• Title/Summary/Keyword: Width-to-height

Search Result 2,413, Processing Time 0.028 seconds

Analysis of Kinematics and Kinetics According to Skill Level and Sex in Double-under Jump Rope Technique

  • Kim, Dae Young;Jang, Kyeong Hui;Lee, Myeoung Gon;Son, Min Ji;Kim, You Kyung;Kim, Jin Hee;Youm, Chang Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.171-179
    • /
    • 2017
  • Objective: The purpose of this study was to perform a kinematic and kinetic analysis of double-under jump rope technique according to skill level and sex. Method: Participants comprised a skilled group of 16 (9 males, 7 females), and an unskilled group of 16 with 6 months or less of experience (9 males, 7 females). Five consecutive double-under successes were regarded as 1 trial, and all participants were asked to complete 3 successful trials. The data for these 3 trials were averaged and analyzed after collecting the stable third jump in each trial. The variables used in the analysis included phase duration, total duration, flight time, vertical toe height, stance width, vertical center of mass displacement, and right lower limb ankle, knee, and hip joint angles in the sagittal plane during all events. Results: The skilled group had a shorter phase and total duration and a shorter flight time than the unskilled group. The vertical center of mass displacement and ankle dorsiflexion angle were significantly smaller in the skilled group. The male group had a shorter phase duration than the female group. The vertical toe height was greater, the stance width was smaller, and the ankle and hip flexion angles were smaller in the male group. Conclusion: Variables that can be used to distinguish between skill levels are phase and total duration, flight time, vertical center of mass displacement, and ankle dorsiflexion angle. Differences between sexes in double-under jump rope technique may be related to lower limb flexion angle control.

Correction of Pincer Nail using Autogenous Dermofat Graft (자가 진피지방술을 이용한 집게조갑의 교정)

  • Kim, Hyun-Sung;Kim, Chul-Han;Kang, Sang-Gue;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.250-255
    • /
    • 2010
  • Purpose: Pincer nail is a relatively rare deformity characterized by an increase in transverse curvature along the longitudinal axis of the nail. This curvature commonly increases from proximal to distal end of nail, leading to pinching, curling, and distortion of the underlying soft tissue and resulting frequently in severe pain. Numerous surgical procedures have been reported. Preserving the width of the nail in the correction of the pincer nail is very important for functional and aesthetic reasons. We report the results of the correction of the pincer nail using autogenous dermofat graft with a good result. Methods: From May 2006 to September 2008, dermofat graft was performed in 6 patients with pincer nail. Patients were four women and two men, and the average age was 51. The affected digits were the unilateral great toes in four patients and the unilateral thumbs in two patients. Average follow-up period was 13 months. Surgical procedure was removal of nail using an elevator to avoid damage to the nail bed. An incision was created in distal portion of hyponychium. Paronychium was dissected from distal phalanx by periosteal elevator through incision of hyponychium and tunnel was made. Then dermofat grafts harvested from inguinal area were inserted into the tunnel. Finally, a silicone sheet was inserted eponychial fold for prevention of synechia. Objective assessment was evaluated by use of the width index and height index. Results: All patients reported resolution of the pain and soft tissue pinching sensation that they had before the operation. There was good adherence between the nail plate and the underlying nail bed. The nails have regrown and were corrected in a normal and flattened appearance. The width index and height index were improved. Conclusion: The autogenous dermofat graft seems to provide an effective treatment of the pincer nail with preservation of the nail matrix.

Development of Computer Vision System for Individual Recognition and Feature Information of Cow (II) - Analysis of body parameters using stereo image - (젖소의 개체인식 및 형상 정보화를 위한 컴퓨터 시각 시스템 개발(II) - 스테레오 영상을 이용한 체위 분석 -)

  • 이종환
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.65-76
    • /
    • 2003
  • The analysis of cow body parameters is important to provide some useful information fur cow management and cow evaluation. Present methods give many stresses to cows because they are invasive and constrain cow postures during measurement of body parameters. This study was conducted to develop the stereo vision system fur non-invasive analysis of cow body features. Body feature parameters of 16 heads at two farms(A, B) were measured using scales and nineteen stereo images of them with walking postures were captured under outdoor illumination. In this study, the camera calibration and inverse perspective transformation technique was established fer the stereo vision system. Two calibration results were presented for farm A and fm B, respectively because setup distances from camera to cow were 510 cm at farm A and 630cm at farm B. Calibration error values fer the stereo vision system were within 2 cm for farm A and less than 4.9 cm for farm B. Eleven feature points of cow body were extracted on stereo images interactively and five assistant points were determined by computer program. 3D world coordinates for these 15 points were calculated by computer program and also used for calculation of cow body parameters such as withers height. pelvic arch height. body length. slope body length. chest depth and chest width. Measured errors for body parameters were less than 10% for most cows. For a few cow. measured errors for slope body length and chest width were more than 10% due to searching errors fer their feature points at inside-body positions. Equation for chest girth estimated by chest depth and chest width was presented. Maximum of estimated error fur chest girth was within 10% of real values and mean value of estimated error was 8.2cm. The analysis of cow body parameters using stereo vision system were successful although body shape on the binocular stereo image was distorted due to cow movements.

Development of Slender Aerodynamic Girder for Suspension Bridges (현수교 세장 내풍 단면의 개발)

  • Kwon, Soon-Duck;Lee, Myeong-Jae;Cho, Eukyung;Lee, Seung-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.241-256
    • /
    • 2010
  • This study intends to develop an aerodynamic girder for suspension bridge with width corresponding to 1/70 of the main span length. In the first step of present study, parametric study for the effects of major structural properties on aerodynamic stability of bridges was performed. The span length and natural frequency of bridges were found to be free from girder width, girder height, and aspect ratio of width to height. The empirical equation according to confidence interval was proposed to estimate the natural frequencies of bridges from span length. From the sensitivity analysis, it was revealed that the torsional frequency was dominant parameter among various structural properties that affected flutter velocity mostly. The final aerodynamic bridge section which satisfied the flutter criteria was found from section wind tunnel tests for 30 cross sectional models. The aerodynamic stability of the developed cross section was verified by multimode flutter analysis. The present economical cross section can be used for long span suspension bridge.

비전도성 에폭시를 사용한 RF-MEMS 소자의 웨이퍼 레벨 밀봉 실장 특성

  • 박윤권;이덕중;박흥우;송인상;박정호;김철주;주병권
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.129-133
    • /
    • 2001
  • In this paper, hermetic sealing was studied fur wafer level packaging of the MEMS devices. With the flip-chip bonding method, this B-stage epoxy sealing will be profit to MEMS device sealing and further more RF-MEMS device sealing. B-stage epoxy can be cured 2-step and hermetic sealing can be obtained. After defining $500{\mu}{\textrm}{m}$-width seal-lines on the glass cap substrate by screen printing, it was pre-baked at $90^{\circ}C$ for about 30 minutes. It was then aligned and bonded with device substrate followed by post-baked at $175^{\circ}C$ for about 30 minutes. By using this 2-step baking characteristic, the width and the height of the seal-line were maintained during the sealing process. The height of the seal-line was controlled within $\pm0.6${\mu}{\textrm}{m}$ and the strength was measured to about 20MPa by pull test. The leak rate of the epoxy was about $10^7$ cc/sec from the leak test.

  • PDF

Explicit Analysis of Flows in Box Culvert (사각형 암거흐름의 양해적 해석)

  • Yoo, Dong-Hoon;Uhm, Ho-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.481-494
    • /
    • 2003
  • Flow through the culvert is very complex depending on the characteristics of hydraulic conditions. A design method using a monograph is normally employed due to the wide range of flow characteristics and the difficulty of calculating inlet water depth. The present study suggests the method for determining the inlet water depth of box culvert using Bernoulli's equation. By employing the explicit equation of inlet water depth, a standard design method of box culvert is developed for a wide range of flow characteristics. Explicit solution techniques are proposed to determine the width and height, slope and discharge of box culvert.

Laminar Natural Convection Heat Transfer from an Isothermal Rectangular Beam Attached to Horizontal and Vertical Adiabatic Plates (수직 및 수평 단열판에 부착된 등온 사각비임에서의 자연대류 열전달)

  • 박재림;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.95-103
    • /
    • 1992
  • Laminar natural convection heat transfer from an isothermal rectangular beam attached to horizontal and vertical adiabatic plates has been studied for various aspect ratios of the beam and Grashof numbers. The local Nusselt number was increased with decreasing H/B for the constant beam width, B, and with increasing H/B for the constant beam height, H. The total mean Nusselt number of the vertical type was higher than that of horizontal type in the range of H/B.leq.0.52, but reversed in the H/B>0.52 at constant beam width. The total mean Nusselt number of the horizontal type was generally higher than that of vertical type at constant beam height. The total mean Nusselt number of the vertical type was higher than that of horizontal type in the range of H/B.leq.0.43 at constant wetted perimeter, but reversed in the H/B$\leq$0.43.

Comparison of Image reformation Using Personal Computer with Dentascan Program (CT scan의 다평면 재구성을 하는 Dentascan 프로그램과 개인용 컴퓨터를 이용한 영상재형성과의 비교에 관한 연구)

  • KIM Eun Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.7-16
    • /
    • 1997
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 5 mandibles of 5 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. Personal computer used for image reformation was PowerWave 6041120 (Power Computing Co, U.S.A.) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and Import ACCESS V1.H Designed Access Co., U.S.A.) for importing CT images and NIH Image 1.58 (NIH, U.S.A.) for image processing. Seven images were selected among the serial reconstructed cross-sectional images produced by Dentascan(DS group). Seven resliced cross-sectional images at the same position were obtained at the personal computer(PC group). Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformed cross-sectional images using Mac-compatible computer were highly correlated with those using workstation with Dentascan software(height : r²=0.999, p<0.001, width : r²=0.991, p<0.001). So, it is considered that we can use a personal computer with inexpensive softwares for the dental implant planning, instead of the expensive software and workstation.

  • PDF

Analysis of Flow in a Microchannel Branch by Using Micro-PIV Method (마이크로 PIV를 이용한 마이크로 분지관에서의 유동해석)

  • Yoon, Sang-Youl;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1015-1021
    • /
    • 2004
  • Micro-resolution Particle Image Velocimetry(Micro-PIV) was used to measure the flow in a micro-branch(Micro-Bypass). In this paper, effects of particle lump at the tip of a Micro-branch and difficulties of Micro-PIV measurements for microfluidics with branch passage were described. Micro-bypass was composed of a straight channel(200(100)${\mu}$m width ${\times}$ 80${\mu}$m height) and two branches which has 100(50)${\mu}$m width ${\times}$ 80${\mu}$m height. One of branches was straight and the other was curved. Experiments were performed at three regions along streamwise direction(entrance, middle and exit of branch) and five planes along vertical direction (0, ${\pm}$10, ${\pm}$20 ${\mu}$m) for the range of Re=0.24, 1.2, 2.4. Numerical simulation was done to compare with the measurements and understand the effects of particle lump at the tip of branch. And another fluid(3% poly vinyl Alcohol aqueous solution) were adapted for this study, so there were no particle sticking. In this case, we could get velocity difference between straight and curved branches.

Experiments of Wave Heights in front of a Perforated Wall under Obliquely Incident Waves:Monochromatic Wave Conditions (경사입사파 조건에서 유공벽 전면의 파고분포에 대한 실험:규칙파 조건)

  • Lee, Jong In;Kim, Young Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5B
    • /
    • pp.301-312
    • /
    • 2012
  • This study investigates the wave height distributions in front of a perforated wall generated by obliquely incident monochromatic waves through laboratory experiments conducted in a wave basin. Attention is paid to the difference or similarity between a plain wall and a perforated wall. And the investigation is focused on the chamber width and side wall effects of a perforated wall on the propagation characteristics of waves. The main results of this study show that the normalized wave height along a perforated wall is a significant difference compare to a plain wall cases. The side wall in the chamber suppresses the growth of the stem waves.