• Title/Summary/Keyword: Weight Measurement

Search Result 1,900, Processing Time 0.03 seconds

Evaluation of Postural Load during Liquid Weight Measurement Process Using Ratio of Exposure Time

  • Lee, Sung-Koon;Park, Peom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.445-453
    • /
    • 2012
  • The aim of this paper was to prove that if the risk level in combined tasks was improved through evaluation of postural load of liquid weight measurement process, the workload level and ratio of exposure time would be changed, and the time of process would be seen concurrently. Background: According to results of epidemiological studies conducted by Korea Occupational Safety & Health Agency, 122 musculoskeletal disorders occurred during 1992 to 2008, in which manufacturing industry covers 96(78.7%) of total. However, this is an insufficient level and only occupies 39% based on the South Korea's manufacturing standard industrial classification(246 industries). Method: Firstly, the number of batches weighed on one day(460min) was investigated based on the work performed and Weight measured weekly. VCR recording was taken based on the level of liquid ingredients prescribed for 1batch using the Camcorder. After dividing a 356 sec video into 1 sec using the screen capture function in Gom player, the job classification was performed by analyzing the change of working postures, which revealed 148 working postures. Time measurement was decided by time of the postures was being maintained. Then, the REBA analysis was performed for the working postures. The ratio of Exposure time was calculated based on the measurement time and REBA Score. In addition, the recommendations were designed and implementation was carried out for the working postures with REBA Score higher than 3. Finally, after the intervention, REBA measurement, time measurement, and ratio of exposure time were calculated for the comparison of works before and after improvement. Results: The number of work elements was decreased by 30.4% from 148 to 103 after improvement. The results of time measurement showed that the time was reduced by 46.3% from 356 sec to 191 sec. And the ratio of exposure time was also improved by 52.1% from 0% to 52.1% after improvement. Conclusion: The reduction of time was found to improve the productivity of management. Furthermore, because the reduction of ratio of exposure time and the improvement of workload level are the improvement of discomfort, it would contribute to the improvement of the worker's psychological working posture. Application: These results would contribute to musculoskeletal disease prevention and management performance. Further studies for other industries would be needed based on this case study.

Statistical Estimate and Prediction Values with Reference to Chronological Change of Body Height and Weight in Korean Youth (한국인 청소년 신장과 체중의 시대적 변천에 따른 통계학적 추정치에 관한 연구)

  • 강동석;성웅현;윤태영;최중명;박순영
    • Korean Journal of Health Education and Promotion
    • /
    • v.13 no.2
    • /
    • pp.130-166
    • /
    • 1996
  • As compared with body height and body weight by ages and sexes, by means of the data reported under other researchers from 1967 to 1994 for 33 years, this study obtained the estimate value of body height and body weight by ages and sexes for the same period, and figured out prediction value of body height and body weight in the ages of between 6 and 14 from 1995 to 2000. These surveys and measurements took for one year from October 1st 1994 to September 30th. As shown in the 〈Table 1〉, in order to calculate the establishment, estimate value and prediction value of the chronological regression model of body height and body weight, by well-grounded 17 representative research papers, this research statistically tested propriety of liner regression model by the residual analysis in advance of being reconciled to simple liner regression model by the autonomous variable-year and the subordinate variable-body weight and measured prediction value, theoretical value from 1962 to 1994 by means of 2nd or 3rd polynomial regression model, with this redult did prediction value from 1995 to 2000. 1. Chronological Change of Body Height and Body Weight The analysis result from regression model of the chronological body height and body weight for the aged 6 - 16 in both sexes ranging from 1962 to 1994, corned from the 〈Table 2-20〉. On the one hand, the measurement value of respective researchers had a bit changes by ages with age growing, but the other hand, theoretical value, prediction value showed the regular increase by the stages and all values indicated a straight line on growth and development with age growing. That is, in case of the aged 6, males had 109.93cm in 1962 and females 108.93cm, but we found the increase that males had 1I8.0cm, females 1I3.9cm. In theoretical value, prediction value, males showed the increase from 109.88cm to 1I7.89cm and females from 109.27cm to 1I5.64cm respectively. There was the same inclination toward all ages. 2. Comparision to Measurement Value and Prediction Value of Body Height and Body Weight in 1994 As shown in the 〈Table 21〉, in case of body height, measurement value and prediction value of body height and body weight by ages and sexes almost showed the similiar inclination and poor grade, in case of body weight, prediction value in males had a bit low value by all ages, and prediction value in females had a high value in adolescence, to the contrary, a low value in adult. 3. Prediction Value of Body Height and Body Weight from 1995 to 2000 This research showed that body height and body weight remarkably increased in adolescence but slowly in adult. This study represented that Korean physique was on the increase and must be measured continually hereafter.

  • PDF

The effect of the self-measurement frequency levels on SmartCare obesity management (스마트케어 비만관리에서 자가 측정 빈도 수준의 효과)

  • Lee, Chang-Hee;Chang, Byeong-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1972-1980
    • /
    • 2015
  • This study's purpose was to analyze the effect of the SmartCare obesity management pilot project, which was conducted between 09 March 2011 and 03 April 2013 in Korea (South). Of 212 subjects who were enrolled in the study, the final analysis was conducted with 147 subjects who completed their weight self-measurements and SmartCare services until the end of a 6-month service period. The self-measurement group for evaluation was classified into 3 groups (Low, Middle, and High) by evenly dividing the monthly average frequency of measurement for 6 months and the evaluation indices were weight, and BMI (Body Mass Index) transmitted from the SmartCare System. The monthly average weight and BMI were decreased more in the High Group than the Middle Group and Low Group (M5: High>Middle>Low), and they are showing statistically significant differences between groups (p< 0.05). In conclusion, analysis of the weight and BMI improvement effect showed a greater improvement effect when the self-measurement frequency level was higher.

Thirteen Weeks Repeated-dose Toxicity Study on Aconitum ciliare Decaisne Pharmacopuncture Solution in Mice (초오 약침액의 13주 반복 시술 독성에 관한 연구)

  • Lim, Sung Chul;Kim, Jae Soo;Lee, Bong Hyo;Lee, Hyun Jong;Lee, Hyun;Lee, Yun Kyu
    • Korean Journal of Acupuncture
    • /
    • v.35 no.3
    • /
    • pp.139-148
    • /
    • 2018
  • Objectives : This study was performed to examine the toxicity on the long term procedure of Aconitum ciliare Decaisne pharmacopuncture(ADP) solution. Methods : To evaluate the long term toxicity of 3 different repeated doses, 60, 150, and 300 mg/kg/day for 13 weeks were injected into BALB/c mice, respectively. The ADP solution was injected into near ST36 of the right leg and normal saline of the same volume was used for the vehicle control group. To evaluate the toxicity of 60, 150, and 300 mg/kg of repeated doses for 13 weeks, toxic symptoms, weight measurement, hematological test, blood biochemical test, visual examination and weight measurement of major organs, and histopathological test were conducted. Results : No significant changes in toxic symptoms, weight measurement, hematological test, blood biochemical test, visual examination and weight measurement of major organs, and histopathological test were observed in different doses of ADP solution treated groups compared to vehicle control group. Conclusions : As a result, repeated dose at a concentration of 300 mg/kg or less is considered to be not harmful for clinical treatment.

Determination of Molecular Weight and Molecular Weight Distribution of Polypropylene Using Rheological Properties (유변학적 물성을 이용한 폴리프로필렌의 분자량과 분자량 분포를 결정하는 방법)

  • Lee, Young Sil;Yoon, Kwan Han
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.735-743
    • /
    • 2014
  • The rheological measurement of polypropylene (PP) has been performed using a rheometer, an intrinsic viscometer, and an MI machine to predict the molecular weight and the molecular weight distribution. Also, GPC has been used for the determination of the molecular structure. The distribution broadness parameter using modified Carreau model has been used to make the correlation between the rheological parameter and the molecular structure instead of the rheological PI (polydispersity index) which is determined from the cross of modulus from the dynamic oscillatory measurement. Even though the rheological PI is useful to determine the molecular weight distribution of the PP using controlled rheology, which has narrow and uniform molecular weight distribution, but not suitable to determine the molecular weight distribution of the PP made from direct polymerization which has broad and various molecular weight distribution. However the distribution broadness parameter which determined from the index of the shear thinning of the PP melt well predicts the molecular weight distribution of PP.

Development of weight prediction 2D image technology using the surface shape characteristics of strawberry cultivars

  • Yoo, Hyeonchae;Lim, Jongguk;Kim, Giyoung;Kim, Moon Sung;Kang, Jungsook;Seo, Youngwook;Lee, Ah-yeong;Cho, Byoung-Kwan;Hong, Soon-Jung;Mo, Changyeun
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.753-767
    • /
    • 2020
  • The commercial value of strawberries is affected by various factors such as their shape, size and color. Among them, size determined by weight is one of the main factors determining the quality grade of strawberries. In this study, image technology was developed to predict the weight of strawberries using the shape characteristics of strawberry cultivars. For realtime weight measurements of strawberries in transport, an image measurement system was developed for weight prediction with a charge coupled device (CCD) color camera and a conveyor belt. A strawberry weight prediction algorithm was developed for three cultivars, Maehyang, Sulhyang, and Ssanta, using the number of pixels in the pulp portion that measured the strawberry weight. The discrimination accuracy (R2) of the weight prediction models of the Maeyang, Sulhyang and Santa cultivars was 0.9531, 0.951 and 0.9432, respectively. The discriminative accuracy (R2) and measurement error (RMSE) of the integrated weight prediction model of the three cultivars were 0.958 and 1.454 g, respectively. These results show that the 2D imaging technology considering the shape characteristics of strawberries has the potential to predict the weight of strawberries.

Visual Precise Measurement of Pile Rebound and Penetration Movement Using a High-Speed Line-Scan Camera

  • Lim, Mee-Seub;You, Bum-Jae;Oh, Sang-Rok;Han, Song-Soo;Lee, Sang-Hun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.341-346
    • /
    • 2002
  • When a construction company builds a high structure. many piles should be driven into the ground by a hammer whose weight is 7,000 kg in order to make the ground under the structure safe and strong. So. it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously. Especially- by adopting a line-scan CCD camera whose line rate is 20 ㎑. the measurement performance of dynamic characteristics of the pile at impact instant is improved dramatically.

Study on terminal shape and pressure for contact type Ic measurement of long Bi-2223 tape (Bi-2223 초전도 테이프의 접촉식 Ic 측정을 위한 단자 형상 및 압력 조사)

  • Ha, D.W.;Yang, J.S.;Ha, H.S.;Oh, S.S.;Kwon, Y.K.;Ryu, K.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.25-28
    • /
    • 2002
  • Contact type Ic measurement system is needed to measure Ic continuously for long Bi-2223 tapes. Voltage and current terminals were designed several shapes for 4-probe method Ic measurement. Voltage terminals were made with brass and current terminals were made with Cu. We used 2 kinds of Bi-2223 tapes with different strength. When we measured Ic of Bi-2223 tape with Ag-Mg sheath, The proper weight was 0.3 kg and sharp pin type was better. according to voltage terminal shape and load. In case of Bi-2223 tape with Ag-Mn sheath, the proper terminal weight was 4 kg and sharp pin type was bad. It was possible to make continuous contact type Ic measurement system because We could get proper data - terminal shapes and loads - through these experiments.

  • PDF

Accuracy evaluation of diagnostic parameters estimated by uroflowmetry technique measuring hydraulic pressure (수압측정 방식의 요류검사 진단매개변수의 정확도 평가)

  • Kim, Kyung-Ah;Choi, Seong-Su;Kim, Sung-Sik;Kim, Kun-Jin;Park, Kyung-Soon;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.413-418
    • /
    • 2007
  • Uroflowmetry is of great convenience to diagnose benign prostate hypertrophy common in aged men. The urinary flow rate is obtained by weight measurement using load cell, however, sensitive to impact noise. An alternative technique was recently proposed to measure hydraulic pressure instead of weight and demonstrated to introduce significantly reduced noise. In this paper, we described the measured diagnostic parameters between the weight and pressure measuring techniques in 10 normal men. The weight and pressure signals were simultaneously acquired during urination, converted into urine volumes, then differentiated to obtain flow rate signals, which showed very similar waveforms. Diagnostic parameters evaluated by pressure measuring technique were well correlated with the standard weight measuring technique (correlation coefficient > 0.99). Therefore, the new uroflowmetry based on hydraulic pressure measurement can provide accurate diagnostic parameters, which would be clinically valid.

The Analysis on Relation between Hamstring Length and Static Uprighting Balance (넙다리 뒤근육의 길이와 정적 기립균형과의 상관성 분석)

  • Nam, Kun-Woo
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate hamstring length during static uprighting position using weight distribution ratio. Methods: Ninety-six volunteers(56 males) were participated. The active knee extension test(AKE) was measured 3 times on both legs. The mean score of AKE was obtained. Then, the measurement of weight distribution ratio was observed 3 times on both legs, and its mean value was also calculated. Subjects were divided four groups based on their hamstring length measurement; both hamstring shortening group, left hamstring shortening group, right hamstring shortening group and normal hamstring length group. One-way ANOVA was employed to analyse collected data. Pearson's correlation was also hired to see any relationship between the hamstring length and the weight distribution. Results: In anterior/left area and posterior/right area, both hamstring shortening group left hamstring shortening group were superior to right hamstring shortening group and normal hamstring length group. Significant difference was existed statistically(p<.05) between groups. The correlation analysis between hamstring length and weight distribution ratio has not been shown any significant findings(Pant/post=0.733, Plt/rt=0.135). Conclusion: The results of the study may be applied to therapeutic management in posture and movement skill in musculoskeletal physical therapy.

  • PDF