• 제목/요약/키워드: Wind Turbulence

검색결과 614건 처리시간 0.021초

Proper orthogonal decomposition in wind engineering - Part 1: A state-of-the-art and some prospects

  • Solari, Giovanni;Carassale, Luigi;Tubino, Federica
    • Wind and Structures
    • /
    • 제10권2호
    • /
    • pp.153-176
    • /
    • 2007
  • The Proper Orthogonal Decomposition (POD) is a statistical method particularly suitable and versatile for dealing with many problems concerning wind engineering and several other scientific and humanist fields. POD represents a random process as a linear combination of deterministic functions, the POD modes, modulated by uncorrelated random coefficients, the principal components. It owes its popularity to the property that only few terms of the series are usually needed to capture the most energetic coherent structures of the process, and a link often exists between each dominant mode and the main mechanisms of the phenomenon. For this reason, POD modes are normally used to identify low-dimensional subspaces appropriate for the construction of reduced models. This paper provides a state-of-the-art and some prospects on POD, with special regard to its framework and applications in wind engineering. A wide bibliography is also reported.

능동 요 제어 알고리즘의 비교 연구 (Comparative Study on Active Yaw Control Algorithms)

  • 최한순;이호철;방조혁
    • 풍력에너지저널
    • /
    • 제10권3호
    • /
    • pp.5-11
    • /
    • 2019
  • This paper suggests and compares two algorithms, a moving average filter method and a method developed by the National Renewable Energy Laboratory (NREL), to verify the yaw control algorithm characteristic to reduce yaw error for a wind turbine. A characteristic change for yaw movement in accordance with control parameter change that consists of each control method has been verified. Also, yaw simulations were performed using nacelle wind data measured from two areas with different turbulence intensities and the yaw movement data in each area was compared. These two algorithms and real data were compared by calculating mean absolute error (MSE) and the number of yawing (NY). As a result of the analysis, the MSE values were not significantly different between the two algorithms, but the algorithm proposed by the NREL was found to reduce yaw movement by up to 50 percent more than the moving average filter method.

천이영역에서 난류에너지의 이동에 관한 실험적 연구 (An Experimental Study on the Transport of Turbulent Energy in the Transitional Boundary Layer)

  • 임효재;백성구;이원근
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.131-138
    • /
    • 2003
  • 본 연구에서는 평판 경계층의 천이 영역에서 평균속도, 표면마찰계수, 간헐도 분포, 에너지 스펙트럼 등의 신뢰성 있는 실험 자료를 획득하였다. 실험 결과 천이가 진행됨에 따라 난류반점이 지배하는 영역이 벽면 근처에서 전 경계층으로 확산되었으며 이러한 현상의 결과로 속도 섭동량에서 비등방성이 크게 나타난다. 천이 이전영역에서는 에너지가 주로 저주파에 집중되어 있다가 천이를 거치면서 에너지가 고주파 성분으로 이동하였다 이는 두 가지 이상의 에너지 발생과 소멸 메커니즘이 천이영역에서 공존하고 있음을 의미한다. 따라서 천이영역에서의 유동장을 예측하기 위한 난류 계산 모형에서 비등방성과 서로 다른 메커니즘을 표현할 수 있기 위해서는 반드시 두 가지 이상의 척도를 표현할 수 있어야 한다.

Wind-induced dynamic response and its load estimation for structural frames of circular flat roofs with long spans

  • Uematsu, Yasushi;Yamada, Motohiko
    • Wind and Structures
    • /
    • 제5권1호
    • /
    • pp.49-60
    • /
    • 2002
  • This paper describes a simple method for evaluating the design wind loads for the structural frames of circular flat roofs with long spans. The dynamic response of several roof models were numerically analyzed in the time domain as well as in the frequency domain by using wind pressure data obtained from a wind tunnel experiment. The instantaneous displacement and bending moment of the roof were computed, and the maximum load effects were evaluated. The results indicate that the wind-induced oscillation of the roof is generally dominated by the first mode and the gust effect factor approach can be applied to the evaluation of the maximum load effects. That is, the design wind load can be represented by the time-averaged wind pressure multiplied by the gust effect factor for the first mode. Based on the experimental results for the first modal force, an empirical formula for the gust effect factor is provided as a function of the geometric and structural parameters of the roof and the turbulence intensity of the approach flow. The equivalent design pressure coefficients, which reproduce the maximum load effects, are also discussed. A simplified model of the pressure coefficient distribution is presented.

Wind characteristics of Typhoon Dujuan as measured at a 50m guyed mast

  • Law, S.S.;Bu, J.Q.;Zhu, X.Q.;Chan, S.L.
    • Wind and Structures
    • /
    • 제9권5호
    • /
    • pp.387-396
    • /
    • 2006
  • This paper presents the wind characteristics of Typhoon Dujuan as measured at a 50 m guyed mast in Hong Kong. The basic wind speed, wind direction and turbulent intensity are studied at two measurement levels of the structure. The power spectral density of the typhoon is compared with the von Karman prediction, and the coherence between wind speeds at the two measurement levels is found to This paper presents the wind characteristics of Typhoon Dujuan as measured at a 50 m guyed mast in Hong Kong. The basic wind speed, wind direction and turbulent intensity are studied at two measurement levels of the structure. The power spectral density of the typhoon is compared with the von Karman prediction, and the coherence between wind speeds at the two measurement levels is found to compare with Davenport's prediction. The effect of typhoon Dujuan on the response of the structure will be discussed in a companion paper (Law, et al. 2006).with Davenport's prediction. The effect of typhoon Dujuan on the response of the structure will be discussed in a companion paper (Law, et al. 2006).

Field measurement results of Tsing Ma suspension Bridge during Typhoon Victor

  • Xu, Y.L.;Zhu, L.D.;Wong, K.Y.;Chan, K.W.Y.
    • Structural Engineering and Mechanics
    • /
    • 제10권6호
    • /
    • pp.545-559
    • /
    • 2000
  • A Wind and Structural Health Monitoring System (WASHMS) has been installed in the Tsing Ma suspension Bridge in Hong Kong with one of the objectives being the verification of analytical processes used in wind-resistant design. On 2 August 1997, Typhoon Victor just crossed over the Bridge and the WASHMS timely recorded both wind and structural response. The measurement data are analysed in this paper to obtain the mean wind speed, mean wind direction, mean wind inclination, turbulence intensity, integral scale, gust factor, wind spectrum, and the acceleration response and natural frequency of the Bridge. It is found that some features of wind structure and bridge response are difficult to be considered in the currently used analytical process for predicting buffeting response of long suspension bridges, for the Bridge is surrounded by a complex topography and the wind direction of Typhoon Victor changes during its crossing. It seems to be necessary to improve the prediction model so that a reasonable comparison can be performed between the measurement and prediction for long suspension bridges in typhoon prone regions.

Computational evaluation of wind loads on a standard tall building using LES

  • Dagnew, Agerneh K.;Bitsuamlak, Girma T.
    • Wind and Structures
    • /
    • 제18권5호
    • /
    • pp.567-598
    • /
    • 2014
  • In this paper, wind induced aerodynamic loads on a standard tall building have been evaluated through large-eddy simulation (LES) technique. The flow parameters of an open terrain were recorded from the downstream of an empty boundary layer wind tunnel (BLWT) and used to prescribe the transient inlet boundary of the LES simulations. Three different numerically generated inflow boundary conditions have been investigated to assess their suitability for LES. A high frequency pressure integration (HFPI) approach has been employed to obtain the wind load. A total of 280 pressure monitoring points have been systematically distributed on the surfaces of the LES model building. Similar BLWT experiments were also done to validate the numerical results. In addition, the effects of adjacent buildings were studied. Among the three wind field generation methods (synthetic, Simirnov's, and Lund's recycling method), LES with perturbation from the synthetic random flow approach showed better agreement with the BLWT data. In general, LES predicted peak wind loads comparable with the BLWT data, with a maximum difference of 15% and an average difference of 5%, for an isolated building case and however higher estimation errors were observed for cases where adjacent buildings were placed in the vicinity of the study building.

녹색섬 풍력자원평가 - 독도 (Wind Resource Assessment for Green Island - Dokdo)

  • 김현구;김건훈;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.94-101
    • /
    • 2012
  • A Dokdo wind resource map has been drawn up for the Green Island Energy Master Plan according to Korea's national vision for 'Low Carbon Green Growth'. The micro-siting software WindSim v5.1,which is based on Computational Flow Analysis, is used with MERRA reanalysis data as synoptic climatology input data, and sensitivity analysis on turbulence model is accompanied. A wind resource assessment has been conducted for the Dokdo wind power dissemination plan, which consists of two 10kW wind turbines to be installed at the Dongdo dock and Dokdo guard building. It is evaluated that the capacity factors at Dongdo dock and Dokdo guard building are about 20% and 30% respectively, and annual and hourly variations of wind power generation have been analyzed, but summertime energy production is predicted to be only 40% of wintertime energy production.

Analysis and performance of offshore platforms in hurricanes

  • Kareem, Ahsan;Kijewski, Tracy;Smith, Charles E.
    • Wind and Structures
    • /
    • 제2권1호
    • /
    • pp.1-23
    • /
    • 1999
  • Wind effects are critical considerations in the design of topside structures, overall structural systems, or both, depending on the water depth and type of offshore platform. The reliable design of these facilities for oil fields in regions of hostile environment can only be assured through better understanding of the environmental load effects and enhanced response prediction capabilities. This paper summarizes the analysis and performance of offshore platforms under extreme wind loads, including the quantification of wind load effects with focus on wind field characteristics, steady and unsteady loads, gust loading factors, application of wind tunnel tests, and the provisions of the American Petroleum Institute Recommended Practice 2A - Working Stress Design (API RP 2A-WSD) for the construction of offshore structures under the action of wind. A survey of the performance of platforms and satellite structures is provided, and failure mechanisms concerning different damage scenarios during Hurricane Andrew are examined. Guidelines and provisions for improving analysis and design of structures are addressed.

농업시설의 환기효율성연구를 위한 풍동경계층 설계 (Design of Wind and Turbulence Profiles in a Wind Tunnel for Study of Ventilation Efficiency of Agricultural Buildings)

  • 이인복;최규홍;전종길;김경원
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2003년도 하계 학술대회 논문집
    • /
    • pp.366-371
    • /
    • 2003
  • 농촌지역의 인구가 급속히 감소하고 있는 가운데, 농촌인력의 노약화, 여성화가 매우 빠르게 진행되고 있다. 인력을 효율적으로 이용하고 농업생산성을 높이기 위하여 현재 온실, 축사 등 농업시설은 자동화, 대형화되어 가고 있는 추세에 있다. 이러한 농업시설의 대형화에 따른 최적환경조성의 중요성이 대두되고 있어서 이에 따른 적합한 시설환경이 요구되고 있으나 적정환기가 이루어지지 않아 생산성 향상에 어려움이 많이 있다. (중략)

  • PDF