• Title/Summary/Keyword: Welfare medical device center

Search Result 15, Processing Time 0.019 seconds

Research on Safety and Quality Regulatory Policy for Assistive Products (보조기기 안전·품질관리 방안 연구)

  • Kim, Hye-Won;Kim, Dong-A;Seo, Won-San;Kim, Jang-Hwan;Ko, Myeong Han;Son, Byung-Chang;Yi, JinBok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.805-813
    • /
    • 2018
  • The research was conducted with the purpose of providing effective safety and quality control system for assistive products for handicapped those are used extensively. Assistive products couldn't be classified independently due to collision with the act of medical device and lack in legal basis. The issues about safety and quality have been solved by other legal frames on a case by case basis. We couldn't find any abroad case of independent safety and quality control policy. For the practical solution, this article suggested hybrid classification system mixed with existing policies. Each classified branches are allocated to the appropriate policy of safety and quality control so those are ease of understanding and prospect. And also a delicacy process was suggested not to leave off any assistive products. Through these suggests of the improvement it is expected that blind areas of safety and quality control for assistive products for handicapped could be solved and identity of assistive products could be established to provide product safety for handicapped and boost relevant industries.

Dementia Response Technology Development Strategy through PEST-SWOT Analysis

  • Yu, Tae Gyu
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.185-192
    • /
    • 2020
  • The number of dementia patients in Korea is expected to increase to 3.30 million in 2050, and the cost of dementia management will increase sharply to KRW 106.5 trillion of GDP. In August 2017, the Moon Jae-in government announced the 'Dementia National Responsibility System' through a five-year plan for government operation and expanded the Dementia Peace Center nationwide. However, for this, strategic dementia-related technology development strategies should be established and given the role of government and the role of the private sector. Therefore, in order to derive the corresponding strategy, this study developed the government's 'dementia' response technology development strategy through the situation analysis from the political, economic, social, and technological perspective and the environmental (PEST) analysis of the strengths, weaknesses, opportunities, and threats (SWOT). As a result, the direction of technology development in the dementia-related medical device market is expected to become a trend of developing dementia self-measurement by developing low-cost and high-efficiency diagnostic technology products. It has been shown that the development of various products for consumers should begin. As a result, the dementia market approach strategy should be premised, the related technical support and legal restrictions should be minimized, and the education of related experts should be strengthened to solve the government's development of dementia technology and the social problems of dementia. In addition, by developing joint projects with major companies around the world and actively participating in the technology platform, it is important to naturally build up skills accumulation for the development of dementia technology and competence skills of dementia technology experts in the long term.

A Survey on the Present Situation and Satisfaction in Assistive Technology of Person with Physical Disabilities (지체장애인의 보조공학 이용 실태 및 만족도 조사)

  • Lee, Chun-Yeop;Kim, Eun-Joo;Noh, Dong-Hee;Moon, Seo-Jin;Park, Sung-Ho;Chae, Gang-Seok;Chang, Moon-young
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.3 no.1
    • /
    • pp.21-31
    • /
    • 2013
  • Objective : This study was aimed to survey the present situation and satisfaction in assistive technology of the physically disabled person. Method : 110 patients, being diagnosed with spinal cord injury and stroke, were chosen and structured interview was carried out using by a questionnaire. Result : The followings are the results of this study. First, spinal cord injury(76.2%) and stroke(72.5%) patients used the most wheelchair and mobility devices in assistive technology device. Second, they were satisfied in effectiveness of assistive technology device. Third, spinal cord injury(39.4%) patients used the most repair service in assistive technology service. Fourth, stroke(28.2%) patients used the most application and training service. Fifth, they were satisfied in professionality while were dissatisfied in service delivery program. Conclusion : The results of this study would contribute to better assistive technology for the physically disabled person.

  • PDF

Analysis on the Assist Characteristics for the Knee Extension Motion of Lower Limb Orthosis Using Muscular Stiffness Force Feedback (근육 강성도 힘 피드백을 이용한 하지 보조기의 무릎 신전 운동 보조 특성 분석)

  • Kim, K.;Kang, S.R.;Jeong, G.Y.;Joo, S.J.;Kim, N.G.;Kwon, T.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.217-226
    • /
    • 2010
  • The lower limb orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of muscular activities of lower limbs was developed in this study. Compared to other knee extension assistive devices being developed by other researchers, our device is designed especially for the elderly people and intended only for slight assistance so that the subjects can keep their muscular strength. For the effectiveness of system, muscular activities of major muscles in lower limbs during sit-to-stand (STS) and squat motion were measured and analyzed. Subjects were performed the STS and squat motion with and without lower limb orthosis. We made comparison muscular activities between with and without lower limb orthosis. Lower limb orthosis was controlled using muscular stiffness force feedback that is controlled by muscular activities of the measured muscle from force sensor. For analysis of muscular activities, electromyography of the subjects was measured during STS and squat motion, and these were measured using MP 150(BIOPAC Systems, Inc.). Muscles of interest were rectus femoris(RF), vastus lateralis(VL), vastus medialis(VM) and vastus intermedius(VI) muscles in lower limbs of the right side. A biodex dynamometer was used to measure the maximal concentric isokinetic strength of the knee extensors of wearing and not wearing orthosis on right side. The test were performed using the concentric isokinetic mode of test with the velocity set at 60°/s for muscles around the knee joints. The experimental result showed that muscular activities in lower limbs wearing orthosis using muscular stiffness force of a vastus medialis muscle was reduced and knee extension torque of an knee joint wearing lower limb orthosis was increased. With this, we confirmed the effectiveness of the developed lower limb orthosis.

Evaluation of Albumin Creatinine Ratio as an Early Urinary Biomarker for Chronic Kidney Disease in Dogs

  • Hyun-Min Kang;Heyong-Seok Kim;Min-Hee Kang;Jong-Won Kim;Dong-Jae Kang;Woong-Bin Ro;Doo-Won Song;Ga-Won Lee;Hee-Myung Park;Hwi-Yool Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.399-407
    • /
    • 2023
  • Chronic kidney disease (CKD) occurs in more than 15% of the dogs over 10 years of age and causes irreversible renal function deterioration. Therefore, it is important to diagnose CKD early and treat the disease properly. The purpose of this study aimed to to evaluate the clinical utility of urine albumin/creatinine ratio (ACR) using POC (point-of-care) device as an early detection urinary biomarker in CKD dogs and to confirm the correlation between ACR and other known CKD biomarkers. Urine and serum samples were obtained from 50 healthy dogs and 50 dogs with CKD. Serum blood urea nitrogen (BUN), creatinine, and symmetric dimethylarginine (SDMA) concentrations, and urine protein creatinine ratio (UPC) were measured. Urine specific gravity (USG) was evaluated using refractometer, and ACR was measured using an i-SENS A1Care analyzer. The ACR values of dogs with CKD were significantly different from those of healthy dogs (p < 0.001), as with other renal biomarkers. ACR showed significant differences between healthy dogs and dogs with CKD at every IRIS stage (p < 0.005), whereas no significant differences were observed between dogs with CKD IRIS stage I and healthy dogs with UPC. There are significant positive correlation between ACR and BUN (r = 0.611, p < 0.001), creatinine (r = 0.788, p < 0.001), SDMA (r = 0.747, p < 0.001), and UPC (r = 0.784, p < 0.001), and significant negative correlation between ACR and USG (r = -0.700, p < 0.001). In receiver operator characteristic curve analysis, the area under the curve (AUC) was 0.982 (95% CI 0.963-1.000, p < 0.001), with an optimal cut-off value of 64.20 mg/g (94% sensitivity and 94% specificity). Thus, ACR is a useful urinary biomarker for the early diagnosis of proteinuria in CKD and combined use of ACR and other renal biomarkers may be helpful for early diagnosis and prevention of CKD in dogs.