• 제목/요약/키워드: Wide laser beam

검색결과 67건 처리시간 0.026초

연속파형 Nd:YAG 레이저를 이용한 SCM4강의 표면경화에 관한 연구 (A Study on the Surface Hardening of SCM4 Steel Using a Continuous Wave Nd:YAG Laser)

  • 나기대;신병헌;신호준;유영태
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.24-32
    • /
    • 2007
  • Laser surface hardening is beneficially used for surface treatment of structural steel. Due to very rapid heating and cooling rates, structural low-alloy steel(SCM4) can be hardened as self quenching. The aim of this research project is to improve the influence of the process laser parameters: laser power, spot size, surface roughness, and traverse speed. The laser beam is allowed to scan on the surface of the workpiece at the constant power(1095W), varying the traverse speed at 0.3m/min, 0.5m/min and 0.8m/min. The optical lens with the elliptical profile is designed to obtain a wide surface hardening area with uniform hardness. From the results of the experiment, it has been shown that the stable hardness is about 600$\sim$700Hv, when the laser power, focal position and the traverse speed are P=1095W, z=0mm and v=0.3m/min.

유체소자 성능향상을 위한 Polymethyl methacrylate(PMMA)의 레이저 표면처리 (Surface Modification of Polymethyl methacrylate(PMMA) by Laser Surface Treatment for Microfluidic Chip)

  • 신성권;이상돈;이천
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.334-337
    • /
    • 2007
  • After the advent of micro-Total Analysis Systems(${\mu}-TAS$) based on silicon various polymer for microfluidic chip has been studied. Polymer materials for microfluidic compared with silicon and glass which were traditional materials of a microfluidic chip, have the advantages of economical efficiency simple manufacturing process and wide materials selectivity corresponding to fluids. Surface energy of polymers we, however lower than silicon or glass. To overcome this problem, various surface modification methods have been investigated. The surface modification using laser has the advantage of the simple experiment that only directly irradiated laser beam on the material surface in the air. This work discuss the surface modification of polymethly methacrylate(PMMA) by 4th harmonic Nd:YAG laser (${\lambda}266nm$, pulse) treatment. After the laser treatment, the PMMA surface was investigated using a contact angle measuring instrument. The contact angle was decreased with a increase of the surface oxygen content. This result means the surface energy of PMMA was increased by the laser treatment without changing of its bulk characteristics.

우주전파관측용 음향광학 전파분광기의 제작 (Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations)

  • 임인성;최재현;오승엽
    • 한국전자파학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1997
  • 우주전파신호 분석을 위한 음향광학 전파분광기를 제작하였다 이 시스템은 우주로부터 수신된 미약한 전파신 호를 분석하는 신호처리 장치로 레이저 공진기 광학계. 광편향소자와 CCD로 구성된다. 이 시스템은 전파 시호를 분석하는 기존의 필터뱅크, 자기상관 분광기와는 달리 레이저와 광학계를 사용하여 빔을 유도하고 전파신호를 광편향소자에 의해 초음파로 변환하여 레이저빔을 회절시키는 새로운 방식의 전파 분광기이다. 광원으로는 He-Ne 레이저를 사용하였으며, 1 GHz에서 2 GHz까지의 대역폭을 갖는 광대역 GaP 광편향소자를 사용였다 . 또한 광신호 검출을 위해 2,048 채널의 CCD를 제작하였다 본 연구에서는 음향광학효과에 대한 이론적 배을 설명하고 레이저 공진기를 이용한 광학계의 설계, 광학마운트의 제작, CCD Driver, 인터페이스 제작과 이를 이용한 전파 신호의 측정에 대해 논의하였다. 전파선호의 측정결과 0차광이 1차광을 간섭시켜 2,048채널 중 I,000채널의 대역폭을 갖는 분팡가 성능을 갖게 되었다.

  • PDF

KDP결정을 이용한 고강도 Nd 레이저광의 제4 고조파변환 해석 (Analysis of Fourth Harmonic Conversion of High Intensity Nd Laser Beam in KDP Crystal)

  • 장용무;김병태;강형부
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.541-550
    • /
    • 1992
  • The fourth harmonic conversion(FHC) efficiency of high-power Nd laser pulse with wavelength of 1.054x10S0-6Tm using two KDP crystals(doubler adn quadrupler) was simulated numerically. Simulation results show that for the perfect phase-matching condition the FHC efficiency were 60-70% for several hundreds MW/cmS02T class and over 70% for GW/cmS02T class laser pulses. And the overall characteristics of FHC were discussed in terms of effects of input intensity, crystal length, and mismatch angle Δ$\theta$. Optimum method to FHC was type-II doubler & type-I quadrupler KDP crystal because type-II KDP doubler crystal has wide tolerance of acceptance matching-angle.

초점렌즈 F-수 변화에 의한 냉간금형강 STD11 의 연속파 Nd:YAG 레이저 표면경화 특성 (Characteristics on Surface Hardening by using of Continuous Wave Nd:YAG Laser of Cold-Work Die Steel(STD11) about Variation of Focal Lens F-number)

  • 황찬연;양윤석;이가람;유영태
    • 한국정밀공학회지
    • /
    • 제29권4호
    • /
    • pp.395-408
    • /
    • 2012
  • An experimental investigation with 2.8kW Nd:YAG laser system was carried out to study the effects of different laser process parameters on the microstructure and hardness of STD11. The optical lens with the elliptical profile are designed to obtain a wide surface hardening area with uniform hardness. The Laser beam is allowed to scan on the surface of the work piece varying the power (1600, 1800 and 1900kW) and traverse speed (200, 400, 600, 800 and 1000mm/min) at three different F-numbers of lens. After laser surface treatment three zones, In the microstructure have been observed : melted zone(decarburization), heat affected zone(martensite), and the substrate.

Spectral Characteristics of 50 GHz FSR Etalon for Wide-band DWDM Application

  • Kim, Jong-Deog;Moon, Jong-Tae
    • Journal of the Optical Society of Korea
    • /
    • 제8권3호
    • /
    • pp.104-107
    • /
    • 2004
  • The periodic transmission spectrum of a solid etalon for wide-band capability is analyzed both theoretically and experimentally. In the transmission spectrum with an incident area of a photodetector, the peak wavelength and transmittance are deeply dependent on the incident angle and the divergence angle of the input laser beam. A thermal adjustment for a solid etalon is an optional way to control the transmission spectrum instead of the inefficient fine-angle alignment. In the result, we present the deviations of free spectral range (FSR) by the change in angle and temperature over wide wavelength range.

Ar 이온빔 식각과 전자선리소그래피 방벙으로 제작한 고온초전도 조셉슨 접합 (Fabrication of High-T$_c$ Superconducting Josephson Junctions by Ar lon Milling and E-Beam Lithography)

  • 이문철;김인선;이정오;유경화;박용기;박종철
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.91-94
    • /
    • 1999
  • A new type of high-T$_c$ superconducting Josephson junctions has been prepared by Ar ion beam etching and electron beam lithography. YBa$_2Cu_3O_{7-x}$ (YBCO) films deposited on (001) SrTiO$_3$ single crystal substrate by pulsed laser deposition were patterned by Ar ion milling with photolithography. The narrow slit with a electroresist mask, about 1000 ${\AA}$ wide, was constructed over a 3 ${\sim}$ 5 ${\mu}$m bridge of a 1200-${\AA}$-thick YBCO film by electron beam lithography. The slit was then etched by the Ar ion beam to form a damaged 600-${\AA}$-thick YBCO. Thus prepared structure forms an S-N-S (YBCO - damaged YBCO - YBCO) type Josephson junctions. Those junctions exhibit RSI-like I-V characteristics at 77 K. The properties of the Josephson junctions such as I$_c$ R$_N$, and J$_c$ were characterized.

  • PDF

적응적 에러 보정과 다이나믹 안정기를 이용한 레이저 유도 초음파 검사 시스템 개발 (Development of a Laser-Generated Ultrasonic Inspection System by Using Adaptive Error Correction and Dynamic Stabilizer)

  • 박승규;백성훈;박문철;임창환;나성웅
    • 비파괴검사학회지
    • /
    • 제25권5호
    • /
    • pp.391-399
    • /
    • 2005
  • 레이저 유도 초음파 시스템은 놀은 공간분해능으로 스캐닝 하면서 광대역 범위에서 검사를 할 수 있는 비접촉식 검사 장치이다. 유도되는 초음파 신호의 크기는 펄스레이저의 출력에 의해서도 변화하지만, 연속발진 레이저빔이 위치하는 표면 상태에 따라서도 측정되는 초음파 세기는 크게 변화한다. 본 논문에서는 안정된 레이저 유도 초음파 시스템을 구성하기 위하여 펄스 레이저빔의 출력을 측정하여 초음파 발생 오차를 보정하였으며, 대상체 표면의 상태에 따라 크게 변화하는 측정용 레이저 간섭계의 측정 이득 변화를 매순간 측정하여 측정 오차를 보정하였다. 본 논문에서는 대상체 표면을 스캐닝 할 수 있도록 다이나믹 안정기가 부착된 레이저 유도 초음파 시스템을 개발하였다. 개발한 레이저 초음파 시스템은 스캐닝 과정에서 간섭계의 이득이 최대가 되는 순간을 적응적으로 포착하여 초음파를 발생시키고, 유도된 초음파 신호를 고속으로 샘플링 한 후에 실시간으로 신호처리를 한다. 본 논문에서는 안정적인 레이저 유도 초음파 시스템을 구성하기 위한 전체 시스템의 하드웨어 구성 방법과 제어 알고리듬에 대하여 기술한다. 또한 본 논문에서 제안한 발생오차 보정방법과 측정오차 보정 방법이 시스템의 성능 향상에 유효함을 실험을 통하여 확인하였다.

임의형상가공시스템의 정속위치제어 (A Study on Constant-Speed Position Control of Solid Freeform Fabrication System)

  • 정용래;고민국;김승우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.75-78
    • /
    • 2002
  • SFFS(Solid Freeform Fabrication System) is commercializing to rapid prototyping concept in world-wide some corporations including the States, have much technological problems yet and need new mode for agile solid freeform fabrication as well as prototyping. In this paper, we design an automatic control algorithm that the cutting path of laser beam, on the SFFS, is controlled with constant speed. The designed algorithm for constant-speed path control is implemented and experimented in the $CAFL^{VM}$ (Computer Aided Fabrication of Lamination for Various Material) system, the new SFFS which is developed in this paper. Its process is an automated fabrication method in which a 3D object is constructed from STL(SToreoLithography) 2D data, derived from CAD 3D image, by sequentially laminating the part cross-sections. The constant-speed path control is started from the STL data. After STL file is modified in data format to be available for control. The fabrication of the 2D part is, with constant speed, conducted from the 23 position data by laser beam. we confirm its high-performance through experiment results from the application into $CAFL^{VM}$ system.

  • PDF

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF