• Title/Summary/Keyword: Width Measurement

Search Result 1,028, Processing Time 0.025 seconds

Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator (IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구)

  • Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Quantity Measurement by CAFFE Model and Distance and Width Measurement by Stereo Vision (CAFFE 모델을 이용한 수량 측정 및 스테레오 비전을 이용한 거리 및 너비측정)

  • Kim, Won-Seob;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.679-684
    • /
    • 2019
  • We propose a method to measure the number of specific species of class using CAFFE model and a method to measure length and width of object using stereo vision. To obtain the width of an object, the location coordinates of objects appearing on the left and right sensor is compared and the distance from the sensor to the object is obtained. Then the length of the object in the image by using the distance and the approximate value of the actual length of the object is calculated.

An Efficient Pulse Width Measurement Method using Multiphase Clock Signals for Capacitive Touch Switches

  • Seong, Kwang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.773-779
    • /
    • 2013
  • We propose an efficient method to measure a pulse width using multiphase clock signals generated from a ring oscillator. These clocks, which have the same frequency and are evenly spaced, give multiple rising edges within a clock cycle. Thus, it is possible to measure a pulse width more accurately than with existing single clock-based methods. The proposed method is applied to a capacitive touch switch. Experimental results show that the capacitive touch switch with the proposed method gives a 118 fF resolution, which is 6.4 times higher than that of the touch switch with a single clock-based pulse width measurement method.

Development of Line Standards Measurement System Using an Optical Microscope (광학 현미경을 이용한 선표준물 측정 시스템 개발)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.72-78
    • /
    • 2009
  • We developed a line standards measurement system using an optical microscope and measured two kinds of line standards. It consists of three main parts: an optical microscope module including a CCD camera, a stage system with a linear encoder, and a measurement program for a microscopic image processing. The magnification of microscope part was calibrated using one-dimensional gratings and the angular motion of stage was measured to estimate the Abbe error. The threshold level in line width measurement was determined by comparing with certified values of a line width reference specimen, and its validity was proved through the measurement of another line width specimen. The expanded uncertainty (k=2) was about 100 nm in the measurements of $1{\mu}m{\sim}10{\mu}m$ line width. In the comparison results of line spacing measurement, two kinds of values were coincide within the expanded uncertainty, which were obtained by the one-dimensional measuring machine in KRISS and the line standards measurement system. The expanded uncertainty (k=2) in the line spacing measurement was estimated as $\sqrt{(0.098{\mu}m)^2+(1.8{\times}10^{-4}{\times}L)^2}$. Therefore, it will be applied effectively to the calibration of line standards, such as line width and line spacing, with the expanded uncertainty of several hundreds nanometer.

CFWC Scheme for Width Control using CCD Measurement System and Fuzzy PID Controller in Hot Strip Mills (CCD 폭 측정 시스템 및 퍼지 PID를 이용한 CFWC 제어기 설계)

  • Park, Cheol Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.991-997
    • /
    • 2013
  • In this paper, we propose a CFWC (CCD and fuzzy PID based width control) scheme to obtain the desired delivery width margin of a vertical rolling mill in hot strip process. A WMS(width measurement system) is composed of two line scan cameras, an edge detection algorithm, a glitch filter, and so on. A dynamic model of the mill is derived from a gauge meter equation in order to design the fuzzy PID controller. The controller is a self-learning structure to select the PID gains from the error and error rate of the width margin. The effectiveness of the proposed CFWC is verified from simulation results under a width disturbance of the entry in the mill. Using a field test, we show that the performance of the width control is improved by the proposed control scheme.

Analysis on the Measurement and Shape Classification of the Bead of Korean Male Children for the Headwear Sizing System (초등학교 남자아동의 모자 제작을 위한 머리부위 측정 및 형태 분석)

  • Kim Son Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.5 s.142
    • /
    • pp.737-744
    • /
    • 2005
  • This study was aimed to provide the measurement data and shape classification of the head of the Korean male children for the headwear sizing systems. Five hundred twenty male children, aged nine to twelve years, participated f3r this study. The 17 regions on the head and height, weight of the subjects were directly measured by the expert experimenters. Factor analysis, cluster analysis, GLM analysis and Tukey HSD test were performed using these data. Through factor analysis, low factors were extracted upon factor scores and those factors comprised $69.76\%$ for the total variances. Three clusters as their head shape were categorized using four factor scores by cluster analysis. Type 1 was characterized by the widest width and Bitragion arc, shortest head length. Type 2 had the longest head length and the widest side width and the highest head length and head circumference. Type 3 was characterized by the smallest head circumstance, head width and side width, and medium head length.

Real-time measurement of the width of piston ring groove on the grinding process (연삭가공 중인 피스톤 링 그루브의 실시간 연삭폭 측정법 개발)

  • Kim, Byoung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • A non-contact type measurement system is specially devised to measure the width of a piston ring groove in the grinding process. This system comprises a line camera with an imaging lens, collimated white light source, and a one axis translation stage. When the measurement system movesalong the diagonal direction of the cylinder, the line camera captures an image. By analyzing such images, the width of the piston ring groove can be determined. The experimental results prove that the proposed system is useful, especially as a monitoring system in grinding piston ring grooves on cylinders with accuracy of several micrometers in an area of dozens of millimeters.

Application of slab and plate width measurement using laser distance meter (Laser를 이용한 후물 판재류 및 Slap폭 측정 적용)

  • 최철호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1076-1078
    • /
    • 1996
  • According to ascending needs for quality assurance of plate by customer and automated measurement of dimension for slab, in plate mill, project is on preceeding to install measuring system to measure width, length and camber of slab and plate using laser distance meter. In this document, I will describe not technical point of view but idea of design for installation system.

  • PDF

Automatic measurement of blade width using image processing techniques (영상처리에 의한 연삭면 너비 계측)

  • 김선일;박종구;박찬웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.799-804
    • /
    • 1990
  • In the blade grinding process, Blade image is captured. It is captured in the environment with vibration, using monochrome CCD camera with high speed electronic shutter. The image is preprocessed using LoG filter and zero crossing. We used Hough transformation to detect straight lines from the preprocessed image. From the equations of detected lines, we calculated width between lines caused by grinders. This paper proposes automatic measurement of blade width to automate the process control of blade grinding line.

  • PDF

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF