• 제목/요약/키워드: Whole body frame

검색결과 35건 처리시간 0.024초

Study on The Development of A New Whole Body Fame

  • Chung, Jin-Bum;Suh, Tae-Suk;Chung, Won-Kyun;Choe, Bo-Young;Lee, Hyoung-Koo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.136-137
    • /
    • 2002
  • We have been researching upgrade version of a stereotactic whole body frame, used for evaluating daily setup accuracy of the patient positioning during fractionated extra-cranial stereotactic radiotherapy. Currently, we are focusing on the development of a new stereotactic whole body frame, and then will handle organ movement produced by breathing at the next stage. MeV-Green is chosen for the best immobilizer possible and the epoxy board is for the frame with the dimension of 110 em in length, 50 cm in width in order to maximize transmission rate of the beam from lateral or posterior direction and to fit CT and PET scanners with an aperture of 55 cm at least. The key point of an upgraded stereotactic whole body frame will be set on the collision-free rotation of the gantry with the frame, and the development of the checking structure for the daily patient repositioning regarding internal target.

  • PDF

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

확장형 알루미늄 압출형재 적용에 관한 연구 (Study on Application of Large-Scale Aluminium Extruded Material)

  • 이재호;문인철;서수호;장영봉
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2672-2678
    • /
    • 2011
  • 철도차량의 차체 구조는 초기의 전(全) 목제에서 강제 후레임과 목제 차체의 조합, 리벳으로 결합한 전(全)강제차체, 전(全) 용접결합의 모노코크(monocoque)차체로 변천해 왔다. 구체의 재료 또한 Mild Steel이 많이 사용되어 왔으나, 가볍고 내식성이 우수한 경량 스테인레스 구체와 알루미늄 구체의 적용 비율이 급격히 높아지고 있다. 구조적으로는 종래의 골조와 외판으로 구성된 싱글 스킨 구조인 SSD (Sheet_Stringer Design)에서, 알루미늄 구체와 같이 대형 중공압출형재로 구성된 전(全)더블스킨 구조인 AED(All Extrusion Design)가 실용화되고 있다. 종래의 알루미늄 차체는 소형 압출재로 제작되어 용접에 의한 열영향을 받는 범위가 매우 크고 매우 취약한 특성 때문에 나타나는 용접결합 부분의 강성 저하가 많은 문제점을 일으켰다. 본 연구에서는 확장형 알루미늄 압출형재를 사용하여 부재 수를 감소시킴으로서 용접 공수를 줄이고 결합부의 용접 집중을 최소화 하여 품질 및 차체 강성을 향상 시킬 수 있는 방안을 제시하였다.

  • PDF

3차원 전신 정위 방사선 치료 장치의 개발 (Development of the Whole Body 3-Dimensional Topographic Radiotherapy System)

  • 정원균;이병용;최은경;김종훈;안승도;이석;민철기;박참복;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제10권2호
    • /
    • pp.63-71
    • /
    • 1999
  • 입체조형 치료와 전신 방사선 수술에의 이용을 목적으로 3차원 전신 정위 방사선 치료 장치를 개발하였다. Couch 위에 놓을 수 있는 전신 정위 치료판을 제작하여 방사선 비투과성 카테타 선을 이용하여 치료판 위에 좌표계를 설치하고, MeV-Green(전성 물산, 한국)으로 고정틀을 만들어 환자 자세를 고정시키고, 플라스틱 봉과 봉 지지판을 이용하여 고정틀을 고정하였다. 이러한 설계, 제작으로 입체 조형 치료 등에서 갠트리 회전에 의한 기하학적 제약을 최소화하고 방사선 조사 투과율 이 특정한 방향에서 영향을 받는 문제점을 해소하였다. CT 영상을 통해 치료 표적의 위치를 파악하고 치료판 기준점에 대하여 좌표화하여 모의 치료시와 방사선 치료시의 환자 자세 변화 오차를 줄였다. 3대의 CCTV 카메라를 사용하여 환자 자세 변화를 감지, 수정함으로써 체표변의 외곽선으로 부터 setup 오차를 최소화 할 수 있었다. 치료 효용성을 높이기 위해 이러한 과정을 모니터를 보면서 실시간으로 처리 할 수 있도록 하였고, IDL(Interactive Data Language, RSI, U.S.A.)을 사용하여 image subtraction 방식으로 환자 자세 변화를 가시화하여 오차를 줄이도록 하였다. 내부 장기 움직임에 따른 표적의 움직임을 추적할 목적으로 rotating X-ray 장치를 제작하였다. Landmark 나사를 표적주위 뼈나 표적중심에 삽입하여 이 rotating X-ray 장치를 이용해서 anterior, lateral 두 방향에서 얻은 영상 정보로부터 marker 에 대한 표적의 위치 변화를 가시화 하여 내부 표적의 움직임에 따른 setup 오차를 줄였다. CT 모의치료를 할 수 있도록 IDL 을 이용하여 PC용 모의치료 프로그램을 GUI 환경에서 구현하였고 이 프로그램을 통해서 치료 계획을 위해 CT 에서 수집된 영상정 보를 이용하여 표적을 포함한 장기들의 그래픽 처리, 편집, 전송 등의 작업을 수행하도록 하였다.

  • PDF

도로 배수용 그레이팅 구조의 개선에 관한 연구 (A Study on the Development of Grating Structure for Drain of Water)

  • 김기선;이은종
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.531-538
    • /
    • 2006
  • 그레이팅은 아스팔트 도로에 설치하여 배수를 할 수 있는 구조물이다. 본 논문에서는 그레이팅의 구조를 개선하여 토사의 쌓임을 방지 할 수 있는 신제품을 제안한다. 기존 제품은 프레임에 오물이 쌓여 있어 평상시 해충이나 악취가 발생하며 우천 시 배수가 원활하지 못해 물이 고이는 현상도 빈번할 뿐 아니라 역류하는 현상이 발생한다. 또한 기존 그레이팅이 프레임과 본체를 일체형으로 설치하여 파손 시 전체를 교체하여야 하는 단점이 있다. 본 연구는 그레이팅 본체와 프레임을 분리시킨 구조로 프레임을 멘 홀에 시멘트와 함께 기초공사 하여 고정한 후 그레이팅 본체는 장착탈이 가능한 구조로 개발하였다. 또한 분실 방지용 지그도 설치하여 이를 개선하였다.

  • PDF

COLLAPSE CHARACTERISTICS OF ALUMINUM EXTRUSIONS FILLED WITH STRUCTURAL FOAM FOR SPACE FRAME VEHICLES

  • Kim, B.J.;Heo, S.J.
    • International Journal of Automotive Technology
    • /
    • 제4권3호
    • /
    • pp.141-147
    • /
    • 2003
  • For improving high-safety, convenience, and ride comfort, the automotive design suffers from radical increase of the weight, the recycling-related rules, regulations on the waste gas, and environmental protection of the resources. Among them, it is well known that the weight increase is the most critical. Thus, in order to minimize the weight of the body-in-white that takes up 20-30% of the whole weight of the automobile, most automotive manufacturers have attempted to develop the aluminum intensive body-in-white using aluminum space frames. In this research, the crush test and simulation for aluminum extrusions are performed to evaluate the collapse characteristics of that light weighted material. Also. the same test and simulation was done for aluminum extrusions filled with structural foam. Then, these results are analyzed and compared. From these studies, the effectiveness of structural foam is evaluated in improving automotive crashworthiness. Finally, the design strategy and guideline of the structural form are suggested in order to improve the crashworthiness for aluminum space frame in the vehicle.

전신 정위 고정장치 제작과 임상효과에 대한 연구 (The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.30-38
    • /
    • 2004
  • 목적: 방사선 치료 시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 Setup 오차를 감소시키고 환자 전신에 산재한 병소를 위치화하고 좌표화할 수 있는 전신 정위 고정장치 제작과 제작한 고정장치에 대한 고정효과 및 재현성을 나타내는 환자 자세의 Setup 오차를 평가하였다. 대상 및 방법: 자체 제작한 고정장치는 크게 기본판(base plate)과 고정틀(Immobilizer), Vacuum cushion, 벨트로 이루어진다. 기본판은 50${\times}$130${\times}$1 ㎤ 베크라이트로 고정틀은 견고한 아세탈 재질을 사용하여 제작하였다. 초기의 Lax frame의 경우, side panel에 부착되어 있는 좌표계(coordinates)를 기본판 바닥에 radiopaque catheter wire를 사용하여 N 타입으로 새겨서 넣어 위치측정이 가능한 좌표계로 적용할 수 있도록 하였다. 제작된 고정장치에 대한 성능실험으로 방사선 투과율 측정 실험과 가상표적을 부착한 지원 환자를 대상으로 표적에 대한 위치측정실험이 수행되었다. 그리고 CCTV 카메라와 Digital Video Recorder (DVR)를 이용하여 획득된 환자 영상을 Matlab 프로그램으로 환자 자세에 대한 Setup 오차를 분석하였다. 결과: 전신 정위 고정장치는 CT 촬영과 방사선치료 시 사용 가능성에 중점을 두고 제작되었다. 이 고정장치의 구조는 갠트리의 회전각의 변화에 따라 충돌하지 않게 제작되었고 측면으로 경사지게 입사되는 빔의 투과율을 최대화할 수 있게 제작되었다. 고정틀의 고정효과를 높여주는 고정벨트는 입사된 빔의 방향에 방해되지 않게 제작되었다. 고정장치에 대한 방사선 투과율은 10과 21 MV의 에너지에서 95, 95%로 측정되었고 지원 환자에 부착한 가상 표적의 위치는 CT 촬영으로 파악할 수 있었다. Matlab 프로그램으로 분석한 setup 오차는 흉부의 측면과 중심부위에서 3.69$\pm$1.60, 2.14$\pm$0.78 mm이고 복부의 측면과 중심부위에서 7.11$\pm$2.10, 6.54$\pm$2.22 mm이며 여자 환자 경우, 가슴 측면의 Setup 오차는 6.33$\pm$1.55 mm으로 측정되었다. 결론: 전신 정위 고정장치의 제작과 실험을 통해 extra-cranial 암에 대한 방사선수술에서 매우 실용적이고 유용하게 사용될 것으로 사료되며 표적 위치 결정과 환자 고정 도구로서 사용될 것이다. 더 많은 환자 치료자세의 Setup 오차 측정이 수행되면 정확한 환자의 Setup 오차의 결과를 향상시킬 수 있을 것으로 기대된다.

  • PDF

학령전기 여아의 체형특성과 유형분석 -상반신 체형을 중심으로- (Somatometric Characteristics and Classification of Early Elementary Schoolgirls -Focusing on the Upper Body-)

  • 장정아;권미정;배은아
    • 한국의류학회지
    • /
    • 제26권5호
    • /
    • pp.573-581
    • /
    • 2002
  • This study was done to classify children's somatotypes and to provide the fundamental data or their clothing sizing system for the purpose of designing patterns fur children's wear and standardizing sizes of ready-made clothes. The sampling was done for 7-8 years-old-girl living in Pusan and Kyungsangnam-do. Data from each girl comprises 33 anthropometic measurments and 7 photogrphic measurments, based on the somatometric characteristics of girls which I had obtained. Factor analysis, cluster analysis, discriminant analysis were performed for statistical analysis of the data. Seven factors which explain 76.49% of the whole variances were extracted. The thirst and second factors which explain more than 70% of the whole variances represent 'horizontal size 'and 'vortical size', which characterize most aspects of the body shape of the subjects. On the basis of the cluster analysis, three different upper body types were categorized. Type 1 has quite long surface length of the upper body and rising shoulders and are close to the averages of this age group. Type 2 has highest stature, biggest frame, dropped shoulders and surface length of the upper body similar to the type 1. Type 3 has shortest stature, smallest frame and sloping shoulders. According to the analysis to discriminate somatotypes of the upper body by this age group, the discriminative items in discriminant function are follows. As this group, waist circumference of discriminant function 1 and front length and length between both shoulder points of discriminant function 2 have large coefficient values.

인체 모델 생성을 위한 등고선 삼각분할 기반의 3차원 전신 스캐너 개발 (Development of a 3D Whole Body Scanner for Reconstructing Human Body based on Contour Triangulation Technique)

  • 최영규;구본기;최병태
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제30권7_8호
    • /
    • pp.397-407
    • /
    • 2003
  • 인간의 신체에 대한 정확한 3차원 표면모델을 추출할 수 있는 기술에 대한 요구와 관심이 최근 멀티미디어 등 다양한 응용 분야에서 증폭되고 있다. 본 논문에서는 인체의 ,3차원 모델을 효율적으로 추출하기 위한, 3차원 스캐너를 소개하였으며, 취득된 3차원 정보로부터 등고선(Wire-frame Contour)을 안정적으로 생성하는 반자동 등고선 생성 방법을 제안하였다. 또한 생성된 등고선으로부터 3차원 표면모델을 추출하기 위한 표면 삼각분할 알고리즘을 제안하였다. 실험을 통해 개발된 시스템과 제안된 방법이 안정적이고 효과적으로 인체의, 3차원 표면모델을 생성하는 것을 확인할 수 있었다.

배수용 그레이팅 프레임의 개선에 관한 연구 (A Study on the Development of Grating Frame for Drain Water on Road)

  • 이은종;김기선
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.713-720
    • /
    • 2007
  • 그레이팅은 아스팔트 도로에 설치하여 배수를 할 수 있는 구조물이다. 본 논문에서는 그레이팅의 구조를 개선하여 토사의 쌓임을 방지 할 수 있는 개선품을 제안한다. 기존 제품은 프레임에 오물이 쌓여 있어 평상시 해충이나 악취가 발생하며 우천 시 배수가 원활하지 못해 물이 고이는 현상도 빈번할 뿐만 아니라 역류하는 현상이 발생한다. 또한 기존 그레이팅이 프레임과 본체를 일체형으로 설치하여 파손 시 전체를 교체하여야 하는 단점이 있다. 본 연구는 그레이팅 본체와 프레임을 분리시킨 구조로 프레임을 멘 홀에 시멘트와 함께 기초공사 하여 고정한 후 그레이팅 본체는 장착탈이 가능하도록 한 구조로 개발하였다.

  • PDF