• Title/Summary/Keyword: Wet joint

Search Result 58, Processing Time 0.025 seconds

The Effect of Korean Medical Treatment on 4 Patients with Acute Traumatic Meniscal Tear (급성 외상성 반월연골 파열에 대한 한의학적 치료 증례보고 4례)

  • Heo, Woo Young;Hyun, Min Kyoung;Mo, Min Ju;Kim, Han Ok;Park, Jae Hyeon;Hwang, Ji Hoo
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.197-207
    • /
    • 2015
  • Objectives : The purpose of this study is to report the effect of Korean medical treatment on 4 patients with acute traumatic meniscal tear, presenting severe knee pain and limitation of range of motion of the knee joint. Methods : 4 patients with acute traumatic meniscal tear had been treated with acupuncture, herbal treatment, moxibustion, and wet-cupping therapy. From administration to discharge, we recorded subjective pain by using a visual analogue scale and by measuring the range of motion of the knee joint once per week. Results : The visual analogue scale of knee pain of all 4 cases reduced to 0 after treatment. The range of motion of the knee joint also increased considerably after treatment. Conclusions : In this study, Korean medical treatment may have been effective in reducing knee pain and increasing the range of motion of the knee joint.

Effect of Construction Joint on Leakage Resistance of Gas in Reinforced Concrete Pressure Vessels (철근콘크리트 압력용기에서 시공이음이 가스의 누설저항에 미치는 영향)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • In the nuclear power plant, the steel or polymer liner plates are adopted to prohibit the inner concrete surface from contacting with gas or liquid materials. If there is an accident, the plate may be damaged, and, in this case, concrete shall have the final responsibility to safety requirements. In this paper, an experimental research was carried out to investigate the effects of construction joint and wet and loading conditions on the permeability of concrete. The test results showed that, under a construction joint in the wet condition, leakage of gas pressure has been started from $1kg/cm^2$. However, when there are no construction joints, it is initiated from $2kg/cm^2$. In addition, under the air dried and unloading condition, regardless of with or without the presence of the construction joint, since the gas passage that exist in concrete is constant, leakage has a constant tendency to increase. Finally, under the loading condition, as described in Reference 1, since leakage is inversely proportional to the thickness of the wall, and, considering the wall thickness of the actual plant, it is found that there will not be no problem in the sealing of the gas.

Experimental Study on the Shear Behavior of Ultra High Performance Precast PSC Bridge Joint with Joint Type and Lateral Force (접합 조건 및 횡구속 조건에 따른 초고성능 프리캐스트 PSC 교량 접합부의 전단 거동에 관한 실험적 연구)

  • Lee, Chang-Hong;Kim, Young-Jin;Chin, Won-Jong;Choi, Eun-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5A
    • /
    • pp.379-387
    • /
    • 2011
  • According to the development of ultra-high performance concrete (UHPC), its mechanical performance have been known as superior than normal and/or high performance concrete. However, its construction and structural safety must have studied with revisions and supplements. In this study, tests have been performed on UHPC precast segment joint with different levels of joint types and lateral forces under direct shear. From the results of the experimental tests, it can be concluded that the properties of the referred joints are significant for the resistance of shear behavior, and the increase of lateral force in these joints may suggest as critical lateral stress on that behavior.

A Study on the Development Type of Component Joint Design for Environment Friendly Multi Housing Remodeling-Living Room (I) (공동주택의 친환경 리모델링을 위한 부품접합부 개선방안의 유형화에 관한 연구(I);거실 및 침실을 중심으로)

  • Lim, Seok-Ho;Kim, Soo-Am;Hwang, Eun-Kyoung;Yun, Mae-Han
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.366-369
    • /
    • 2006
  • Multi Housing design has not considered the remodeling even at the beginning of the construction. This severely hindered systematic maintenance, providing fundamental causes of consuming society. In general, in about 20 years when the buildings become too old, they are brought down or removed with a trail of waste left behind. In addition, since the current remodeling or future remodeling type is a general remodeling that leaves only a frame, some question the role of the remodeling as a solution to the reconstruction from economically and environmentally efficient aspects. This study intends to find a solution for long-life span multi-family housing design, promoting sequential remodeling by stating the life cycle of components. Problems were identified by analyzing joints, design and construction of multi-family housing based on the previous researches. Conclusion from characterization of the design plan according to joint parts can be summarized as the following firstly, the problem of the wet was seen in joints between the structure and a finishing materials and ones between separate finishing materials. Secondly, the problem of overlap was frequently seen in joints between the structure and a door/window, ones between a door/window and a finishing materials, and ones between a finishing materials and an electrical/mechanical device.

  • PDF

Development and Shear Performance Evaluation of Vertical Joints between Precast Concrete Walls (PC 벽체 수직접합부의 개발 및 전단성능 평가)

  • Moon, Kyo Young;Kim, Sung Jig;Lee, Kihak;Kim, Yong Nam
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.81-88
    • /
    • 2022
  • The paper introduces an experimental program for the newly developed vertical joints between Precast Concrete (PC) walls to improve their in-plane shear capacity. Compared to the existing vertical joints, two types of vertical joints were developed by increasing the transverse reinforcement ratio and improving frictional force at the joint interface. A total of four specimens including the Reinforced Concrete (RC) wall and PC walls with developed vertical joints were designed and constructed. The constructed specimens were experimentally investigated through monotonic shear tests. The observed damage, load-deformation relationship, strain and strength are investigated and compared with the cases of RC wall specimen. Experimental results indicate that the maximum force and initial stiffness of the PC wall with proposed vertical joints were decreased by comparing with those of RC wall. However, the ultimate displacement increased by up to 217.30% compared to the RC wall specimen. In addition, brittle failure did not occurred and relatively few cracks and damages occurred.

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Crack Repairing Material using in Wet Environment Structure (습윤 환경 구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구)

  • 강효진;우영제;강호경;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.43-48
    • /
    • 2002
  • Since the basement building like the communication hole and etc. is built under the ground where it is pressed by the water, the leakage happens due to the dried-shrinking crack, the sinking crack, the creation of the work-joint of the building and etc. caused by the character of the material and construction way of the reinforced concrete building. Especially, a lot of repair for the leakage cannot help but being taken in temporary way without any noticeable countermeasure. Therefore, this kind of repair is socially criticized many times that this is defective construction even if this costs a lot. The fundamental reason of the above mentioned symptoms can be found in the creation of the work-joint caused by the character of the concrete building, the limitation of the physical performance of the existing water-proof and repair material, the limitation of the construction, the limitation of the physical sustaining performance of the concrete building, the limitation(heat-injury, deterioration) of the constancy of the durability caused by aging and etc. Therefore, in this study, we would like to present the better understanding on the water-proof seal relating to the application at the spot and its test evaluation related data since the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is rising a lot to regulate the water-proof technology and the leakage repair technology in accordance with the growth of the demand on the facility.

  • PDF

Failure Characteristics of Carbon/BMI Sandwich Composite Joint under Pull-out Loading (풀아웃 하중을 받는 카본/BMI 샌드위치 복합재 체결부 파손특성 연구)

  • Lee, Gyeong-Chan;Choi, Young-Ho;Lee, Kowan-Woo;Sim, Jae-Hoon;Jung, Young-In
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.132-137
    • /
    • 2017
  • The purpose of this paper is to investigate failure characteristics of Carbon/BMI-Nomex honeycomb sandwich on design parameters. A total of 6 types sandwich specimens were manufactured according to core height, face thickness and density, and environmental condition were applied to evaluate temperature and humidity effects of one of these specimens. The test results show that the core shear buckling loads was commonly observed in all specimens except for the joint with density of $64kg/m^3$. After core shear buckling, however, the joint carried additional loads over the buckling loads and then finally failed in the upper face and lower face at the same time. In the case of specimen having high stiffness, the maximum failure load was low due to interfacial failure of the upper face and core without initial core shear buckling. The ETW1 and ETW2 conditions, which were carried out to evaluate the environmental condition of the sandwich specimen, show an initial failure mode which was significantly different from RTD condition. Also, the ETW2 condition with increased temperature under the same humidity shows that the core shear buckling load was 18% less than ETW1 condition.

A Study on the effect of the multi-pass SMAW welding on the characteristic of the underwater welding areas (SMAW 수중 다층용접시 용접부 특성에 관한 연구)

  • 최기용;이상율;이보영;이병훈;이상용;박성두
    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.55-62
    • /
    • 1998
  • While excellent joint quality has been obtained using dry chamber underwater welding methods, the size limitations imposed by this process restrict its use for underwater construction work. The wet underwater shielded metal-arc welding eliminates this restriction but suffers from poor weld properties by the 1-pass bead-on-plate welding due to the excessive diffusible hydrogen. On the other hand, in the wet underwater welding, it is well known that the quantity of diffusible hydrogen in multi-pass welded parts reduce to less than that in 1-pass welded parts. Therefore, in this paper, welding experiments are made the 3-pass bead-on-plate welds by using TMCP and normalized steel plates and E4301 and cellulose coated electrode. After that, The amounts of the hydrogen absorbed into the 3-pass welded area were measured according to the JIS Z 3118 specification. The microstructural changes as well as the microhardness distribution after the underwater 3-pass welding were also investigated using Vickers microhardness tester and S.E.M and O.M. The results indicated that the quantity of diffusible hydrogen in 3-pass welded areas was reduced little less than a half of one of that in 1-pass welded areas at the specific welding condition. As a result, the cold cracking of 3-pass welded areas decreased by reduced effect of diffusible hydrogen. In the underwater 3-pass welding, the micrography of cold cracking fracture surface showed mainly the cleavage of hydrogen embrittlement.

  • PDF

Studies on Strength of Netting (3) Joint Strength of Twisted-Jointed Netting (그물감의 강도에 관한 연구 (3) 관통형 그물감의 마디의 강도)

  • KIM Dai An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.4
    • /
    • pp.293-298
    • /
    • 1976
  • 1) The decrease in strength of netting twines at the twisted joint is regarded to be due mainly to tile frictional force between plied yarns, but tile rate of decresae is within $5\%$ in filament twines and 5 to $10\%$ in spun twines. 2) The variation of the twisted joint strength with the angle between the two adjacent bars draws a parabola flaying the minimum value at tile angle of $90^{\circ}$. The minimum value was revealed as about $90\%$ of the strength at the angle of $0^{\circ}$ in wet spun twiness, but regarded to hi negligibly small filament twines. 3) The knot strength is about $30{\pm}5\%$of the twisted joint strength.

  • PDF

The Study on the Dry Floor Tile Unit System used Resin Mat (수지매트를 이용한 바닥타일 건식공법 시스템에 관한 연구)

  • 김성식;임남기;정병훈;정재영;정상진
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.185-190
    • /
    • 2001
  • The purpose of this study is the development of practical Dry floor tile unit method that settle the defect of a wet method and designed for resin mat. With use of PE resin which is confirmed the basic property, it is developed that resin mat, joint-sealing compound with fixed form and space management to Dry floor tile unit method. The result of this study is below. 1) To acquire above the 4kgf/$\textrm{cm}^2$ - construction specification criterion, the bonding space that between resin mat and tile has to occupy the 50% of resin mat module space(10,000$\textrm{cm}^2$). 2) Criteria of bonding part plane is below. simpleness of metal form. productivity, uniform quality after injection molding cooling, easy cutting for remain space management, adhesive property, construction ability, transformation of a severed piece under pressure and so on. 3) To get the shape that could protect the interfacial breakdown, it is designed that resin mat and tile are unified after the bond input. 4) Adapted joint-sealing compound is the material of urethane kinds wedge form. Resin mat has the water passageway that could drain the water. 5) To manage the severed piece of tile, the resin mat is likely to divide the half and the quarter and the plastic drainage is developed in the severed piece.

  • PDF