• 제목/요약/키워드: Wide Monitor

검색결과 251건 처리시간 0.022초

PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어 (Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL))

  • 최성욱;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

From Exoscope into the Next Generation

  • Nishiyama, Kenichi
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권3호
    • /
    • pp.289-293
    • /
    • 2017
  • An exoscope, high-definition video telescope operating monitor system to perform microsurgery has recently been proposed an alternative to the operating microscope. It enables surgeons to complete the operation assistance by visualizing magnified images on a display. The strong points of exoscope are the wide field of view and deep focus. It minimized the need for repositioning and refocusing during the procedure. On the other hand, limitation of magnifying object was an emphasizing weak point. The procedures are performed under 2D motion images with a visual perception through dynamic cue and stereoscopically viewing corresponding to the motion parallax. Nevertheless, stereopsis is required to improve hand and eye coordination for high precision works. Consequently novel 3D high-definition operating scopes with various mechanical designs have been developed according to recent high-tech innovations in a digital surgical technology. It will set the stage for the next generation in digital image based neurosurgery.

Application of the Arrhenius Equation in Geotechnical Engineering

  • Yoon, Hyung-Koo
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.575-581
    • /
    • 2014
  • The reliable measurement of geotechnical properties in cold regions should account for their fluctuations with temperature. The objective of this paper is to introduce a chemical model based on the Arrhenius equation that can predict the properties of materials as their temperature changes. The model can monitor phases and reaction rates as they change with temperature. It has been already applied in the fields of geology, construction, chemistry, materials engineering, and food science. The application of the Arrhenius equation requires a reliable estimate of the activation energy. Therefore, this study also demonstrates several methods for evaluating activation energy in different contexts through summaries and reviews of previous research related to the Arrhenius equation. This paper may be of wide use in obtaining temperature-dependent parameters in geotechnical engineering.

Prevalence of Torque teno viruses among pigs and cattle in Korea

  • Kim, Ji Yeon;Kweon, Chang Hee;Lee, Kyung Woo;Jeong, Wooseog;Jean, Young Hwa
    • 대한수의학회지
    • /
    • 제50권1호
    • /
    • pp.55-57
    • /
    • 2010
  • Torque teno virus (TTV), a species of Anellovirus, is a non-enveloped single stranded DNA virus with a wide range of animal hosts. The incidence of TTV is quite ubiquitous throughout the world. A total of 235 serum samples obtained from 137 pigs and 98 cattle at slaughterhouses in Korea during April 2005 to May 2005 were tested by TTV-specific PCR as to monitor prevalence of TTV among swine and cattle. As a result, the prevalent rates of TTVs in pigs and cattle were 43.1% and 4.1%, respectively. It seems that TTV infection is quite prevalent in swine population.

실시간 의학 영상 처리에 관한 연구 (Study on the Real Time Medical Image Processing)

  • 유선국;이건기;백남필;김원기
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.117-117
    • /
    • 1987
  • The medical image processing system is intended for a diverse set of users in the medical Imaging Parts. This system consists of a 640 Kbyte IBM-PC/AT with 30 Mbyte hard disk, special purpose image processor with video input devices and display monitor. Image may be recorded and processed in real time at sampling rate up to 10 MHz. This system provides a wide range of image enhancement processing facilities via a menu-driven software packages. These facilities include point by point processing, image averaging, convolution filter and subtraction.

Improvement of IPS Mode Structure using Fast Q-tensor Method

  • Choi, Hyun-Chul;Lee, Joun-Ho;Choi, Seong-Wook;Yang, Jin-Seok;Lee, Gi-Dong
    • Journal of Information Display
    • /
    • 제8권2호
    • /
    • pp.1-4
    • /
    • 2007
  • IPS and VA have evolved in various structures such as H-IPS, AS-IPS, and S-PVA gain more competitiveness. The new pixel structures inherently have more domains which cause disclination areas. The effect of disclination is no longer neglected in those structures. A new simulation tool based on FAST Q-tensor method enables one to predict the shape of disclinations and the resulting optical properties. It ensures more accurate results compared to vector-based simulation. We applied this simulation tool for the development of 26-inch wide monitor having H-IPS mode.

산화물 세라믹 재료 기반 자외선 센서 (Ultra Violet (UV) Sensor based on Oxide Ceramic Materials)

  • 류학기
    • 세라미스트
    • /
    • 제22권1호
    • /
    • pp.27-35
    • /
    • 2019
  • Research on ultraviolet (UV) light detection has attracted considerable attention from scientific researchers in related fields. It can be said that it is a very important time to accurately monitor the UV irradiation amount according to the wavelength region in real time. The oxide is very diverse in its kind and has the advantage of being able to efficiently control the band gap through band gap engineering. In addition, it is very stable in response to heat and atmospheric oxygen when UV is absorbed. Also, there is a known method that can effectively manufacture oxide nanoparticles and nanorods through various synthesis methods, and researches for improving the sensitivity of UV sensors have been carried out using this method. In this paper, we introduce the materials that can be used as UV sensors among various wide band oxide materials, and review the results of researches of various UV sensors using nano materials.

다기능 DO 센서용 계측시스템 개발 (Development of the Measurement System for the Multi-Functional DO Sensor)

  • 이동희;김태진;최복길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.86-88
    • /
    • 1996
  • A method is presented for the development of the PC-based measurement system on the 6 cathodes-single anode type multi-functional oxygen electrodes for detecting various components of the solution by measuring the dissolved oxygen(DO) concentration. The system is consisted with the 6 channel sensor signal modyfing circuits for the sensor and the PC interface circuits using the single chip microprocessor 80c196kc. Typical polarograms for the DO probes under test using this sensor circuits are presented. This system covers wide range of measuring time from 300sec to over 16 hour in one measurement step by programming the 9 monitor disply mode.

  • PDF

Damage Detection in Fiber Reinforced Composites Containing Electrically Conductive Phases

  • Shin, Soon-Gi;Hideaki Matsubara
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.201-205
    • /
    • 2000
  • Fiber reinforced plastic (FRP) composites and ceramic matrix composites (CMC) which contain electrically conductive phases have been designed and fabricated to introduce the detection capability of damage/fracture detection into these materials. The composites were made electrically conductive by adding carbon and TiN particles into FRP and CMC, respectively. The resistance of the conductive FRP containing carbon particles showed almost linear response to strain and high sensitivity over a wide range of strains. After each load-unload cycle the FRP retained a residual resistance, which increased with applied maximum stress or strain. The FRP with carbon particles embedded in cement (mortar) specimens enabled micro-crack formation and propagation in the mortar to be detected in situ. The CMC materials exhibited not only sensitive response to the applied strain but also an increase in resistance with increasing number of load-unload cycles during cyclic load testing. These results show that it is possible to use these composites to detect and/or fracture in structural materials, which are required to monitor the healthiness or safety in industrial applications and public constructions.

  • PDF

HOW TO MONITOR AGN INTRA-DAY VARIABILITY AT 230 GHZ

  • 김재영
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.44.2-44.2
    • /
    • 2013
  • We probe the feasibility of high-frequency radio observations of very rapid flux variations in compact active galactic nuclei (AGN). Our study assumes observations at 230 GHz with a small 6-meter class observatory, using the SNU Radio Astronomical Observatory (SRAO) as example. We find that 33 radio-bright sources are observable with signal-to-noise ratios larger than ten. We derive statistical detection limits via exhaustive Monte Carlo simulations assuming (a) periodic, and (b) episodic flaring flux variations on time-scales as small as tens of minutes. We conclude that a wide range of flux variations is observable. This makes high-frequency radio observations - even with small observatories - a powerful probe of AGN intra-day variability; especially, those observations complement observations at lower radio frequencies with larger observatories like the Korean VLBI Network (KVN).

  • PDF