• 제목/요약/키워드: Whole spine lateral radiography

검색결과 3건 처리시간 0.022초

척추 전장 측면 방사선검사 시 손바닥 정면 자세가 척추골반지표에 미치는 영향 (Effect of Palm Facing Forward Posture on SpinoPelvic Parameters on the Whole Spine Lateral Radiography)

  • 주영철;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.391-396
    • /
    • 2022
  • The purpose of this study was to investigate the effect of cross arms and palms facing forward on spinopelvic parameters during the whole spine lateral radiography. In addition, we would like to present the usefulness of a posture with the palm facing forward during whole spine lateral radiography of the spine using EOS. The subjects of this study were images of a total of 50 patients (18 males, 32 females) who whole spine lateral radiography using the conventional method and the EOS method from October 2020 to March 2021. The posture used in this study was set as 'CAP' for cross arms and 'PUSH' for posture with palms facing forward. In this study, among the spinal stability factors, thoracic kyphosis (thoracic vertebrae 4 to 12), lumbar lordosis (lumbar vertebrae 1 to sacrum 1), sagittal vertical axis, sacral slope, and shoulder flexion angle were compared on average. The mean thoracic kyphosis was 34.52±12.46° for CAP and 28.46±10.81° for PUSH (p<0.01). The lumbar lordosis of CAP was 42.45±17.45°and that of PUSH was 40.56±16.14°(p>0.57). The sagittal vertical axis was 26.59±34.34 mm in CAP and 21.21±35.41 mm in PUSH (p>0.44). In CAP, the sacral slope was 30.96±10.29°, and in PUSH, it was 31.01±10.19° (p>0.98). shoulder flexion angle was 38.31±8.24° for CAP and 26,08±6.71° for PUSH(p<0.01). As a result of this study, the PUSH posture is considered to be a posture that can minimize the shoulder flexion angle and can perform a stable examination while minimizing changes in spino-pelvic parameter.

노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가 (Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination)

  • 박혜민;윤용수;김정수;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

목과 어깨근육 운동프로그램이 전방머리자세의 척추-골반 정렬 변화에 미치는 영향 (Effects of Neck and Shoulder Exercise Program on Spino-Pelvic Alignment in Subject with Forward Head Posture)

  • 강효정;양회송
    • 대한통합의학회지
    • /
    • 제7권4호
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose : Excessive computer use frequently results in musculoskeletal disorders of the neck and shoulder such as forward head posture (FHP). The purpose of this study was to investigate effects of neck and shoulder exercise program on spino-pelvic alignment and the correlation between change in head and neck posture and spino-pelvic alignment in FHP. Methods : The study included 44 participants with FHP. The participants performed the exercise for correction of FHP 2-3 times a week for 4 weeks. We examined whole spine X-ray images in the lateral standing position with both arms crossed. We measured anterior head translation distance (AHT), craniovertebral angle (CVA), cervical lordosis (CL), thoracic kyphosis (TK), lumbosacral lordosis (LSL), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI) of the subjects. The association between change in AHT and each spino-pelvic parameter was also subjected to Pearson's correlation coefficient analysis. Results : There were statistically significant differences before and after exercise in the parameters of AHT, CVA, and SS (p<.05). Significant negative correlation was observed between the change in AHT and CVA (r=-.768, p<.001), and CL (r=-.388, p<.05). There was significant positive correlation between the change in AHT and SS (r=.328, p<.05), and PI (r=.333, p<.05). However, no significant correlation was observed in change in AHT with that of TK, LSL, and PT. Conclusion : Based on the above results, we conclude that there is a relationship between change in AHT, which is a parameter associated with forward displacement of the head, and that of CVA, CL, SS, and PI after exercise in cases of FHP.