• Title/Summary/Keyword: Wearing effect

Search Result 545, Processing Time 0.026 seconds

A Comparative Study on the Effects of Wearing Reverse Geometry Lenses by Degrees of Myopia (근시정도에 따른 역기하렌즈 착용효과에 관한 비교 연구)

  • Yoon, Min-Hwa;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.265-272
    • /
    • 2012
  • Purpose: To compare the results on myopia correction with reverse geometry lenses, effects of wearing reverse geometry lenses were evaluated for the children with low-level and high-level myopia. Methods: The research investigated the corrective effects of having worn reverse geometry lenses for one week, one month, three months and six months on a total of thirty-six persons (sixty-two eyes) between the ages of seven and fifteen, divided into three groups by the degree of their myopia; nineteen eyes(Group One) with myopia of -2.00 D and under, twenty-eight eyes(Group Two) with myopia between -2.25 D and -4 D, and fifteen eyes(Group Three) with myopia of -4.25 D and above; as shown by changes in uncorrected vision and the degree of refraction in the corneal topography, and tested for statistical similarity among the pursued results. Results: After wearing reverse geometry lenses, Group One showed an improvement in vision of 0.5, from 0.45 to 0.95, after one week, and improvements to 0.91 after one month and 1.02 after three months but, after six months, the group's vision regressed to 0.95. Group Two showed an improvement in vision of 0.43, from 0.34 to 0.77, after one week of wearing and to 0.91 after one month, to 0.97 after three months and this was statistically maintained through the remainder of six months. Group Three showed an improvement in vision of 0.55, from 0.15 to 0.7, after wearing for one week, to 0.87 after one month and to 0.91 after three months but saw a regression to 0.86 after six months. The average Sim K (simulated keratometry reading) value for Group One started from $42.84{\pm}1.17D$ and decreased to $41.48{\pm}0.98D$ after one week of wearing and continued declining through three months before increasing during the remainder of six months. Group Two began from $42.91{\pm}1.57D$ and recorded $41.78{\pm}1.58 D$ after one week, continuing the decline through three months before increasing during the remainder of six months. Group Three began at $42.64{\pm}1.64D$ and showed its Sim K value decrease to $40.77{\pm}1.20D$ after one week of wearing, increase after one month and decrease after three months and continue the decline through the remainder of six months. Conclusions: From the results of this study, wearing reverse geometry lenses had myopia-correcting effects after one week of wearing. Although there were variations in the time for such effect to take place but myopia-correcting effects were evident in all test groups.

The Effect of Posture Holding Band on Muscle Activity of Quadriceps Femoris and Weight Distribution during Squat Exercise (자세유지밴드가 스쿼트 운동 시 넙다리네갈래근의 근활성도와 체중분포에 미치는 영향)

  • Chung-Yoo Kim;Won-Sik Bae;Sung-Ha Yu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.91-98
    • /
    • 2023
  • Purpose : The purpose of this study was to investigate the effect of the posture holding band on muscle activity of the rectus femoris, medial vastus, and vastus lateralis muscles and weight distribution during squat exercise. Methods : This study was conducted with 30 healthy adult men and women in their 20s, and all subjects were randomly assigned to the experimental group and the control group. Squat exercise was performed for 6 weeks. The experimental group received squat exercise while wearing a posture holding band, and the control group applied without wearing a posture holding band. Muscle activity of the quadriceps femoris (rectus femoris, vastus medialis, and vastus lateralis) and weight distribution (knee flexion 0 °, 30 °, 60 °, and 90 °) was measured. Results : According to the results of this study, all three muscles showed a main effect on time and group, and a significant interaction was shown only in the vastus lateralis. In addition, the value of the weight distribution difference according to the knee flexion angle did not show a main effect according to time and group at 30 ° of knee flexion, but showed an interaction. Conclusion : It was confirmed that the application of the posture holding band during squat exercise increased the muscle activity of the quadriceps muscle, and showed greater changes in the vastus lateralis muscle. In addition, it was confirmed that the difference in weight distribution was reduced in the knee flexion, and in particular, a greater change was shown in reducing the difference in weight distribution in the knee flexion of 30 °. Therefore, it is considered that the effect of the exercise can be further enhanced if the unnecessary movement of the trunk is controlled by using equipment such as a posture holding band during squat exercise.

The Study on Improvement of Reading Ability for Dyslexia Wearing Color filter lens (ChromaGenTM Lens) (칼라필터 렌즈(ChromaGenTM)를 이용한 읽기능력 향상에 대한 임상연구)

  • Lee, Seok-Ju;Park, Ji-Hoon;Lee, So-Hee;Whang, Kwang-Ha;Ryu, Guen-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.65-74
    • /
    • 2011
  • Purpose: In this study we investigated improvement degree of reading ability of the student who was in a condition of dyslexia symptoms by wearing $ChromaGen^{TM}$ lenses. Methods: After wearing the $ChromaGen^{TM}$ lens for 3 months, the dyslexia symptoms corrective lens, 52 students who had suspected symptom of dyslexia were asked questions, and we measured the improvement degree of reading ability of the student. Results: The $ChromaGen^{TM}$ wearer read 110.26${\pm}$22.07 words in 1 minute, and naked yeses or glass wearing students read 106.42${\pm}$22.70 words. Reading ability of the student having suspected symptom of dyslexia were measured after wearing $ChromaGen^{TM}$ for 3 months. The results showed improvement reading ability of 3.70${\pm}$0.29 (p=0.01, t=2.26), 4.50%${\pm}$0.10 (p=0.01, t=2.78) for $ChromaGen^{TM}$ wearer with statistical difference. A survey on the satisfaction of reading improvement with wearing $ChromaGen^{TM}$ showed that 88.4% of questioned person answered wearing $ChromaGen^{TM}$ had improved their dyslexia symptoms. Conclusions: With statisical significance (p<0.05). this study suggests that $ChromaGen^{TM}$ lens has an effect on improving reading speed of dyslexia patient. We know from these results that the $ChromaGen^{TM}$ lens which is used to dyslexia had an effect to improvement of reading speed for dyslexia. And the results of this study is statistically different (p<0.05).

The Influence of Office Indoor Air Qualitys on the Dry Eye Symptom of Contact Lens Wearers (사무실 실내공기질과 콘택트렌즈 착용여부가 안구 건조증에 미치는 영향)

  • Kim, Dea Jong;Park, Moon Chan;Lee, Se Hoon;Kim, Hyun Uk;Lee, Wha Ja;Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.215-222
    • /
    • 2012
  • Purpose: This study was performed to investigate the influence of indoor air qualities of an office environment on dry eye syndrome for wearing contact lens and non-wearing contact lens. Methods: To study the effects of indoor air qualities on dry eye syndrome for seventy-one subjects, $CO_2$, temperature, humidity, TSP, PM10, HCHO were measured. Each subject was tested by a McMonnie's dry eye syndrome questionnaire, a Schirmer Tear Test-I (S.T.T-I), a Schirmer Tear Test-II with anesthetics (S.T.T-II), and Tear film break-up time (T.B.U.T) in the their offices. Results: There was significant relation between the indoor air quality and dry eye syndrome for wearing contact lens and non-wearing when TSP was over $200{\mu}g/m^3$, PM10 was higher than $86.7{\mu}g/m^3$ and Formaldehyde was over $0.4{\sim}1.0{\mu}g/m^3$. However, there was no significant effect on dry eye syndrome with $CO_2$ (p=.0146), temperature (p=0.074) and humidity (p=0.053). Conclusions: It was indicated that $CO_2$, temperature and humidity were no effect on dry eye syndrome in the office environment. However TSP, PM10, formaldehyde, and wearing contact lens were effect on dry eye syndrome. Therefore, the entire management of wearing contact lens and the individual evaluation of the indoor air quality are required.

Effects of Wearing between Respirators and Glasses Simultaneously on Physical and Visual Discomforts and Quantitative Fit Factors (안면부 여과식 방진마스크와 안경 동시 착용 시 불편감과 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.52-60
    • /
    • 2018
  • This study compares the differences of the fit factor by the order of wearing preference between Particulate filtering facepiece respirators(PFFR) and glasses when participants wore simultaneously and a survey of physical and visual complaint. Recognition level about fit of respirators was investigated and the educational (before- and after-) effect of the fit factor. When participants wore PFFR and glasses, physical complaints were nose pressure, slipping, nose and ear pressure, ear pressure and rim loosen, the most highly physical complaints were nose pressure. Visual complaints were demister, blurry vision, dizziness, visual field, and lens dirty, the most highly visual complaints were demister. But, there was significant difference in physical complaint such as nose pressure(10.3%), slipping (23.0%), nose and ear pressure(14.3%), and rim loosen(16.2%), visual complaint such as visual field(13.8%) and lens dirty(32.4%). For the recognition of fit of respirators, respirators fitness, leak site, an initial point and an object, faulty factor, recognition level was higher. Fit factor was increased after education of proper wearing of respirator. Change of the fit factor was smaller compared to the normal breathing and after 6 actions in case of after education. Questionnaire consisted of general characteristics and physical/visual complaint, recognition of fit. Complaints were measured after the QNFT with multiple choices. Quantitative fit factor was measured by device and compared the result of (before- and after-) educational effect. Also, we selected to 6 actions (Normal breathing, Deep breathing, Bending over, Turning head side to side, Moving head up and down, Normal breathing) among 8 actions OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The fit factor was higher after the training (p=0.000). Descriptive statistics, paired t-test, and Wilcoxon analysis were performed to describe the result of questionnaire and fit test. (P=0.05) Therefore, it is necessary to investigate the quantitative research such as training program and glasses fitting factor about the wearing of PFFR and glasses simultaneously.

The Wearing Effect of Sport Underwear -Focusing on the Loss of Weight and Amount of Sweat according to the Materials- (운동용 속옷의 착용효과 -소재별 발한량과 체중감량을 중심으로-)

  • Na, Mi-Hyang;Kim, Mi-Sun;Jung, Bock-Hee
    • Korean Journal of Human Ecology
    • /
    • v.11 no.3
    • /
    • pp.273-285
    • /
    • 2002
  • Three materials for sport underwear were manufactured by order for study, and among them, suitable material in order to perform an experiment on the effect of wearing was adopted. The results are as follows: The result of wearing an experimental clothes for sports manufactured as a foundation-type underwear for sports showed that if the same compositional materials were applied, laminating material had higher rate than that of others in the amount of sweat. Concerning relative humidity in clothes and the amount of sweat absorbed in clothes among the two kinds of materials which were produced by laminate, material 2(nylon+modal) was statistically exerts higher influence on the amount of sweat. The humidity in clothes keeps the optimal condition of 59.8%, and breast part showed the highest relative humidity. The material 2(nylon+modal) showed the highest comfortableness, the sense of warmth, humidity and voluminousness, and the sense of pressure. Follow-up survey revealed that in case of material 2, higher amount of sweat than that of the group objects in its early phase, and the amount of sweat varies from individuals. The temperature in clothes of folded parts of experimental clothes and maximum surface temperature was equivalent to that of average skin. With the lapse of time, the weight decreased of 11.03% in maximum, and 3.12% in minimum. The amount of change in the girth was greater in part of body frame than that of limbs, and especially, navel and waist part showed high decrease, and upper breast, breast and the largest part of abdomen showed relatively low decrease. The above experiment revealed that materials for suitable to the underwear for sports for loss of weight by an exercise should be made of doubled-nylon and modal, along with the laminate processing, which heightens the amount of sweat. Thus, wearing an experimental wear gave satisfaction in the view of the beauty of appearance as it did not discharge flowing secretion to the outside at the time of exercise.

  • PDF

The Effect of Circle Contact Lens on the Stability of Tear Film (써클콘택트렌즈가 눈물막 안정성에 미치는 영향)

  • Lee, Sehee;Hyung, Sung Min;Koh, Seung Hwan;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • Purpose: The effect of pigmentation in circle contact lens on lens wearers' tear film stability was investigated in this study. Methods: Non-invasive tear film break-up times of 54 normal eyes before and after lens wearing in twenties and the portion of first tear breakup were measured. The frontal and back surface roughness of circle contact lens was further observed with a scanning electron microscope. The clear lens which was made of hilafilcon B and circle contact lenses which were made of hilafilcon B, polymacon and copolymer of HEMA NVP were tested. Results: Non-invasive tear film breakup time was significantly reduced compared with it before lens wearing. In some case, statistically significant difference in tear film breakup time was also observed between circle contact lenses. The tear file break-up was usually early started in lower than upper portion, and in temporal than nasal portion although there was variation in the lens material. The tear film break-up of circle contact lenses made of hilafilcon B was more commonly observed in peripheral portion(pigmented area) compared with clear contact lens made of same material. Conclusions: The present study revealed that the stability of tear film was affected by wearing circle contact lens and the result seems to be used as the basis for the problem solving that can occur due to the pigmentation when wearing circle contact lens.

Color Image Segmentation and Textile Texture Mapping of 2D Virtual Wearing System (2D 가상 착의 시스템의 컬러 영상 분할 및 직물 텍스쳐 매핑)

  • Lee, Eun-Hwan;Kwak, No-Yoon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.5
    • /
    • pp.213-222
    • /
    • 2008
  • This paper is related to color image segmentation and textile texture mapping for the 2D virtual wearing system. The proposed system is characterized as virtually wearing a new textile pattern selected by user to the clothing shape section, based on its intensity difference map, segmented from a 2D clothes model image using color image segmentation technique. Regardless of color or intensity of model clothes, the proposed system is possible to virtually change the textile pattern or color with holding the illumination and shading properties of the selected clothing shape section, and also to quickly and easily simulate, compare, and select multiple textile pattern combinations for individual styles or entire outfits. The proposed system can provide higher practicality and easy-to-use interface, as it makes real-time processing possible in various digital environment, and creates comparatively natural and realistic virtual wearing styles, and also makes semi-automatic processing possible to reduce the manual works to a minimum. According to the proposed system, it can motivate the creative activity of the designers with simulation results on the effect of textile pattern design on the appearance of clothes without manufacturing physical clothes and, as it can help the purchasers for decision-making with them, promote B2B or B2C e-commerce.

Comparison of gait ability according to types of assistive device for ankle joint of chronic hemiplegic stroke survivors (발목관절 보조 도구에 따른 만성 뇌졸중 편마비 장애인의 보행 비교)

  • Park, Dong-Chun;Jung, Jung-Hee;Kim, Won-Deuk;Son, Il-Hyun;Lee, Yang-Jin;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.2
    • /
    • pp.30-39
    • /
    • 2021
  • Background: The purpose of this study was to compare the differences in gait and mobility according to the types of assistive device for ankle joint including ankle foot orthosis (AFO), non-elastic tape, elastic tape, and high ankle shoes in chronic hemiplegic stroke survivors. Design: A cross-over design. Methods: Twelve hemiplegic stroke survivors participated in this study, and they walked under 5 different conditions including bare feet, wearing a AFO, wearing a non-elastic tape, wearing a elastic tape, and wearing a high ankle shoes. During the participants walked, the spatio-temporal gait analysis and mobility examinations were performed. For the spatio-temporal gait analysis (gait velocity and cadence, step length, stride length, and single and double leg support time) and mobility examinations, the gait mat, TUG and TUDS were used. Results: As s results, on the AFO, non-elastic tape, elastic tape, and high ankle shoes, there were significantly differences in the all spatio-temporal gait parameters, TUG, and TUDS compared to barefoot (p<0.05). In particular, all spatio-temporal gait parameters, TUG, TUDS were significantly improved with AFO compared to barefoot. TUG was significantly improved with AFO compared to non-elastic tape, TUG and TUDS were significantly improved with AFO compared to elastic tape, gait velocity was significantly improved with non-elastic tape compared to high ankle shoes, gait velocity and TUG were significantly improved with elastic tape compared to high ankle shoes, and TUDS was significantly improved with non-elastic tape compared to elastic tape. Conclusion: The AFO, non-elastic tape, elastic tape, and high ankle shoes showed a positive effect on gait and mobility compared to barefoot, and among them, wearing AFO was most effective for improving gait and mobility of chronic hemiplegic stroke survivors.

The effect of images of saleswomen on customer satisfaction and revisiting intention by uniform and body type (판매원의 유니폼과 체형에 따른 이미지가 고객만족 및 재방문의도에 미치는 영향)

  • You, Eun-Sung;Park, Kil-Soon
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.2
    • /
    • pp.166-179
    • /
    • 2016
  • The purpose of this study was to identify images of saleswomen by uniform and body type and to determine if the images have an effect on customer satisfaction and revisiting intention. This study was conducted between February 10th and February 23rd 2015, using a questionnaire to collect data from 608 adults from Seoul, Deajeon, and Chungnam Province. A $2{\times}2$ (body $type{\times}clothes$) factorial experimental design was used. Frequency, factor, and reliability analysis, analysis of variance, one-way ANOVA, Tukey test, and multiple regression analysis methods were used to analyze data. The study results were as follows: First, images of saleswomen with different uniform and body types were classified based on the following three factors: professionalism, kindness and attractiveness. Second, the saleswomen's uniforms had significant impact on perceived attractiveness, with women who wore skirt suits being identified as more attractive than women with pant suits. The saleswomen's body types had significant effect on professionalism, kindness and attractiveness. Women with average body types were perceived positively in terms of professionalism and attractiveness, whilst women with large body types were perceived positively in terms of kindness. Third, the combination of uniform and body type had a significant effect on perceived professionalism. Women with average body types wearing pant suits were perceived to have high degree of professionalism and women with large body types wearing skirt suits were evaluated to have high professionalism. Fourth, the images described as attractive and kind for both uniform and body type had a positive influences on customer satisfaction and revisiting intention.