• Title/Summary/Keyword: Wide angle

Search Result 1,037, Processing Time 0.024 seconds

Comparison of old-old aged women's pants basic pattern using 3D data (3차원 계측데이터를 활용한 고령 여성의 팬츠 원형 비교)

  • Cha, Su-Joung
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.3
    • /
    • pp.360-376
    • /
    • 2018
  • The purpose of this study was to make a pants pattern suitable for women 70 to 85 years of age, then analyze that- pattern's shape, size, appearance, fit, allowance and air gap. Participants made the pattern using 3D simulation program DC Suite version 5.1. The results suggest a design method suitable for the lower-body shapes of elderly women. In external appearance, the A-type earned the highest evaluation in all items except the allowance of the back waist and back hip. The L type earned the highest evaluation in the allowance of back waist and hips. The A-type's, back waist appeared set at an angle that did not match the body shape of an old-old aged woman in the center-back-line setting. Therefore, the pattern method of A-type combined with L-type's method of center back, produces an excellent pants pattern. Evaluation of the air gaps among patterns revealed that; the A-type showed the largest air gap in waist and hip circumference and the smallest air gap in thigh circumference. The waists, abdomen, and hip circumferences of older women often become larger while their legs become slimmer. This study accounted for those factors in determining a pattern suitable for the lower-body shape of old-old aged women. However, participants only analyzed four patterns and compared them with women 70 to 85, years of age. Therefore, it is necessary to develop industrial patterns applicable to a wide age group.

The Biomechanical Evaluation of New Walking-shoes (신 워킹 전문화의 생체역학적 기능성 평가)

  • Kim, Eui-Hwan;Chung, Chae-Wook;Lim, Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.193-205
    • /
    • 2006
  • This study was to analysis the kinematic and kinetic differences between new walking shoe(NWS : RYN) and general walking shoe(GWS). The subjects for this study were 10 male adults who had the walking pattern of rearfoot shrike with normal foot. The movement of one lower leg was measured using plantar pressure and Vicon Motion Analysis Program(6 MX13 and 2 MX40 cameras : 100 f / s) while the subjects walked at the velocity(1.5m/s. on 2m).. The results of this study was as follows : 1. The NWS was better than the GWS that caused injuries such as adduction, abduction and pronation are reduced While walking on a perpendicular surface, the landing angle and the knees angles were extensive which makes walking more safe which reduces anxiety and uneasiness. 2. The bottom of the NWS were now made into a more circular arch which supports the weight of the body and reduces the irregular angles when wearing GWS. This arch made the supporting area more wide which made the upholding the trunk of the body more effective. The whole bottom of the foot that supports the weight is more flexible in addition, increases the safeness of walking patterns and the momentum of the body. 3. The moment the heel of the foot of the NWS touch the ground, the range of the pressure were partially notable and the range of the pressure on the upper part of the thigh were dispersed The injuries that occurred while walking. primary factors when a shock related injuries are reduced Judgements of the impacts of the knees and the spinal column dispersing could be made.

Characterization of the UV Oxidation of Raw Natural Rubber Thin Film Using Image and FT-IR Analysis

  • Kim, Ik-Sik;Lee, Bok-Won;Sohn, Kyung-Suk;Yoon, Joohoe;Lee, Jung-Hun
    • Elastomers and Composites
    • /
    • v.51 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Characterization of the UV oxidation for raw natural rubber (NR) was investigated in controlled conditions through image and FT-IR analysis. The UV oxidation was performed on a thin film of natural rubber coated on a KBr window at 254 nm and room temperature to exclude the thermal oxidation. Before or after exposure to UV light, image of the NR thin film was observed at a right or tilted angle. FT-IR absorption spectra were measured in transmission mode with the UV irradiation time. The UV oxidation of NR was examined by the changes of absorption peaks at 3425, 1717, 1084, 1477, 1377, and $833cm^{-1}$ which were assigned to hydroxyl group (-OH), carbonyl group (-C=O), carbon-oxygen bond (-C-O), methylene group $(-CH_2-)$, methyl group $(-CH_3)$, and cis-methine group $(cis-CCH_3=CH-)$, respectively. During the initial exposure period, the results indicated that the appearance of carbonyl group was directly related to the reduction of cis-methine group containing carbon-carbon double bond (-C=C-). Most of aldehydes or ketones from carbon-carbon double bonds were formed very fast by chain scission. A lot of long wide cracks with one orientation at regular intervals which resulted in consecutive chain scission were observed by image analysis. During all exposure periods, on the other hand, it was considered that the continuous increment of hydroxyl and carbonyl group was closely related to the decrement of methylene and methyl group in the allylic position. Therefore, two possible mechanisms for the UV oxidation of NR were suggested.

Locomotion of Dog-like Quadruped Robots: Walk and Trot (견형 4족 로봇의 위치 이동: 걷기 및 속보)

  • Lim, Seung-Chul;Kim, Kwang-Han
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.1
    • /
    • pp.51-59
    • /
    • 2011
  • This paper is concerned with locomotion of dog-like quadruped robots that can adapt to various terrains, mainly dealing with implementation methods and characteristics of static and dynamic gaits. To this end, a 12-DOF robot is built in house, motional trajectories of its body and feet are generated mimicking biological life, and the corresponding leg joint angles are analytically obtained by inverse kinematics. Such joint angle data are then applied to the robot's ADAMS model for computer simulations so that the planned walk and trot gaits are both confirmed dynamically stable. However, contrary to the simulation results, previous trot patterns showed unstable behavior during experiments. This problem led us to analyze the reason, and in the course we discovered the importance of maximally utilizing the concept of WSM rather than ZMP and therefore reducing the gait period to secure the stability of dynamic gaits such as trot.

A Study for Change of Audio Data according to Rotation Degree of VR Video (VR 영상의 회전각도에 따른 오디오 데이터 변화에 관한 연구)

  • Ko, Eun-Ji;Yang, Ji-Hee;Kim, Young-Ae;Park, Goo-Man;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1135-1142
    • /
    • 2017
  • In this paper, we propose an algorithm that can automatically mix the screen and sound by tracking the change of the sound data according to the screen change so that the real sound can be implemented in the personal broadcasting service. Since the personal broadcasting service is often broadcasted lively, it should be convenient to have a real-time mixing. Through experiments, it was confirmed that the sound pressure changes in a wide range in the high frequency band related to the clarity for understanding according to the rotation angle change of the screen. Regression analysis of the sound pressure changes at 2kHz, 4kHz, and 8kHz, The attenuation change of sound pressure was observed at the slope of -1.17, the slope of -2.0, and the slope of -2.44 for each frequency. Therefore, these experiment results can be applied to the VR service. This study is expected to be useful data in the implementation of personal broadcasting service.

Development of Three Dimensional Fracture Strain Surface in Average Stress Triaxiaility and Average Normalized Lode Parameter Domain for Arctic High Tensile Steel: Part I Theoretical Background and Experimental Studies (극한지용 고장력강의 평균 응력 삼축비 및 평균 정규 로드 파라메터를 고려한 3차원 파단 변형률 평면 개발: 제1부 이론적 배경과 실험적 연구)

  • Chong, Joonmo;Park, Sung-Ju;Kim, Younghun
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.445-453
    • /
    • 2015
  • The stress triaxiality and lode angle are known to be most dominant fracture parameters in ductile materials. This paper proposes a three-dimensional failure strain surface for a ductile steel, called a low-temperature high-tensile steel (EH36), using average stress triaxiality and average normalized lode parameter, along with briefly introducing their theoretical background. It is an extension of previous works by Choung et al. (2011; 2012; 2014a; 2014b) and Choung and Nam (2013), in which a two-dimensional failure strain locus was presented. A series of tests for specially designed specimens that were expected to fail in the shear mode, shear-tension mode, and compression mode was conducted to develop a three-dimensional fracture surface covering wide ranges for the two parameters. This paper discusses the test procedures for three different tests in detail. The tensile force versus stroke data are presented as the results of these tests and will be used for the verification of numerical simulations and fracture identifications in Part II.

Analysis and Application of the Reflection Characteristics of a Simple Retro-reflector (1차원적 단순배열구조 재귀반사체의 반사출력광 특성 및 응용)

  • Jeong, Yong-Beom;Hong, Sung-Hoon;Lee, Seung-Gol;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.239-244
    • /
    • 2014
  • Retro-reflectors have been used for a wide range of applications such as traffic safety, special blinds, optical devices, etc. We analyzed the characteristics of the reflected light of a strap retro-reflector as a function of incidence angle. It is expected that various solar control structures may be designed more quantitatively using the characteristic chart we have prepared.

A Study on the Velocity of the Mandibular Movement in Patients with Temporomandibular Disorders (측두하악장애환자에서 하악의 운동속도에 관한 연구)

  • Jung, Chan;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.167-181
    • /
    • 1997
  • The aim of this study was to investigate the relationship between velocity and factors which could affect the velocity of mandibular movement. For this study, 30 dental students without any masticatory signs and symptoms and 90 patients with temporomandibular disorders(TMD) were selected as the control group and the patients group, respectively. After determining Angle's classification and lateral guidance pattern of occlusion, clinical examination for TMD was perfomed. Velocity and distance of mandibular movements were recorded with BioEGN, reproducibility index of lateral excursions was evaluated by Pantronic(PRI) and BioEGN (BERI) activity in masticatory and cervical muscles were measured with BioEMG, and occlusal contact time and cross-arch unbalance(Total left-right statistics, TLR) on clenching were recorded with T-scan, respectively. The results of this study were as follows : 1. Velocity in the patients was faster than that in the controls in most mandibular movements, but on wide opening and closing movement, result was reverse. 2. Velocity on closing movements were faster than that on opening movements in the control group and a similar tendency was also shown in the patients group. 3. Patients with muscle disorders showed a tendency to have the highest value of velocity of all diagnostic subgroups, while patients with degenerative joint diseases showed a tendency to have the lowest value. 4. Patients with canine guidance showed a tendency to have the highest value of velocity in three subgroups by lateral guidance pattern, while patients with group function showed a tendency to have the lowest value. 5. BERI had a positive correlation with opening velocity on lateral excursion, while TLR had a negative correlation with opening velocity on swallowing. 6. EMG activity on clenching in masticatory muscles had negative correlation with opening velocity on border movements, and on swollowing, while the activity in rest correlated positively with opening velocity on border movements. 7. There were positive correlation between the velocity and the distance in long components of mandibular trajectory.

  • PDF

Using Contour Matching for Omnidirectional Camera Calibration (투영곡선의 자동정합을 이용한 전방향 카메라 보정)

  • Hwang, Yong-Ho;Hong, Hyun-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.125-132
    • /
    • 2008
  • Omnidirectional camera system with a wide view angle is widely used in surveillance and robotics areas. In general, most of previous studies on estimating a projection model and the extrinsic parameters from the omnidirectional images assume corresponding points previously established among views. This paper presents a novel omnidirectional camera calibration based on automatic contour matching. In the first place, we estimate the initial parameters including translation and rotations by using the epipolar constraint from the matched feature points. After choosing the interested points adjacent to more than two contours, we establish a precise correspondence among the connected contours by using the initial parameters and the active matching windows. The extrinsic parameters of the omnidirectional camera are estimated minimizing the angular errors of the epipolar plane of endpoints and the inverse projected 3D vectors. Experimental results on synthetic and real images demonstrate that the proposed algorithm obtains more precise camera parameters than the previous method.

Transmittance Improvement with Reversed Fishbone-Shape Electrode in Vertical Alignment Liquid Crystal Display

  • Lim, Young Jin;Kim, Hyo Joong;Kim, Min Su;Kim, Gi Heon;Kim, Yong Hae;Lee, Gi-Dong;Lee, Seung Hee
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.794-798
    • /
    • 2016
  • A polymer-stabilized vertical alignment (PS-VA) mode with fishbone-shaped pixel electrode structure is mainly used in large-sized liquid crystal displays (LCDs) owing to its advantages such as wide viewing angle, good transmittance and fast response time. One drawback of this mode is a main bone electrode, which crosses in the center of a pixel. It causes the transmittance to decrease badly because LCs cannot be reoriented in this region, and thus, it is particularly unfavorable in an ultra-high-definition LCD. Here, we propose an innovative structure with the main bone electrode relocated to the edge area in a pixel, and investigate how this reverse directed fishbone-shaped pixel electrode structure affects electro-optic characteristics. The proposed structure shows enhanced electro-optic performance, such as the higher transmittance and the faster response time than the conventional VA mode with fishbone-shaped pixel electrode structure.