• 제목/요약/키워드: Whole Blood

검색결과 994건 처리시간 0.031초

Correlation Between Total Mercury and Methyl Mercury-In Whole Blood of South Korean

  • Jung, Seon A;Chung, Dayoung;On, Jiwon;Moon, Myeong Hee;Lee, Jeongae;Pyo, Heesoo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1101-1107
    • /
    • 2013
  • In this study, total mercury and methyl mercury in whole blood of Korean was analyzed so as to investigate the correlation between total mercury (T-Hg) and methyl mercury (Me-Hg). 4000 whole blood samples were divided in four groups, according to T-Hg concentration in percentile: group I (p25-p50), group II (p50-p75), group III (p75-p95) and group IV (p95-p100). 100 samples were randomly selected from the each group, and Me-Hg concentration was measured. T-Hg concentration in whole blood was analyzed using a Direct Mercury Analyzer-80 and obtained limit of detection (LOD) was $0.2{\mu}gL^{-1}$. Me-Hg concentration was analyzed with ethylate derivatization using headspace-gas chromatography-mass spectrometry, and obtained LOD of methyl mercury was $0.5{\mu}gL^{-1}$. The geometric means of T-Hg and Me-Hg were $6.35{\mu}gL^{-1}$ and $4.44{\mu}gL^{-1}$, respectively, and 71.91% of T-Hg was presented as Me-Hg.

회첨 엑기스의 혈압에 미치는 영향(I) (Effects of Siegesbeckiae Herba Extracts on the Blood Pressure of Rabbits(I))

  • 김성원;고석태
    • 약학회지
    • /
    • 제24권2호
    • /
    • pp.101-110
    • /
    • 1980
  • 희첨(Siegesbeckiae Herba)은 진득찰(Siegesbeckiae pubescens Makino)의 잎을 말하며 한방에서 중풍, 전신마비, 반신불수, 부종등에 사용되어 왔다. 이에 관한 연구로는 한등이 diterpene계의 불합물을 분리하였고 이 diterpene계중의 한 성분이 실험적 신성 고혈압을 유기한 백서에 항고혈압작용이 있음을 보고한바 있으나 이의 고혈압 활료제로의 실용성 여부에 관하여서는 확인된 바가 없어 고혈압 치료제 개발의 일환으로서 화학적 성분 연구에 우선하여 약리학적으로 그 본태를 파악하고저 수성 및 알콜성 엑기스를 축출하여 가토에 대하여 이 실험을 시행하였다.

  • PDF

IN-VITRO CHARACTERIZATION OF THE THROMBOTIC POTENTIAL OF WHOLE BLOOD USING AN IMPEDANCE METHOD

  • Granaderos, Carlo;Park, Joong-Chun;Pak, Bock-Choon;Kim, Cheol-Sang;Cho, Young-I
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2785-2790
    • /
    • 2007
  • This study presents an impedance method of in-vitro characterization of the thrombotic potential of whole blood. Whole blood samples of 0.2 cc were put into a micro-cell with embedded three electrodes immediately after venepuncture at $37^{\circ}C$. Anti-coagulated blood samples were also collected for hematocrit and blood viscosity analyses. The rate of change of electron flow was measured, which indicates the inverse of the thrombotic potential. A sudden decrease in the rate of change of electron flow was observed at a time equal to approximately 110 seconds. This sudden decrease was significantly delayed in anti-coagulated samples. After the sudden decrease, the rate continued to decrease, reaching a minimum value in unadulterated samples while the change in the rate in the anti-coagulated ones was found rather moderate. Based on these preliminary findings, the present method may be of used as a new tool for the diagnosis of the thrombotic potential of whole blood.

  • PDF

황기의 혈압강하 작용에 관한 연구 (A Study on the Hypotensive Action of Astragali Radix Water Extract in the Rabbit)

  • 임동윤
    • 약학회지
    • /
    • 제23권2호
    • /
    • pp.69-80
    • /
    • 1979
  • Effects of Astragali Radix Water Extract (ARWE) on the blood pressure were investigated in the whole rabbit and the spinalized rabbit. ARWE, when administered into the ear-vein or lateral ventricle, produced a fall in the blood pressure in the whole rabbit, but intravenous ARWE in the spinalized rabbit did not elicite the hypotensive action. Pretreatments with chlorisondamine, guanethidine, phentolamine and cyproheptadine in the whole rabbit weakened the depressor action of ARWE. The hypotensive action of the whole rabbit to ARWE was not influenced by the pretreatment of the animals with diphennylhydramine, propranolol, and vagotomization, whereas inhibited by atropine. ARWE did not affect the pressor response by angiotensin. However, it enhanced the hypertensive action by norepineprine and reduced the elevation in the blood pressure by carotid occlusion in the whole rabbit. These experimental observations suggest that ARWE may cause the depressor response via mechanisms of the central sympathetic blocking action, cholinergic action by peripheral origin and serotonin-like action.

  • PDF

목통(木通) Ethanol Extract의 혈압강하작용(血壓降下作用)에 관(關)한 연구(硏究) (A Study on the Hypotensive Action of Akebiae Lignum Ethanol Extract in Rabbits)

  • 강호연
    • Journal of Pharmaceutical Investigation
    • /
    • 제9권2호
    • /
    • pp.22-30
    • /
    • 1979
  • Effects of Akebiae Lignum, whose scientific name is Akebia quinata Decaisne, on the blood pressure were investigated with EtOH extract in whole and spinal rabbits. Akebia Lignum EtOH extract (AEE), when given intravenously, produced a fall in blood pressure not only in whole rabbit but also in spinal rabbit and AEE administered into a lateral cerebral ventricle of whole rabbit did not elicit a fall in blood pressure. The depressor responses of the whole rabbit to intravenous AEE were weakened by treatment of the animals with atropine and chlorisondamine but not by vagotominijation, phentolamine avil, and then the depressor action causing by AEE in the whole rabbit was not affected by pretreatment of physostigmine which is cholinesterase inhibitor and of hemicholinium which blocks acetylcholine synthesis by interfering with choline uptake in nerves. These observations suggest that the hypotensive action of AEE of which component is not affected by cholinesterase is due to direct action at parasympathetic receptor.

  • PDF

Reference Values of Whole Blood Viscosity and Its Correlation with Hematology and Serum Chemistry in Beagle Dogs

  • Koh, Jun;Lee, Dong-bin;Lee, Dong Han;Kim, Nam Soo
    • 한국임상수의학회지
    • /
    • 제35권3호
    • /
    • pp.77-82
    • /
    • 2018
  • The aim of this study was to measure whole blood viscosity (WBV) and then to establish its reference values and identify correlation between WBV and hematology or serum chemistry in beagle. The experiment was made up of 82 healthy beagle dogs. Jugular vein blood samples (10 ml) were collected. WBV (cP) measured within 4 hours after collection by U-shaped scanning capillary-tube viscometer ($BVD-PRO1^{(R)}$) which is capable of measuring yield stress and viscosity of whole blood continuously over a wide range of shear rates from $1s^{-1}$ to $1000s^{-1}$ is new type of capillary tube viscometer and calculates viscosity using Casson fluid model. Measured values of WBV, Complete blood cell count, serum chemistry were analyzed by RM-ANOVA test. Mean diastolic and systolic WBV (cP) were $29.032{\pm}6.137$ and $4.528{\pm}0.865$. Bodyweight (BW), Red blood cell count (RBC), Hemoglobin (HGB), Hematocrit (HCT), Alkaline phosphatase (ALP), Cholestetol (CHOL), Total protein (TP), Globulin, Chloride (Cl), Fibrinogen, were statistically correlated with WBV over whole range of shear rates (p < 0.05). This study newly evaluated reference values of WBV by U-shaped viscometer in beagle. Correlation between WBV and BW, RBC, HGB, HCT, ALP, CHOL, TP, Globulin, Cl, Fibrinogen was presented.

혈액 세포의 고유자성을 이용한 마이크로 자기영동 세포분리기 (Magnetophoretic Microseparators for Separating Blood Cells Based on Their Native Magnetic Properties)

  • 정진희;한기호
    • 대한기계학회논문집B
    • /
    • 제32권11호
    • /
    • pp.856-862
    • /
    • 2008
  • This paper presents the characterization of a continuous magnetophoretic microseparator for separating white and red blood cells from peripheral whole blood cells based on their native magnetic properties. The magnetophoretic microseparator separated the blood cells using a high gradient magnetic separation (HGMS) method without the use of additives such as magnetic beads or probing materials. Experimental results show that the paramagnetic capture mode microseparator can continuously separate out 93.5% of red blood cells and 97.4% of white blood cells from diluted whole blood, and the diamagnetic capture mode microseparator can continuously separate out 89.7% of red blood cells and 72.7 % of white blood cells by using applying an external magnetic flux of 0.2 T using a permanent magnet.

도금업체 근로자의 공기중 크롬 노출 농도와 요 및 혈중 크롬 농도간의 상관성 (Relationship between Workers′ Exposure to Airborne Chromium and Blood and Urine Chromium Levels in Plating Process)

  • 이지태;신용철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.1-10
    • /
    • 2001
  • This study was performed to evaluate chromium in air and chromium concentrations in whole blood and urine of workers at chrome plating factories, and to determine the correlation between environmental and biological chromium levels. This study involved 29 workers as study group and 24 undergraduate students as control group. The geometric means(GM) of airborne hexavalent chromium and total chromium concentrations in the plating factories were 3.4 $\mu\textrm{g}$/㎥ and 10.8 $\mu\textrm{g}$/㎥, respectively. Hexavalent chromium levels in two of total 29 measurements exceeded the korean occupational exposure limit and the American Conference of Governmental Industrial Hygienists Threshold Limit Value(ACGIH-TLV) of 50$\mu\textrm{g}$/㎥. Only one sample for total chromium exceeded the Korea occupational exposure limits, the ACGIH-TLV, and the National Institute for Occupational Safety and Health Recommended Exposure Limits(NIOSH-REL) of 500 $\mu\textrm{g}$/㎥. The GM of chromium concentrations in blood and urine of workers exposed to chromium were 8.4 $\mu\textrm{g}$/L and 11.9 $\mu\textrm{g}$/L. The GM of chromium concentrations in blood and urine of workers exposed to chromium were 8.4 $\mu\textrm{g}$/L and 11.9 $\mu\textrm{g}$/L, respectively, whereas the chromium concentrations in blood and urine of the controls were 1.6 $\mu\textrm{g}$/L and 3.8 $\mu\textrm{g}$/L, respectively. There were statistically significant differences of blood and urine concentrations between study group and control group (p<0.01). The chromium concentrations in urine were most highly related to hexavalent chromium, concentration in air(r=0.642, p<0.01). Also, there was a relatively high correlation between the hexavalent chromium concentrations in air and chromium concentrations in whole blood(r=0.557, p<0.05). These results indicate that whole-blood chromium with urinary chromium could be an indicator of chromium body burden caused by exposure to chromic acid mist in plating operation.

  • PDF

방사성동위원소(放射性同位元素) $^{51}Cr$을 이용(利用)한 적혈구수명(赤血球壽命) 측정(測定)에 관(關)한 고찰(考察) -$^{51}Cr$-적혈구수명(赤血球壽命) 측정법(測定法)의 재평가(再評價)와 실혈(失血)이 수명측정(壽命測定)에 미치는 영향(影響)에 관(關)한 연구(硏究) (Study on the Measurement of $^{51}Cr-tagged$ Red Cell Survival - Reevaluation of its method & the effect of Blood loss on red cell suruival with $^{51}Cr$ -)

  • 최학용;고창순;이문호
    • 대한핵의학회지
    • /
    • 제4권2호
    • /
    • pp.55-66
    • /
    • 1970
  • Reappraisal measurements of apparent half survival time of red cell by $^{51}Cr$ method was made and effects of blood-letting over red cell survival were observed. The study was performed on 53 normal male subjects under three different experimental conditions. 1. Group 1 Mean $^{51}Cr$ red cell half survival by ACD wash method was 29.7 days. $T\frac{1}{2}$ of Ascorbic acid method was 29.0 days in group with 100 mg dose and 29.1 days in group with 50 mg dose respectively. There was no difference between these two methods in regards to red cell half survival. No difference were noted in amount of ascorbic acid administered. 2. Group 2 As daily amount of blood loss is increased the shortening of red cell half survival was noted. Rapid phase was seen when blood loss ranged 10 to 25 ml per day, while slow phase noted when more loss amounted 25 ml or more daily. Thus, it was clear that there was more than an exponential relation between $T\frac{1}{2}$ and the amount of blood loss. 3. Group 3 $T\frac{1}{2}$ measured by cpm per whole blood was within normal range and $T\frac{1}{2}$ measured by cpm per red cell mass showed shortening tendency when compared with the former in the group measured after blood loss (from 25 ml daily up to 100 ml daily in 10 days). In the group with rather constant blood loss of 100 ml daily for 10 consecutive days revealed the significant difference in two measurements (P<0.01). 4. $T\frac{1}{2}$ in non-steady state When red cell production is increased compared with red cell destruction, $T\frac{1}{2}$ measured by cpm per red cell mass being shorter than that by cpm per whole blood. Shortening of $T\frac{1}{2}$ measured by cpm per whole blood is more prominent. if red cell destrction is enhanced and exceeds production. 5. It is clear that when expressing red cell destruction rate, $T\frac{1}{2}$ measured by cpm per whole blood is more adequate and production more consistent with cpm red cell mass. 6. $T\frac{1}{2}$ measured during blood-letting, when corrected by amount of blood loss, it remains normal. It is erroneous to use conventional equational when measuring $T\frac{1}{2}$ in non-steady. $T\frac{1}{2}$ measured by cpm per whole blood is considred more applicable in clinical evaluation.

  • PDF