• Title/Summary/Keyword: Wind Ventilation Corridor

Search Result 15, Processing Time 0.023 seconds

Air Ventilation Evaluation at Nighttime for the Construction of Wind Corridor in Urban Area (도시지역의 바람길 조성을 위한 야간시간대의 공기순환성 평가)

  • Song, Bong-Geun;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.2
    • /
    • pp.16-29
    • /
    • 2013
  • The purpose of this study is to evaluate air ventilation using wind patterns of MetPhoMod program at nighttime focused on Changwon-si, Gyeongsangnam-do. Evaluation indices of air ventilation are wind resistant and retention used by results of each wind speed and diversity. The results are as follows. Vulnerable areas of air ventilation are Bonglim-dong, Bansong-dong, Yongji-dong and so on. In high-rise apartment, commercial area and single residential area of Yongji-dong, Sangnam-dong and Sapa-dong, wind is stagnated by high buildings. Therefore, these areas should construct urban spaces to circulate the wind. And to inflow persistingly the fresh wind generated in a rural area, we think that the construction of wind corridor is suggested by development plan and policy wind corridor.

A Proposal of Direction of Wind Ventilation Forest through Urban Condition Analysis - A Case Study of Pyeongtaek-si - (도시 여건 분석을 통한 바람길숲 조성방향 제시 - 평택시를 사례로 -)

  • SON, Jeong-Min;EUM, Jeong-Hee;SUNG, Uk-Je;BAEK, Jun-Beom;KIM, Ju-Eun;OH, Jeong-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.4
    • /
    • pp.101-119
    • /
    • 2020
  • Recently, as a plan to improve the particulate matter and thermal environment in the city, urban forests acting as wind ventilation corridor(wind ventilation forest) are promoted nationwide. This study analyzed the conditions for the creation of wind ventilation forest(vulnerable areas of the particulate matter and thermal environment, distribution of wind ventilation forest, characteristics of ventilation corridor) of in Pyeongtae-si, one of the target cities of wind ventilation forest project. Based on the results, the direction of developing on the wind ventilation forest in Pyeongtaek-si was suggested. As a result of deriving areas vulnerable to particulate matter and thermal environment, it was most vulnerable in urban areas in the eastern area of Pyeongtaek-si. Especially, emissions were high from industrial complexes and roads such as the Pyeongtaek-si thermal power plant, ports, and the national road no. 1. The wind ventilation forest in Pyeongtaek-si was distributed with small-scale windgenerating forests, wind-spreading forests, and wind-connection forests fragmented and disconnected. The characteristic of the overall wind ventilation corridor in Pyeongtaek-si is that the cold air generated from Mt.Mubong, etc., strongly flowed into Pyeongtaek-si and flowed in the northwest direction. Therefore, it is necessary to preserve and expand the wind-generating forests in Pyeongtaek-si in the long term, and it was important to create wind-spreading forests and wind-connection forests so that cold air could flow into the vulnerable area. In addition, in industrial complexes and roads where particulate matter is generated, planting techniques should be applied to prevent the spread of particulate matte to surrounding areas by creating wind-spreading forests considering the particulate matter blocking. This study can be used not only as the basis data for wind ventilation forest project in Pyeongtaek-si, but also as the basis data for urban forest creation and management.

Analysis Schemes of Wind Ventilation Forest Types - A Case Study of Daegu Metropolitan City - (바람길숲의 유형별 분석 방안 - 대구광역시를 사례로 -)

  • EUM, Jeong-Hee;OH, Jeong-Hak;SON, Jeong-Min;KIM, Kwon;BAEK, Jun-Beom;YI, Chaeyeon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.12-23
    • /
    • 2019
  • This study aims to suggest analysis schemes of urban forests acting as wind ventilation corridor(wind ventilation forest). For this purpose, wind corridor forests were classified into three types: wind-generating forests(WGF), wind-spreading forests (WSF), and wind-connecting forests(WCF), and they were classified into three grades. WGF, WSF and WCF were classified based on the density of forest type map, vegetation index, and ventilation networks, respectively. As a result of analyzing wind corridor forests for Daegu Metropolitan City(883.56㎢), the area of WGF was classified as 443.1㎢ and distributed in the northern and southern regions of Daegu Metropolitan City. Among them, the first grade of WGF occupied the largest area(345.59㎢) and the highest rate(54.44%) in Dalseong-gun. On the other hand, WGF was not found in Jung-gu, because this administrative district is isolated from the forest area. WSF was 32.4㎢, which included representative urban parks of Daegu Metropolitan City, and WSF were found relatively much in Suseong-gu and Dalseong-gun. However, WSF were distributed throughout Metropolitan City, and the vegetation index was not high. The ventilation network that can form WCF included major rivers and roads in Daegu Metropolitan City, but this network was not connected to the urban park from the outer forest. Therefore, it was judged that the formation of WCF connecting WGF outside the city and WSF inside the city would be important. The results of this study can be used as a basic data for systematic wind corridor forest projects, and can be used as basic data for establishing guidelines for wind corridor forest analysis at national and local levels.

Analysis and Utilization Strategies of Ventilation Corridor Characteristics in Jeon-ju Area (전주지역의 바람길 특성 분석 및 활용 방안)

  • Eum, Jeong-Hee
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.3
    • /
    • pp.366-374
    • /
    • 2019
  • This study aims to analyze the characteristics of ventilation corridor and propose its utilization strategies in Jeonju city in order to discuss how to utilize urban ventilation corridors as a planning factor for reducing heat wave impact and fine particle pollution. For these purposes, cold air characteristics such as cold air flow and height of cold air in Jeonju area located in the Honam Jeongmaek were analyzed and major ventilation corridors were specified. Based on them, we proposed mountain management strategies for securing and utilizing ventilation corridors. We used KALM (Kaltluftabflussmodell), a cold air simulation model developed in Germany and identified both the cold air flow and the height of cold air layer generated during 6 hours at night. As a result, the cold air flow generated in the forests located in the northeast and east sides of the Jeonju city became clear and the height of cold air layer increased in the valley terrain and farmland areas with time. In particular, Jeonju City has an ideal structure of urban ventilation corridor. Based on the results, the area where the cold air generation is active was designated as the 'cold air conservation area', and the area requiring the management for the good cold air flow was as the 'cold air management area'. This study is expected to be used as basic data of policy making and research for reducing heat wave impact and fine particle pollution such as climate change adaptation policy and urban forest plans for ventilation corridor composition.

Application of Ventilation Corridor to Mitigate Particulate Matter for the Sejong-Si (미세먼지 저감대책으로서 바람길 적용 방안 : 세종시를 대상으로)

  • Nam, Seongwoo;Sung, Sunyong;Park, Jong-Soon
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2020
  • The purpose of this study is to verify the effects of ventilation corridor and derive adequate policy alternatives to its application for the city of Sejong, which is located in an inland of Korean Peninsula. In order to introduce the ventilation corridor in the city, it is necessary both to understand change on fresh air flow affected by the construction of new cities and to show its effects which are able to circulate air flow of the city. The study identified ventilation effects using computational fluid dynamics models. In particular, it analyzed change on wind speed and direction after constructing of a new town and cool air flow along the lowlands generated after sunset. In addition, it identified those of reducing particulate matter when arranging buildings conforming to the ventilation corridor at block level. The policy implications derived from simulation can be summarized as follows. First, it is desirable to plan ventilation corridors so that fresh air from mountains, forests, and valleys can flow into cities and mitigate the concentration of particulate matter. Furthermore, public facilities covering parks, plazas, and playgrounds should be installed preferentially to attract safe outdoor activities near to areas with low levels of particulate matter. Finally, it is adequate to prepare for a number of alternative plans by analyzing ventilation corridors when setting out district unit plan.

Strategies for utilizing Urban Ventilation Corridor considering Local Cold Air in Watershed Areas - A Case Study of Uijeongbu and Gwacheon - (유역의 찬공기 특성을 고려한 도시 바람길 활용 전략 - 경기도 의정부 및 과천 일대를 사례로 -)

  • EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.133-151
    • /
    • 2019
  • This study aims to analyze cold air characteristics in the watershed areas and to suggest strategies for utilizing them in urban ventilation corridor plans. For this purpose, the Jungnangcheon watershed and Uijeongbu-si in the northern part of Gyeonggi province, and Anyangcheon watershed as well as Yangjaecheon Tancheon watershed and Gwacheon-si in the southern part were selected as study areas. We used KALM (Kaltluftabflussmodell), a cold air simulation model developed in Germany and identified both the cold air flow and the height of cold air layer generated during 6 hours at night. Uijeongbu City is located on the main stream of the Jungnangcheon watershed, and the local cold air from the southern outskirts is an important part of Uijeongbu-si's overall ventilation corridor planning. In addition, the cold air generated in the vicinity of Mt. Sapae flows into the central business district near the city hall and plays a major role in regulating the thermal environment of the city. But, the cold air flows in the eastern part of Uijeongbu-si was not smoothly. The cold air flow generated in the east of Gwanak Mountain and in the west of Cheonggye Mountain was the most active in the northern part of Gwacheon-si. This flow is also a major ventilation corridor in Anyangcheon watershed as well as Yangjaecheon Tancheon watershed. But, the southern part where the cold air flow is not smooth is planed to be developed as 'Gwacheon Knowledge Information Town Public Housing District', so rapid development is expected in the future. Hence, it is suggested that an additional ventilation corridor plan should be established based on the detailed local wind flow analysis.

A Study on the Effectiveness of Wind Corridor Construction forImproving Urban Thermal Environment: A Case study of Changwon, South Korea (도시 열환경 개선을 위한 취약지역 선정 및 바람길 조성 방안: 창원시를 대상으로)

  • Kim, Jong-Sung;Kang, Jung-Eun
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.4
    • /
    • pp.187-202
    • /
    • 2021
  • This study examined the effectiveness of wind corridor construction by analyzing the thermal environment, cold air generation, ventilation, and geographical characteristics to improve urban thermal environment and establish the basis for specialized strategy in Changwon-si, Gyeongsangnam-do. Using spatial analysis and remote sensing techniques, surface temperature, land cover and land use, wind field, and slope were measured and through this, a wind corridor analysis model was constructed. As a result of the analysis as of 2020, Changwon-si generally has land cover characteristics that are advantageous for the generation of cold air, but the temperature in most urban areas is the highest, and the temperature in areas such as north Changwon area, Jinbukmyeon, Ung-dong, and Ungcheon-dong are relatively high. There was a typical trend of high average wind speed in mountain regions and low average wind speed in urban areas. Accordingly, the north Changwon area, the former Changwon downtown area, the Hogye-ri and Pyeongseong-ri areas, and the Changpo Bay area are derived as vulnerable areas to thermal environment, and various measures to reduce temperature and improve air quality that the inflow of cold air into the area considering the characteristics of each area and securing wind ventilation between the surrounding mountains, reservoirs, and park areas were proposed.

Building Wind Corridor Network Using Roughness Length (거칠기길이를 이용한 바람통로 네트워크 구축)

  • An, Seung Man;Lee, Kyoo-Seock;Yi, Chaeyeon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.101-113
    • /
    • 2015
  • The purpose of this study is increasing ventilation network usability for urban green space planning by enhancing its practicality and detail. A ventilation network feature extraction technique using roughness length($z_0$) was proposed. Continuously surfaced DZoMs generated from $z_0$(cadastral unit) using three interpolations(IDW, Spline, and Kriging) were compared to choose the most suitable interpolation method. Ventilation network features were extracted using the most suitable interpolation technique and studied with land cover and land surface temperature by spatial overlay comparison. Results show Kriging is most suitable for DZoM and feature extraction in comparison with IDW and Spline. Kriging based features are well fit to the land surface temperature(Landsat-7 ETM+) on summer and winter nights. Noteworthy is that the produced ventilation network appears to mitigate urban heat loads at night. The practical use of proposed ventilation network features are highly expected for urban green space planning, though strict validation and enhancement should follow. (1) $z_0$ enhancement, (2) additional ventilation network interpretation and editing, (3) linking disconnected ventilation network features, and (4) associated dataset enhancement with data integrity should technically preceded to enhance the applicability of a ventilation network for green space planning. The study domain will be expanded to the Seoul metropolitan area to apply the proposed ventilation network to green space planning practice.

Environmental Planning Contermeasures Considering Spatial Distribution and Potential Factors of Particulate Matters Concentration (미세먼지 농도의 공간적 현황 및 잠재영향인자를 고려한 환경계획적 대응 방향)

  • Sung, Sun-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.1
    • /
    • pp.89-96
    • /
    • 2020
  • Adverse impact of Particulate Matters(PM10, PM2.5; PMs) significantly affects daily lives. Major countermeasures for reducing concentration of PMs were focused on emission source without considering spatial difference of PMs concentration. Thus, this study analyzed spatial·temporal distribution of PMs with observation data as well as potential contributing factors on PMs concentration. The annual average concentration of PMs have been decreased while the particulate matter warnings and alerts were significantly increased in 2018. The average concentration of PMs in spring and winter was higher than the other seasons. Also, the spatial distribution of PMs were also showed seasonality while concentration of PMs were higher in Seoul-metropolitan areas in all seasons. Climate variables, emission source, spatial structure and potential PM sinks were selected major factors which could affects on ambient concentrations of PMs. This paper suggest that countermeasures for mitigating PM concentration should consider characteristics of area. Climatic variables(temperature, pressure, wind speed etc.) affects concentrations of PMs. The effects of spatial structure of cities(terrain, ventilation corridor) and biological sinks(green infrastructure, urban forests) on concentration of PMs should be analyzed in further studies. Also, seasonality of PMs concentration should be considered for establishing effective countermeasures to reduce ambient PMs concentration.

Air Temperature Decreasing Effects by Shading and Ventilation at Micro-scale Experiment Plots (소공간 실험구의 차광과 통풍에 의한 기온저감 효과)

  • Kim, Hyun-Cheol;Woo, Ji-Keun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.6
    • /
    • pp.39-48
    • /
    • 2010
  • The purpose of this study was to analyze air temperature decreasing effects by shading and ventilation at micro-scale experiment plots, especially focused on the Wet Bulb Globe Temperature (WBGT) in outdoor spaces. To monitor the time-serial changes of Dry-bulb Temperature (DT), Globe Temperature (GT) and Relative Humidity (RH) in the wind blocking and shading conditions, Two hexahedral steel frames were established on the open grass field, the dimension of each frame was 1.5m(W)${\times}$1.5m(L)${\times}$1.5m(H). Four vertical side of one frame was covered by transparent polyethylene film to prevent wind passing through (Wind break plot; WP). The top side of the other frame was covered with shading curtain which intercept 95% of solar light and energy (Shading plot; SP). And, Another vertical steel frame without any treatment preventing ventilation and sunlight was set up, which represents natural conditions (Control plot; CP). The major findings were as follows; 1. The average globe temperature (GT) was highest at WP showing $50.94^{\circ}C$ and lowest at SP showing $34.58^{\circ}C$. The GT of natural condition (SP) was $42.31^{\circ}C$ locating the midst between WP and SP. The difference of GT of each plot was about $8-16^{\circ}C$, which means the ventilation and shading has significant effect on decreasing the temperature. 2. WP showed the highest average dry-bulb temperature (DT) of $38.41^{\circ}C$ which apparently differ from SP and CP showing $31.94^{\circ}C$ and $33.15^{\circ}C$ respectively. The DT of SP and CP were nearly the same. 3. The average relative humidity (RH) was lowest at WP showing 15.21%, but SP and CP had similar RH 28.79%, 28.02% respectively. 4. The average of calculated WBGT were the highest at the WP ($27.61^{\circ}C$) and the lowest at the SP ($23.64^{\circ}C$). The CP ($25.49^{\circ}C$) was in the middle of the others. As summery, compared with natural condition (CP), the wind blocking increased about $2.11^{\circ}C$ WBGT, but the shading decreased about $1.84^{\circ}C$ WBGT. So It can be apparently said that the open space with much shading trees, sheltering furnitures and well-delivered wind corridor can reduce useless and even harmful energy for human outdoor activity considerably in outdoor spaces.