• 제목/요약/키워드: Wearer

Search Result 374, Processing Time 0.019 seconds

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF