• Title/Summary/Keyword: Wet Type Floor Heating System

Search Result 3, Processing Time 0.021 seconds

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

An Experimental Study on Structural Safety Assesment of Wet Type Floor Heating System with Insulation (완충재 적용에 따른 습식온돌의 구조안전성 평가를 위한 실험연구)

  • Ahn, Jae-Won;Jun, Myoung-Hoon;Lee, Bum-Sik;Lee, Do-Heun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.287-290
    • /
    • 2005
  • Housing is demanded to convert simple dwelling space into delightful one by improving of standard of living by economic development It is interested in the impact noise of the apartment housing that is revised to housing construction criteria at 29 March 2005 and then regulated the level of floor impact noise by the rule. The plan, which is actively investigated by counterplan for the reduction of impact noise, is application of sound insulation. In generally, first target by using insulation is the reduction of floor thermal transmittance in floor heating system of apartment housing. It is recently proposed soft materials that reduce the impact noise. However, it is a fact that the application of soft sound insulation includes some problem about structural performance. In this study, we made wet-heating specimen with various sound insulations, and carried out structralexperiment for evaluating the structural safety of it.

  • PDF