• Title/Summary/Keyword: Whole body scan

검색결과 179건 처리시간 0.023초

골다공증성 척추체 압박골절에 대한 경피적 척추성형술시 자기공명영상과 골 주사 검사의 의의 (The Value of Preoperative MRI and Bone Scan in Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures)

  • 김세혁;이완수;서의교;신용삼;장호열;전평
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권7호
    • /
    • pp.907-915
    • /
    • 2001
  • Objective : Percutaneous vertebroplasty is often complicated by the presence of multiple fractures or non-localizing pain in the patients with osteoporotic vertebral fractures. The purpose of this study is to estimate the value of preoperative radiologic studies in the localization of symptomatic vertebrae and to determine the factors which can influence on the clinical results. Materials and Methods : We retrospectively reviewed the clinical and radiologic data of 57 vertebrae in 30 patients underwent percutaneous vertebroplasty for osteoporotic vertebral compression fractures. Inclusion criteria was severe pain(McGill-Melzack score 3, 4 or 5) associated with the acute vertebral fractures and absence of spinal nerve root or cord compression sign. Acute symptomatic vertebral fracture was determined by the presence of signal change on MR images or increased uptake on whole body bone scan. Results : Pain improvement was obtained immediately in all patients and favorable result was sustained in 26 patients(86.7%) during the mean follow-up duration of 4.7 months(5 complete pain relief, 21 marked pain relief). Those who underwent vertebroplasty for all acute symptomatic vertebrae had significantly better clinical result than those who did not. Further vertebral collapse and eventual bursting fracture occurred in 1 vertebra which showed intradiskal leakage of bone cement and disruption of cortical endplate on postoperative CT scan. Conclusion : Preoperative MR imaging and whole body bone scan are very useful in determining the symptomatic vertebrae, especially in the patients with multiple osteoporotic vertebral fractures. To obtain favorable clinical result, the careful radiologic evaluation as well as clinical assessment is required. Control of PMMA volume seems to be the most critical point for avoiding complications.

  • PDF

전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가 (The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan)

  • 김동석;유희재;류재광;유재숙
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.67-72
    • /
    • 2010
  • 본원에서는 비심장 수술환자의 수술 전후 심장사건의 위험도 평가를 위해 심근관류 SPECT를 시행하고 있다. 암환자의 경우 수술 전에 전신 뼈 검사 혹은 전신 PET 검사로 암 전이 여부 확인 후 심근관류 SPECT를 시행하여 불필요한 검사 처방을 막고 있다. 하지만 단기 병동 입원 환자의 경우 재원 일수를 줄이고자 전신 뼈 검사 후 최소 16시간의 간격을 두고 $^{201}Tl$ 심근관류 SPECT를 시행하는 경우가 있지만 아직까지 서로 다른 동위원소 투여로 인한 crosstalk contamination의 영향에 대한 평가가 제대로 이루어지지 않은 실정이다. 따라서 본 연구에서는 anthropomorphic torso phantom을 이용한 실험과 실제 환자 데이터를 이용하여 이에 대한 유효성 검정을 시행하고자 한다. 2009년 8월부터 9월까지 서울아산병원 핵의학과에서 $^{201}Tl$ 심근관류 SPECT를 시행한 87명의 환자를 대상으로 연구 분석하였다. $^{201}Tl$ 심근관류 SPECT 시행 전날 전신 뼈 스캔 시행 여부에 따라 환자를 분류하였고 $^{201}Tl$ 심근관류 SPECT 촬영 시 이중 에너지 창을 이용하여 영상을 획득하였다. 획득한 영상에서 $^{201}Tl$ 창과 $^{99m}Tc$ 창에서 계수된 카운트의 비율을 전날 전신 뼈 검사의 시행 유무에 따라 비교 분석하였다. 실험에는 anthropomorphic torso phantom을 사용하였으며 심근($^{201}Tl$)과 심근 이외의 부분($^{99m}Tc$)에 각각 14.8 MBq, 44.4 MBq를 투여 하였다. 영상획득은 시간 간격을 두고 게이트 법 적용 없이 $^{201}Tl$ 심근관류 SPECT를 시행하여 얻었고 Xeleris ver 2.0551를 이용하여 공간 분해능을 측정 분석하였다. 수집한 환자 데이터에서 $^{201}Tl$ 창과 $^{99m}Tc$ 창에서 계수된 카운트 비율 비교 결과 전날 전신 뼈 스캔을 시행한 경우 Bone tracer 주입 후 12시간에서 24시간까지의 비율이 Ventri에서는 1:0.411 에서 1:0.114, Infinia에서는 1:0.249에서 1:0.079로 지수함수적으로 감소하며 시간 경과에 따라 유의한 차이(Ventri p=0.0001, Infinia p=0.0001)를 나타내었다. 또한 전신 뼈 스캔을 시행하지 않은 경우의 비율은 Ventri에서 평균 1:$0.067{\pm}0.006$, Infinia에서 1:$0.063{\pm}0.007$로 나타났다. Phantom 실험 후 공간 분해능 측정 결과는 $^{99m}Tc$의 첨가 여부와 시간 경과에 따라서 FWHM의 유의한 변화는 나타나지 않았다 (p=0.134). Anthropomorphic torso phantom을 이용한 실험과 환자 데이터 분석을 통해 bone tracer 주입 16시간 이 후에 시행된$^{201}Tl$ 심근관류 SPECT 영상은 $^{99m}Tc$에 의해 공간 분해능에 유의한 영향을 받지 않는다는 것을 확인하였다. 하지만 이는 영상의 질적 평가만 이루어진 것으로 환자의 피폭과 검사의 정밀도 및 정확도에 관한 연구가 추가로 필요한 실정이다. 추후 서로 다른 동위원소 사용에 따른 crosstalk contamination의 영향에 대한 정확하고 표준화된 유효성 검정으로 검사 간격에 대한 정확한 가이드라인 제시가 이루어져야 할 것이다.

  • PDF

의류 패턴 설계를 위한 삼차원 인체 체표면 스캔 데이터 활용에 관한 연구 (A Study on the Use of 3D Human Body Surface Shape Scan Data for Apparel Pattern Making)

  • 천종숙;서동애;이관석
    • 복식문화연구
    • /
    • 제10권6호
    • /
    • pp.709-717
    • /
    • 2002
  • In the apparel industry, the technology has been advanced rapidly. The use of 3D scanning systems fur the capture and measurement of human body is becoming common place. Three dimensional digital image can be used for design, inspection, reproduction of physical objects. The purpose of this study is to develop a method that drafts men's basic bodice pattern from scanned 3D body surface shape data. In order to pursue this purpose the researchers developed pattern drafting algorithm. The 3D scanner used in this study was Cyberware Whole Body Scanner WB-4. The bodice pattern drafting algorithm from 3D body surface shape data developed in this study is as follows. First, convert geometric 3D body surface data to 3D polygonal mesh data. Second, develop algorithm to lay out 3D polygonal patches onto a plane using Auto Lisp program. The polygon meshes are coplanar, and the individual mesh is continuously in contact with next one The bodice front surface shape data in polygonal patches form was lined up in bust and waist levels. The back bodice was drafted by lining up the polygonal mesh in scapula, chest, and waist levels. in the drafts, gaps between polygons were formed into the darts.

  • PDF

갑상선암 환자에서 전절제술 후 I-131 치료에서 미만성 간침착 정도의 분석 (Analysis of Diffuse Hepatic Visualization after Iodine-131 Treatment in Patients with Thyroid Carcinoma)

  • 정진형;배금석;강성준
    • 대한두경부종양학회지
    • /
    • 제16권2호
    • /
    • pp.206-211
    • /
    • 2000
  • Objectives: Any uptake of I-131 after total thyroidectomy means the remant thyroid tissue or distant metastasis of the thyroid cancer. However diffuse hepatic uptake of I-131 without abnormal uptake was showen in many cases on I-131 whole body scan. The aim of this study was to classify the liver uptake after I-131 scan and to evaluate the analysis of this finding. Materials and Methods: Between 1982 and 1998, 104 patients(l4 males, 90 females) with normal liver function underwent I-131 scan after total thyroidectomy. Prospectively we reviewed the films of the whole body scan and analysed the correlations between results of radioiodine uptake, pathologic diagnosis, prognostic factors, lymphatic metastasis, and thyroid function test. Result: Diffuse hepatic uptake was found in 44 of 104(42%) patients. 10 of 39(26%) patients on I-131 100mCi, and 34 of 63(54%) on I-131 150mCi showed hepatic uptake. 52 of 104(50%) patients was locally invasive thyroid cancer. The rate of the hepatic uptake was no significant differences with the thyroid hormone levels(T3, Free T4) and thyroglobulin between uptake group and non-uptake group. Conclusion: The rate of I-131 uptake was high in high-dose radioiodine treatment group. However, we can not find any correlation among the thyroid functions, the extent of metastasis or the extent of local invasion. We need further study to find out the causes of the hepatic uptake of I-131 after total thyroidectomy, besides liver metabolism of I-131 attached thyroid hormones.

  • PDF

Evaluation of Therapeutic Monitoring of Prostate Cancer (PCa) using [18F]Florastamin, Diagnostic Radiopharmaceutical for PCa: Non-clinical Ex vivo Whole-body Autoradiographic Analysis

  • Min Hwan Kim;Kyongkyu Lee;Hee Seup Kil;Soon Jeong Kwon;Yong Jin Lee;Kyo Chul Lee;Dae Yoon Chi
    • 대한방사성의약품학회지
    • /
    • 제9권1호
    • /
    • pp.17-21
    • /
    • 2023
  • In this study, we evaluated the targeting of prostate cancer (PCa) using [18F]Florastamin in non-clinical study, for the purpose of therapeutic monitoring of [177Lu]Ludotadipep, a therapeutic radiopharmaceutical for PCa, [18F]Florastamin/[177Lu]Ludotadipep was co-administered to a single-individual prostate tumor bearing mouse model, mimicking clinical condition. Considering the difference in half-life of the two isotopes (18F or 177Lu), image scan of whole-body autoradiography was performed at 24 or 48 h after preparation of frozen section, respectively. Then, it was confirmed whether they showed the same targeting efficiency for the area of tumor. A tumor xenograft model was prepared using PSMA-overexpressing PC3-PIP prostate cancer cells. [18F]Florastamin [111 MBq (3 mCi) in 100 µL]/177Lu]Ludotadipep [3.7 MBq (100 µCi) in 100 µL] was co-administered through the tail vein, and 2 hours after administration, the mice were frozen, and after freezing for 24 hours, whole-body cryosection was performed at 24 h after freezing. Image scanning using cryosection was performed after 24 or 48 hours after freezing, respectively. In the scan image after 24 hours, tumor uptake of [18F] Florastamin/[177Lu]Ludotadipep were simultaneously observed specific uptake in the tumor. In the scan image after 48 hours in the same section, signal of 18F was lost by decay of radioisotope, and specific uptake image for [177Lu]Ludotadipep was observed in the tumor. Uptake of [177Lu]Ludotadipep was specific to the same tumor region where [18F]Florastamin/[177Lu]Ludotadipep was uptake. These results suggested that [18F]Florastamin showed the same tumor uptake efficiency to PCa as [177Lu]Ludotadipep, and effective therapeutic monitoring is expected to be enable using [18F]Florastamin during [177Lu]Ludotadipep therapy for PCa.

갑상선암 환자에서 관찰된 뇌수막종의 위양성 옥소 섭취 (False-positive I-131 Uptake in Meningioma)

  • 정신영;서지형;배진호;황정현;안병철;이재태;이규보
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.272-273
    • /
    • 2004
  • We experienced a case with meningioma showing false positive I-131 uptake. A 55-years old female patient underwent high dose (150 mCi) radioactive iodine therapy to ablate remnant tissue after total thyroidectomy for papillary thyroid cancer. in addition to intense tracer uptake in thyroid bed, there was mild but focal abnormal uptake in left frontal lobe of the brain on post-therapy I-131 whole body scan. Subsequent brain MR imaging showed single mass lesion in left frontal lobe and the mass was resected under the impression of brain metastasis of thyroid carcinoma. Pathologic report confirmed meningioma from the surgical specimen.

Lower-body figure analysis of Chinese adult women

  • Cha, Sujoung
    • 복식문화연구
    • /
    • 제22권6호
    • /
    • pp.965-978
    • /
    • 2014
  • To determine the parameters to be considered when designing lower-body apparel, we analyzed the lower-body figures of adult women in their early 20s from Shanghai, China, using 3-dimensional whole body scanner. Thirty-nine lower-body-related measurements were used to analyze the figures of 210 Chinese women. Obesity and height of the lower body, length from waist to crotch, shape of abdomen, and leg bone length were analyzed. Factor analysis was performed and the results were classified into three clusters. The first cluster describes the obesity of the lower body, the second denotes small hip measurement, and the third describes slim and long legs. This is the first study to quantify figure analysis of the lower body of Chinese women using 3-dimensional body measurements. The findings of this study will provide concrete information regarding crotch width, crotch length, inseam, outseam, waist slope, etc., for designing trouser patterns for Chinese adult women.

갑상선암 환자에서 방사성 옥소로 오염된 목도리에 의한 위양성 소견 (False-positive I-131 Scan by Contaminated Muffler in a Patient with Thyroid Carcinoma)

  • 서한경;김민우;정환정;손명희
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권1호
    • /
    • pp.51-52
    • /
    • 2006
  • A 39-year-old female patient who had undergone a total thyroidectomy for a papillary thyroid carcinoma underwent a whole body scan with I-131. The I-131 scan was performed 72 hours after administering 185 MBq (5 mCi) of an I-131 solution. The anterior image of the head, neck, and upper chest showed multiple areas of increased uptake in the mediastinal area considering of functional metastasis. However, radioactivity was not evident in the image taken after removing her clothes and muffler. The image obtained after placing the muffler on the pallet showed that the radioactivity was still present. It is well known that artifacts on an I-131 scan can be produced by styling hair sputum, drooling during sleep, chewing gum, and paper or a cloth handkerchief that is contaminated with the radioactive iodine from either perspiration or saliva. This activity might be mistaken for a functional metastasis. Therefore, it is essential that an image be obtained after removing the patient's clothes. In this study, artifacts due to a contaminated muffler on the I-131 scan were found. These mimicked a functional metastasis of the mediastinal area in a patient with a papillary thyroid carcinoma.

유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가 (Usefulness of Prone Position on PET-CT in Breast Cancer)

  • 박훈희;김세영;김정열;박민수;임한상;정석;강천구;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.44-48
    • /
    • 2008
  • 유방암은 FDG PET-CT에서 예민도는 80~96%, 특이도는 75~95% 정도이며, 유방촬영(mammography) 소견상 판단이 어려운 수진자에게 매우 유용하며, 검진으로서의 조기 암 검출을 충분히 기대할 수 있다. PET-CT에서 대부분의 검사는 앙와위(supine position)으로 검사되어 전신검사(whole body scan)에서 원형으로부터 변형된 유방영상을 획득된다. 반면에 보정구를 이용하여 복와위(prone position)으로 영상을 획득할 경우, 유방을 중력에 의존하여 보다 원형에 가깝게 표현함으로써 영상의 진단가치를 높일 수 있기에 그 유용성을 평가하였다. 유방암으로 의심되거나 확진 된 여성 환자 30명을 대상으로 하였으며, $^{18}F$-FDG 주사한 뒤 60분 후 supine position으로 whole body PET-CT scan 시행 후, 보정구를 이용하여 prone position으로 병변에 대한 추가검사(lesional scan)를 시행하였다. 각각 획득된 영상은 핵의학과 의사로부터 blind test를 하였고, PET-CT 영상의 SUV를 측정하여 분석하였다. 30명 중 27명의 환자에게서 prone자세가 진단 용이성과 정확한 판별률이 높았으며, 나머지 3명의 경우는 병소가 1 cm 이하의 크기로 인하여, MRI상에는 나타났지만 PET-CT에서는 진단에 의미있는 관찰을 할 수 없었다. supine position과 비교하여 prone position은 구조물의 중력에 의한 변형수치가 낮아, 병변의 구별이 곤란한 경우 명확하게 감별되었다. 각 자세에서 SUV분석은 유의수준 0.004로 유의하였다. Supine position을 통한 PET-CT 전신검사 후의 보정구를 이용한 prone position로 병변에 대한 lesional scan은 두 자세의 비교가 모두 가능하였으며, 경우에 따라 결정적으로 진단에 영향을 주었다. 두 가지 자세의 영상비교에 있어 prone position이 원발성(primary) 병변의 진단은 물론, 미세전이(micrometastasis)의 검출이 가능하였다. 이러한 prone position을 기반으로 구조적인 문제를 정량적 분석과 함께 극복한다면 병변의 진단에 있어 보다 유용한 진단적 정보를 얻을 수 있으리라 사료된다.

  • PDF