• 제목/요약/키워드: Weight calibration

검색결과 169건 처리시간 0.022초

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권4호
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.

휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발 (Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users)

  • 장경배;이경완;구도훈
    • 대한임베디드공학회논문지
    • /
    • 제8권1호
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.

Ensemble Model Output Statistics를 이용한 평창지역 다중 모델 앙상블 결합 및 보정 (A Combination and Calibration of Multi-Model Ensemble of PyeongChang Area Using Ensemble Model Output Statistics)

  • 황유선;김찬수
    • 대기
    • /
    • 제28권3호
    • /
    • pp.247-261
    • /
    • 2018
  • The objective of this paper is to compare probabilistic temperature forecasts from different regional and global ensemble prediction systems over PyeongChang area. A statistical post-processing method is used to take into account combination and calibration of forecasts from different numerical prediction systems, laying greater weight on ensemble model that exhibits the best performance. Observations for temperature were obtained from the 30 stations in PyeongChang and three different ensemble forecasts derived from the European Centre for Medium-Range Weather Forecasts, Ensemble Prediction System for Global and Limited Area Ensemble Prediction System that were obtained between 1 May 2014 and 18 March 2017. Prior to applying to the post-processing methods, reliability analysis was conducted to identify the statistical consistency of ensemble forecasts and corresponding observations. Then, ensemble model output statistics and bias-corrected methods were applied to each raw ensemble model and then proposed weighted combination of ensembles. The results showed that the proposed methods provide improved performances than raw ensemble mean. In particular, multi-model forecast based on ensemble model output statistics was superior to the bias-corrected forecast in terms of deterministic prediction.

한우의 3차원 영상에서 결정된 몸통 체적을 이용한 체중 추정 (Estimation of Body Weight Using Body Volume Determined from Three-Dimensional Images for Korean Cattle)

  • 장동화;김철수;김용현
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.393-400
    • /
    • 2021
  • 가축의 체중은 사료 요구량과 영양 상태를 평가하는 데 필요한 주요 지표에 해당한다. 본 연구는 한우의 3-D 영상으로부터 몸통 체적을 산출한 후 체중을 추정하고자 시도되었다. 한우의 3-D 영상 획득에 640×480 픽셀의 해상도, 44fps의 프레임속도 및 47°(H)×37°(V)의 화각을 갖는 TOF 카메라가 사용되었다. 획득된 3-D 영상에서 배경과 몸통 분리, 이상치 제거 등의 전처리 과정을 거쳐서 몸통에 대한 격자 영상을 얻었다. 또한 각각의 격자에 깊이 정보를 적용한 수치적분으로 몸통 체적을 결정하였다. Calibration dataset에서 체중과 몸통체적의 선형회귀에 대한 결정계수는 0.8725로 나타났다. 한편 몸통 체적에 월령을 설명 변수로 추가한 체중 추정의 중회귀 모형에서 결정계수는 0.9083으로 나타났다. Validation dataset에서 중회귀 모형을 이용한 체중 추정의 MAPE와 RMSE는 각각 8.2%, 24.5kg으로 나타났다. 결과적으로 체중 추정을 위한 회귀 모형의 성능이 개선되고, 체중 추정에 소요되는 노력이 절감됨을 고려한다면 3-D 영상에서 결정된 몸통 체적이 한우의 체중 추정에 유효한 변수로 사용될 것이다.

추교환식 실하중 힘표준기의 개발 (Development of a Deadweight Force Standard Machine with Weight Change Mechanism)

  • 김갑순;송후근;강대임;이정태;박연규
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.203-212
    • /
    • 1999
  • This paper describes a deadweight force standard machine with the weight change mechanism which can be used as a primary force standards at a national metrology institute. Since commercial deadweight force machine can generate forces by hanging weights to the weight supporter serially, force steps from deadweight force measuring devices of each having different capacity. In order to increase the force steps, we have specially designed a weight mechanism in which the machine can select the necessary weights and generate the load by hanging the selected weights to the weight supporter. The machine can generate 속 force of the range of 2 kN to 110 kN with force step of 1 kN. All weights have been accurately compensated and calibrated by a mass comparator and its standard uncertainty is less than 2.2 ${\times}\;10^{-6}$. The relative expanded uncertainty of the machine is 1.3 ${\times}\;10^{-5}$.

  • PDF

An Automatic Weight Measurement of Rope Using Computer Vision

  • Joo, Ki-See
    • 한국정보통신학회논문지
    • /
    • 제2권1호
    • /
    • pp.141-146
    • /
    • 1998
  • Recently, the computer vision such as part measurement, and product inspection is very popular to achieve the factory automation since the labor cost is dramatically increasing. In this paper, the diameter and the length of rope are measured by CCD camera which is orthogonally mounted on the ceiling. Two parameters which are the diameter and the length of rope are used to measure the weight of rope. If the weight of rope is reached to predetermined weight, the information is transmitted to PLC(programmable logic control) to cut the rope on the wheel. The cutting machine cuts the rope according to the information obtained from the CCD camera. To measure the diameter and length of rope on real time, the searching space for image segmentation is restricted the predetermined area according to the camera calibration position. Finally, to estimate the weight of rope, the knowledge base system which depends on the diameter, the length of rope, and weight relation between these information are constructed according to diameters of rope. This method contributes to achieve the factory automation, and reduce the production cost since the operators are unnecessary to measure the weight of rope by try-and-error method.

  • PDF

EVALUATION OF NIRS FOR ASSESSING PHYSICAL AND CHEMICAL CHARACTERISTICS OF LINEN WEFT YARN

  • Sharma, Hss;Kernaghan, K.;Whiteside, L.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1091-1091
    • /
    • 2001
  • Previous reports have shown that Near Infrared Spectroscopy (NIRS) can be used to assess physical and chemical properties of flax fibre and fabric quality. Currently, spinners assess yarn quality mainly based on strength and regularity measurements. There two key characteristics are influenced by quality of raw fibres used, especially the degree of rotting and strength. The aim of this investigation was to evaluate the use of NIRS for assessing quality of weft grade yarn available on the commercial market. In order to develop the NIR calibrations, a range of samples representing poor, medium and good quality weft yarn samples was included in the calibration and validation sample sets. The samples were analysed for physical and chemical parameters including caustic weight loss, fibre fractions, lipid, ash and minerals. A detailed protocol for assessing yarn quality has been developed to maximize the accuracy of the reflectance spectra. The development of partial least squares regression models and validation of the calibration equations using blind samples will be presented and discussed.

  • PDF

Comparison of Vinyl Acetate Contents of Poly(Ethylene-co-Vinyl Acetate) Analyzed by IR, NMR, and TGA

  • Kim, Eunha;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • 제50권1호
    • /
    • pp.18-23
    • /
    • 2015
  • Vinyl acetate (VA) contents of poly(ethylene-co-vinyl acetate) (EVA) analyzed by infrared spectroscopy (IR), nuclear magnetic spectroscopy (NMR), and thermogravimetric analysis (TGA) were compared. Four grade EVAs supplied by Aldrich Co. and four grade EVAs manufactured by DuPont Co. were used. For IR analysis, VA contents were determined using calibration curve (absorbance ratio of $1739cm^{-1}/2922cm^{-1}$ or $609cm^{-1}/1464cm^{-1}$) of reference EVAs. Correlation coefficients of the calibration curves were not sufficiently high ($r^2{\leq}0.96$). For NMR analysis, VA contents were determined using peaks of $CH_3$, $CH_2$, and CH. VA contents determined by NMR analysis were less than those marked by suppliers more than 10%. For TGA, VA contents were determined using weight loss through deacetylation. VA contents determined by TGA were slightly different with those marked by suppliers. Difference in the VA contents determined by different analytical methods was discussed, and difference in the analytical results according to the EVA suppliers was also examined.

그물코의 길이와 콧수의 변화에 따른 모노필라멘트 자망 그물감의 중량 계산 (Calculation of weight on netting with the changes of size and number of mesh for monofilament gill net fishing gear)

  • 박성욱
    • 수산해양기술연구
    • /
    • 제48권4호
    • /
    • pp.301-309
    • /
    • 2012
  • A net-assembling company for gill net fishing gears makes a design based on the size of nets provided and determines floats, types of weights, and numbers. In addition, through the accurate examination of net weights in the process of fishing gear designing, it can prevent an excessive use of designing costs. The weight of twine can be easily calculated by its thickness differences, but the weight of netting has errors to be calibrated since the weight of netting is not changing exponentially with the changes of number and size of meshes. This study aims to suggest and empirically analyze the methods for estimating the weights of netting in accordance with the changes of number, size and thickness of meshes for a sound management of netting and net-assembling companies. Results indicated that the method using the knots and legs of netting was not practically usable because the errors were increased as the number of mesh increased. However, the method using netting area shown its usage potentiality with the calibration of the increasing ratio of mesh numbers.

Study of Equivalent Retention among Different Polymer-Solvent Systems is Thermal Field-Flow Fractionation

  • 김원숙;박영훈;문명희;유유경;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권8호
    • /
    • pp.868-874
    • /
    • 1998
  • An equivalent retention has been experimentally observed in thermal field-flow fractionation (ThFFF) for different polymer-solvent systems. It is shown that iso-retention between two sets of polymer-solvent systems can be obtained by adjusting the temperature difference (ΔT) according to the difference in the ratio of ordinary diffusion coefficient to thermal diffusion coefficient. This method uses a compensation of field strength (ΔT) in ThFFF at a fixed condition of cold wall temperature. It is applied for the calculation of molecular weight of polymers based on a calibration run of different standards obtained at an adjusted AT. The polymer standards used in this study are polystyrene (PS), polymethylmethacrylate (PMMA), and polytetrahydrofuran (PTHF). Three carrier solvents, tetrahydrofuran (THF), methylethylketone (MEK) and ethylacetate (ETAc) were employed. Though the accuracy in the calculation of molecular weight is dependent on the difference in the slope of log λ vs. log M which is related to Mark-Houwink constant a, it shows reasonable agreement within about 6% of relative error in molecular weight calculation for the polymer-solvent systems having similar a value.