• Title/Summary/Keyword: Wet test

Search Result 790, Processing Time 0.027 seconds

The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system (접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향)

  • Ryu, Won-Il;Shon, Won-Jun;Baek, Seung-Ho;Lee, In-Han;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.385-396
    • /
    • 2011
  • Objectives: This study evaluated the effects of adhesion variables such as the priming concepts of canal wall and the curing modes of adhesives on the sealing ability of a resin-based root canal filling system. Materials and Methods: Apical microleakage of the Resilon-RealSeal systems filled with 3 different combinations of adhesion variables was compared with the conventional gutta-percha filling using a dye penetration method. Experimental groups were SEDC, Resilon (Resilon Research LLC) filling with self-etch RealSeal (SybronEndo) primer and dual-cure RealSeal sealer; NELC, Resilon filling with no etching, Scotchbond Multi-Purpose (3M ESPE) primer application and light-curing adhesive; and TELC, Resilon filling with Scotchbond Multi-Purpose primer and adhesive used under total etch / wet bonding and lightcure protocols. GPCS, gutta-percha filling with conventional AH26 plus sealer, was the control group. Results: The median longitudinal dye penetration length of TELC was significantly shorter than those of GPCS and SEDC (Kruskal-Wallis test, p < 0.05). In the cross-sectional microleakage scores, TELC showed significant differences from other groups at 2 to 5 mm from the apical foramen (Kruskal-Wallis test, p < 0.05). Conclusions: When a resin-based root canal filling material was used, compared to the self-etching primer and the dual-cure sealer, the total etch/wet-bonding with primer and light-curing of adhesive showed improved apical sealing and was highly recommended.

Wear Characteristics of Wheel/Rail Material under Dry and Wet Conditions (건식 및 수분조건에 따른 차륜/레일의 마모특성 평가)

  • Seo, Jung Won;Kwon, Suk Jin;Jun, Hyun Kyu;Lee, Dong Hyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.7
    • /
    • pp.541-549
    • /
    • 2016
  • Rolling contact fatigue and wear on rails are inevitable in railway operations due to excessive wheel-rail contact stress. The wear is influenced by vehicle speed, contact pressure, environmental conditions, and many other factors. Speeding on a curved track causes many problems such as wear on the gauge of the rail and rolling contact fatigue. Managing environmental conditions can reduce problems on the wheel and rail interface. In this study, the wear characteristics of wheel and rail materials were investigated by twin-disc testing using various parameters. The results of the wear test indicated that the wear rate under dry conditions was larger than that under wet conditions. We found that contact fatigue damage occurred on the rail in dry conditions, however, the surface of the specimen under water remained smooth. Also, the friction coefficient in dry conditions was larger than in wet conditions.

Study on the Humidity Effect on Gas turbine Engine Performances (습도가 엔진성능에 미치는 영향에 대한 실험적 고찰)

  • Lee, Bo-Hwa;Lee, Kyung-Jae;Yang, Soo-Seok;Kim, Chun-Taek
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.98-104
    • /
    • 2010
  • The moisture in the atmosphere exerts a lot of influence upon Gas turbine engine performances. There is a noticeable influence of wet air at the summer sea level, high flight mach number and low engine rpm increasingly. An altitude Engine Test Facility is used to accomplish the engine performance tests at dry air condition and wet air condition, through which engine performance results is revealed. Also, Gas turbine Simulation Program is used to predict the variation of engine performance due to inlet humidity. In the result, net thrust and specific fuel consumption measured -2.826% and 1.325%, respectively at wet air condition compared to dry air condition.

Evaluation of Contaminant Concentrations in Wet and Dry Seasons during Pump-and-Treat Pilot Tests

  • Jeon, Woo-Hyun;Lee, Jin-Yong;Kwon, Hyung-Pyo;Jun, Seong-Chun;Cheon, Jeong-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.18-31
    • /
    • 2013
  • This study was performed to examine use of the pump-and-treat method for remediation of TCE, CF and CT in groundwater contaminated by DNAPL. The Woosan industrial complex is located in Wonju, about 120 km east of Seoul, Korea. Two pumping wells (KDPW7 and KDPW8) and five monitoring wells (KDMW7, KDMW8, KDMW9, KDMW10, and SKW2) were installed for the test. An asphalt laboratory is a main source of the extensive subsurface contamination at this site. To evaluate change in the concentrations of TCE, CF, and CT in groundwater in the study area, three rounds of pump-and-treat pilot tests were performed (6 July to 6 August, 22 August to 6 September, and 19 September to 2 December in 2011). The groundwater levels and the concentrations of TCE, CF, and CT exhibited negative correlations in the wet season but positive correlations in the dry season, which suggests that the TCE concentrations were mainly controlled by dilution through rainfall during the wet season and by residual TCE, CF, and CT in the unsaturated zone during the dry season. These possibilities should be considered in the full-scale remediation plan.

Comparison of Precipitation Characteristics using Rainfall Indicators Between North and South Korea (강수지표를 이용한 남·북한 강수특성 비교)

  • Lee, Bo-Ram;Chung, Eun-Sung;Kim, Tae-Woong;Kwon, Hyun-Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2223-2235
    • /
    • 2013
  • This study aimed to understand temporal and spatial trends of rainfall characteristics in South and North Korea. Daily rainfall observed at the 65 stations in South Korea between 1963 and 2010 and the 27 stations in North Korea between 1973 and 2010 were analyzed. Rainfall Indicators for amount, extremes, frequency of rainfall were defined. Province-based indicators in the recent 10 years (i.e., between 2001 and 2010) were compared to those in the past (i.e., between 1963/1973 and 2000 for South/North Korea). In the recent 10 years, all the indicators except for the number of wet days (NWD) and 200-yr frequency rainfall (Freq200) increased in South Korea and all the indicators except for the annual mean daily rainfall over wet days (SDII) and annual total rainfall amount (TotalDR) decreased in North Korea. Furthermore, we performed the Mann-Kendall trend test based on the annual indicators. In some stations, decreasing trends in the past and increasing trends in the recent 10 years were found, and such opposite trends between two periods suggest he limitation in predicting and analyzing the rainfall characteristics based on the average. Results from this study can be used in analyzing the impact of climate change and preparing adaptation strategies for the water resources management.

THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS (복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구)

  • Jeon, Cheol-Min;Kwon, Hyuk-Choon;Lee, Chung-Sik;Lee, Myung-Jon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF

Detection of the Carcinogenic Liver Fluke Opisthorchis viverrini Using a Mini Parasep SF Faecal Parasite Concentrator

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Tongtawee, Taweesak;Matrakul, Likit;Panpimanmas, Sukij;Wakkuwattapong, Parichart;Loyd, Ryan A;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.373-376
    • /
    • 2016
  • The Mini Parasep SF fecal parasite concentrator (MPSFC) is a new modification of the closed concentration system, which can easily be adopted in any routine clinical pathology laboratory. Here we describe our experience with the system in diagnosing Opisthorchis viverrini. A total of 199 fecal samples was submitted for routine examination in the clinical pathology laboratory of Suranaree University of Technology hospital, Nakhon Ratchasima province, Thailand, during August to October 2015. Out of all samples examined, 10 (5.03%) were positive with intestinal parasites including O. viverrini (2.01%), followed by Strongyloided stercoralis (1.51%), Hookworm (0.5%), Taenia spp. (0.5%), and Entamoeba coli (0.5%). Regarding the distribution of intestinal parasites in relation to the methods used, and found that 4 samples (2.01%) were positive using the direct wet smear method while 10 (5.03%) were positive with the Mini Parasep SF method; the difference was statistically significant ($X^2$-test = 116.506, p-value =0.001). Mean time for processing using the Parasep system was 6.03 min/sample, the conventional direct wet smear method at 0.3 min/sample. Cost per test, conventional direct wet smear method costing less than the Parasep method at USD 0.74/sample versus USD 1.47/sample. This first report of O. viverrini detection using MPSFC indicates that Parasep concentration test is useful in the routine laboratory, increasing the yield of parasites as compared to direct microscopy, but with greater processing time and cost. Further comparisons between the Parasep concentration test and common methods for O. viverrini detection are required, particularly concerning use in epidemiological surveys.

A Study on the Development and Performance Test of the Non-gravity Fluidized Dryer (무중력 유동층 건조기 개발과 성능평가)

  • Han, J.W.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.665-670
    • /
    • 2001
  • The purpose of this study is to develop a new type dryer, which is to proceed mixing and drying of wet-materials at the same time and drying process is carried out in a closed system. In this drying system, thermal contact occurs, when a fluidized zone is created by paddle mechanism. Accordingly, wet-materials is dried in a short time without any damage. Also wet-materials could be dried uniformly to low moisture contents. It is suitable to dry a small quantity of multi-kind materials. And drying process is carried out in a closed system, so as for environmental pollution dust not to be emitted into the atmosphere. Accordingly, it could be used to dry not only food and chemical materials, but also environmental pollution materials.

  • PDF

Application of the Novel Test Machine, Retention Drainage Analyzer(RDA), for Wet-End Analysis of Papermaking Process (I) (제지공정의 WET-END 분석을 위한 새로운 감압 탈수 초지설비(RDA)의 활용(제1보) - RDA를 활용한 종이 균일성 예측 -)

  • 우이균;류정용;김용환;송봉근;조남석
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.4
    • /
    • pp.1-6
    • /
    • 2002
  • In order to simulate the actual wet-end process in papermachine, RDA, a novel handsheet former, was used and following results were obtained. While the addition of polyelectrolytes gives significant effect on fiber flocculation, increase of stock consistency influenced on the formation of RDA sheets greatly. In particular, the consistency increase from 0.3 % to 0.4% abruptly increased floe size of RDA sheet and it results in severe deterioration of paper strength. Stock consistency, therefore, should be regarded as the most important factor in the formation simulation with RDA and should be controlled as the first sequence of tuning the operating conditions of RDA to simulate correctly the target machine paper's formation.

Repair of Offshore Structures by Underwater Wet Welding Design and Fatigue Assessment

  • Krohn, A.;Petershagen, H.;Pohl, R.;Szelagowski, P.;Lafaye, G
    • Journal of Ship and Ocean Technology
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 1997
  • Under water wet welding is an economically alternative for the repair of offshore structures. In this paper investigations on the fatigue strength of a wet welded pipe structural member have been reported. For the connection a special sleeve patch design has been developed. The joint was fatigue tested. The evaluation of the test was carried out by means of the hot-spot approach with regard to several extrapolation rules of the hot-spot stress. Obtained results have been compared to actual classfication rules and recommendations.

  • PDF