 2024
  • In this study, the characteristics of wind pressure distribution on circular retractable dome roofs with a low rise-to-span ratio were analyzed under various approaching flow conditions by obtaining and analyzing wind pressures under three different turbulent boundary layers. Compared to the results of previous studies with a rise-to-span ratio of 0.1, it was confirmed that a lower rise-to-span ratio increases the reattachment length of the separated approaching flow, thereby increasing the influence of negative pressure. Additionally, it was found that wind pressures varied significantly according to the characteristics of the turbulence intensity. Based on these experimental results, a model for peak net pressure coefficients for cladding design was proposed, considering variations in turbulence intensity and height.

Critical Short Circuit Ratio Analysis on DFIG Wind Farm with Vector Power Control and Synchronized Control

  • Hong, Min;Xin, Huanhai;Liu, Weidong;Xu, Qian;Zheng, Taiying;Gan, Deqiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.320-328
    • /
    • 2016
  • The introduction of renewable energy sources into the AC grid can change and weaken the strength of the grid, which will in turn affect the stability and robustness of the doubly-fed induction generator (DFIG) wind farm. When integrated with weak grids, the DFIG wind turbine with vector power control often suffers from poor performance and robustness, while the DFIG wind turbine with synchronized control provides better stability. This paper investigates the critical short circuit ratios of DFIG wind turbine with vector power control and synchronized control, to analyze the stability boundary of the DFIG wind turbine. Frequency domain methods based on sensitivity and complementary sensitivity of transfer matrix are used to investigate the stability boundary conditions. The critical capacity of DFIG wind farm with conventional vector power control at a certain point of common coupling (PCC) is obtained and is further increased by employing synchronized control properly. The stability boundary is validated by electromagnetic transient simulation of an offshore wind farm connected to a real regional grid.

Conceptual Design Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 풍동 개념연구)

  • Kang, Seung-Hee;Choi, Woo-Ram;Kim, Hae-Jeong;Kim, Yong-Hwi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.431-434
    • /
    • 2009
  • Conceptual study of an open-circuit type low-speed wind tunnel for test of wind turbine blade is conducted. The tunnel is constituted of a settling chamber, a contraction, closed and open test sections, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The open test section with dimension width of 1.8 m, height of 1.8 m and length of 4.14 m is adopted for aeroacoustic test. The contraction ratio is 9 to 1 and maximum speed in the closed test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine.

  • PDF

Comparison of Load Ratio of Load-cell type Anemometer with Windswept Shape Variation (수풍부 형상에 따른 로드 셀형 풍향풍속계의 하중 비 비교)

  • Kim, Tae-Hyeong;Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.36 no.10
    • /
    • pp.839-844
    • /
    • 2012
  • Anemometer is a meteorological instrument that measures wind direction and wind speed in real time, and is mounted to the cranes that are used at ports, shipbuilding yards, off-shore structure, or construction sites that are influenced by wind, and it is used in conjunction with the safety system. Load cell-type anemometer measures the wind direction through the ratio of load between 4 positions by mounting the thin plate to 4 load cells, and measures wind velocity through the summation of loads. According to previous research, the load ratio between two adjacent windswept with respect to the wind direction has unstable value due to vortex around windswept. This causes the result that increases an error on the wind direction. In this study we compared and analyzed the difference between the load ratio with respect to three type windswept shapes in order to suggest the proper windswept shape to reduce this error. The computational fluid flow analysis is carried out with ANSYS CFX to analyze the load ratio between three windswept shapes. Wind direction was adopted as the design variable, and selected 9 wind direction conditions from $0^{\circ}{\sim}90^{\circ}$ with $11.25^{\circ}$ interval for computational fluid flow analysis.

Wind Turbine Performance for Eigen Value Change of Pitch Controller (피치제어기의 고유치 변화에 따른 풍력발전기의 성능)

  • Kim, Jong-Hwa;Moon, Seok-Jun;Shin, Yun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.337-343
    • /
    • 2012
  • NREL(National Renewable Energy Laboratory) Baseline controller conduct using method proposed RISO National Laboratory in Region 3. which designed the blade-pitch control system using a single degree-of-freedom model of the wind turbine. Idealized PID-Controlled rotor-speed error will respond as a second-order system with the natural frequency and damping ratio. RISO proposed specific natural frequency(=0.6 rad/s) and damping ratio(=0.7). If specific Eigen value apply to NREL 5 MW wind turbine, differ with pitch respond for simulation results of RISO report. Variation of specific eigen value investigate performance of NREL 5 MW wind turbine.

  • PDF

Wind Speed Estimation using Regression Method for Maximum Power Control (리그레션 방법을 이용한 최대출력제어 풍속예측)

  • Ko, SeungYoun;Kim, Ho-Chan;Huh, Jong-Chul;Kang, Min-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.327-333
    • /
    • 2015
  • Wind turbines, in the case of less than rated wind speed, is controlled to achieve maximum power. MPC(Maximun Power Control) method, by controlling the rotational speed of the generator, is a method to achieve maximum power but should know the wind speed. However, for several reasons, there have been proposed methods of estimating the wind speed rather than measuring wind speed. TSR(Tip Speed Ratio) is needed to know to estimate the wind speed. However, a complex interaction formula has to be solved to find a TSR. Therefore, many methods have been suggested to solve a complex interaction formula. In this paper, the new method has been proposed to simplify the complicated interaction formula by using the regression method. Matlab/Simulink is used to simulate and to verify the proposed method.

Fluctuating Wind Pressures on High Aspect Ratio Circular Cylinder

  • Keisuke Miura;Masahiro Matsui
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.277-286
    • /
    • 2022
  • In this study, The POD technique was applied to the fluctuating wind pressure of high aspect ratio circular cylinder to consider about its organizational structure, and considered about the characteristics of the fluctuating wind force obtained by synthesized the POD modes.

A Study on Green Space Management Planning Considering Urban Thermal Environment (도시 열환경을 고려한 녹지관리방안 수립 연구)

  • Joo, Chang-Hun;Kim, Jeong-Ho;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1349-1358
    • /
    • 2014
  • This study suggests plan of green space management based on the result of research apprehending the characteristic through sorting types of city thermal environment targeting summer which thermal pollution is the most serious. Considering anthropogenic heat, development level of wind road, thermal environment, as a result of types of thermal environment process, it is appeared 36 types, and 10 types is relevant of this research subject. Type I-1, size of building is large, artificial covering area is wide, and thermal load of anthropogenic heat is high, type II-1, development condition of wind road is incomplete as IIlevel, entering cold air is difficult and thermal management and improvement is needed area. Type III-1, scale is large and it is area of origin of cold air, development level of wind road is mostly favorable, type III-2 is revealed as smaller scale than III-1, and small area of origin of cold air. Type IV, anthropogenic heat is $81{\sim}150W/m^2$, average, but development function of wind road is very favorable. Type V, large area of thermal load and the origin of cold air are distributed as similar ratio, and level of development function of wind road is revealed as II level. According to standard of type classification of thermal environment, as a result of suggesting plan of green space management and biotops area ratio, type I-1 is buffer green space and waterway creation, goal biotops area ratio 35%, type II-1 afforestation in site and goal biotops area ratio 40%, type III-1, preservation plan to display the current function continuously is requested. Type IV suggests afforestation of stream current, and type V suggests quantitative increase of green space and goal biotops area ratio 45%.

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.