• Title/Summary/Keyword: Wear loss

Search Result 416, Processing Time 0.032 seconds

PERIODONTAL DISEASE CAUSED BY TRAUMA FROM OCCLUSION IN A CHILD (외상성 교합으로 인한 어린이의 치주질환)

  • Choi, Byung-Jai;Ko, Dong-Hyun;Kim, Seong-Oh;Lee, Jae-Ho;Son, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.448-452
    • /
    • 2004
  • Trauma from occlusion(TFO) is injury to the periodontal tissue as a result of occlusal forces. Mobility is a common clinical sign of occlusal trauma. In acute occlusal trauma, this may be accomanied by pain, tenderness to percussion, thermal sensitivity, and pathologic tooth migration. Chronic occlusal trauma may be marked by excessive wear and gingival recession. Radiographic finding include a widened periodontal ligament space, radiolucence and condensation of the alveolar bone and root resorption. TFO is related to the pathogenesis of periodontal disease. It can cause increased tooth mobility TFO itself does not initate or aggravate marginal gingivitis or initiate periodontal pockets. Active trauma can accelerate bone loss, pocket formation and gingival recession depending on the presence of local irritants and inflammation. Gingival recession associated with occlusal forces includes traumatic crescent, McCall's festoon and Stillman's cleft. TFO plays a minor role in the pathogenesis of early to moderate periodontitis. A 5-year-old male visited Yonsei University Pedodontics clinic with a chief complaint about gingival recession. Mobility, excessive wear, gingival recession were detected by clinical exam on the both mandibular deciduous ca nine. On the radiographic view, vertical alveolar bone loss was observed on both mandibular deciduous canine.

  • PDF

Full-mouth rehabilitation of a patient with reduced occlusal vertical dimension due to severe wear: a clinical report (심한 마모로 인하여 교합 고경이 감소된 환자의 완전 구강 회복술)

  • Kim, Min-Jung;Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.39-46
    • /
    • 2013
  • The loss of posterior support may cause attrition of anterior teeth, and loss of occlusal vertical dimension (OVD). The collapse of the posterior support will eventually cause the pathologic change of the TMJ and masticatory muscles, unesthetic facial appearance and decreased masticatory function. Patients with destroyed dentition need extensive prosthetic treatments. Proper diagnosis and treatment planning are necessary for the stability of the neuromuscular system and the TMJ, and esthetic and functional definitive restorations. In this case, 63 year-old male presented with decreased masticatory force and esthetic problems due to pathologic destruction of teeth structure on entire dentition. Based on assessment of OVD including intraoral findings, radiographic examination and diagnostic cast, full-mouth rehabilitation with increase of OVD was planned using fixed partial denture and removable partial denture. Diagnostic wax-up was done after 4 mm increase of OVD determined by assessment of OVD. The OVD was maintained with the overlay type removable interim prostheses for 12 weeks to ascertain his comfort and adaptation to the new OVD. After the adaptation period, second interim prostheses with tooth preparation maintaining the established OVD was delivered. After 4 weeks, final prostheses were fabricated and delivered. After 7 month follow-up period, occlusal stability is maintained. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Full Mouth Rehabilitation in a Patient with Limited Restorable Space (수복 공간이 부족한 환자에서의 완전구강회복)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.145-156
    • /
    • 2010
  • Loss of posterior support may cause overloading and excessive wear of remaining teeth. Moreover, the extrusion of antagonistic teeth leads to the destruction of the occlusal plane. The loss of vertical dimension of occlusion (VDO) also emerges clinically, which may bring the loss of esthetic appearance and function. These patients who suffer from the loss of posterior support, often require vigorous periodontal treatments (osteotomy, crown lengthening) and extensive oral rehabilitation. Sixty three years old female patient visited for the prosthetic treatment of the posterior edentulous area. She had no other systematic disease and parafuctional habits for prosthetic treatment. Intraoral and radiographic examinations were done. The evaluation of VDO and vertical dimension of rest position were evaluated for proper prosthetic procedures and diagnostic wax up was done. As a result of diagnosis, VDO was increased by 2 mm considering the loss of VDO and space for the prosthetic treatment. After the pretreatments, initial preparation of teeth and provisionalization were carried out. Six weeks later of provisionalizaion, final preparation and impression was performed. Using the duralay resin copings, jaw relation was registered. The master cast was mounted and definitive restoration was fabricated. After the evaluation of esthetic and function, pick up impression for clinical remounting was done. Lucia jig was made for new jaw relation and occlusal adjustment on the articulator. Definitive restoration was delivered and the patient was periodically recalled for additional occlusal adjustment. From this case, the satisfactory functional and esthetic results through full mouth rehabilitation with increase vertical dimension were achieved.

Full mouth rehabilitation of the patient with worn dentition using full-contour monolithic zirconia prostheses at an increased vertical dimension of occlusion: a case report (치아 마모 환자에서 수직고경 증가를 동반하여 단일구조 지르코니아 보철물로 완전구강회복을 시행한 증례)

  • Oh, Kyung-Chul;Chung, Moon-Kyu;Kim, Jee-Hwan;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.198-203
    • /
    • 2012
  • Excessive occlusal wear results in unacceptable damage to the occluding surfaces, and can cause pulpal injury, occlusal disharmony, impaired function, and aesthetic deformity. Patients with severely worn dentition need to be classified as several categories relative to the vertical dimension of occlusion (VDO) and the interocclusal distance for the prosthetic space. When treating patients classified as those who have excessive wear without loss of occlusal vertical dimension but with limited space, we could consider treating them at an increased vertical dimension of occlusion. Treatments at an increased vertical dimension of occlusion may provide stability, given that the amount of its increase was minimal, and a perfected occlusion was achieved after enough stabilization period. A 50-year-old male visited the department of Prosthodontics in Yonsei University Dental Hospital with the chief complaint of worn teeth on lower anterior area. Reconstruction at an increased vertical dimension of occlusion was planned. After the compatibility of the new vertical dimension of occlusion had been confirmed under interim fixed restorations, definitive fixed restorations composed of full-contour monolithic zirconia prostheses were placed. This case presents that a satisfactory clinical result was achieved by restoring the worn dentition at an increased vertical dimension of occlusion with an improvement in esthetics and function.

Evaluation of the wear of the periodontal curet's cutting edge (치주 큐렛의 절단 연 마모도 평가)

  • Park, Eung-Joon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.575-584
    • /
    • 1997
  • The quality of periodontal instrument cutting edge is a basic element of effective root planing procedure. Using instruments, the sharp edge is changed into blunt or beveled edge. With the blunt instrument, the periodontal treatment can't be carried into accuracy and effective. The study on the wear of periodontal curet is insufficient, there are few publications about the change of sharpness of cutting egde after using instrument and a certen reports were published on the study of scanning electron microscope(SEM) examination. In this study, to declare the number of strokes for sharpening of instruments, the changes of cutting edge is measured by the clinical methods, tactile sensitivity examination and refraction light-white line test after scaling strokes and root planing strokes. SEM test was added for defined the changes of cutting edges. The 7/8 Gracey curets that have been never used was tested. Maxillary molars which were extracted from the School of Dental Medicine, Dankook University was used. Subjected teeth had attachment loss more than 6 mm in bucca-lingual surface and sufficient calculus of a band type in cervical area. The strokes of curet were executed 3, 5, 7, 9, 11, 13 times on scaling stroke and 10, 15, 20, 25, 30, 35 times on root planing stroke. A resident has periodontal experience over 3 years carried out the clinical examinations those tactile sensitivity examination and refraction light-white line test 5 times. The case there being tactile sensitivity certenly is 2, the case being felt tactile sensitivity is 1, and the case there not being tactile sensitivity is 0. The visual examination was recorded as following. The case that refracted white line is not recognised is 2, the case that uncerten is 1, and the case that acknowledged is 0. The results were obtained as follows. 1. After scaling strokes, the tactile sensitivity was reduced after 11 strokes and disappeared in 13 strokes. 2. In tactile sensitivity after root planing procedures, sensitivity was reduced after 25 strokes and disappeared in 35 strokes. 3. In case of visual examination, the detection of refracted white line was increased after 9 strokes of scaling procedures and the accuracy of wear wasn't showed after root planing procedures. 4. In SEM, metal projection was observed on new periodontal curet cutting edge and it was disappeared after scaling procedures. 5. In SEM, the cutting edge was showed changing linear into an aspect of the surface after 5 strokes of scaling procedures and 10 strokes of root planing procedures and showed beveled edge in 11 strokes of scaling procedures, 25 strokes of root planing procedures. The results of 3-type examination indicated that the sharpening of curet should be performed after 11 strokes of scaling procedures and 25 strokes of root planing procedures.

  • PDF

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

Full mouth rehabilitation using removable partial denture in patient with loss of vertical dimension due to worn dentition (심한 치아 마모로 인해 수직 고경이 상실된 환자에서 국소 의치를 이용한 전악 수복 증례)

  • Shim, Eun-Young;Lee, Na-Young;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.347-353
    • /
    • 2018
  • Gradual attrition is a normal process of aging, but severe attrition causes occlusal disharmony, functional disorder and esthetic problems. The collapse of posterior support may cause attrition of anterior teeth, and loss of occlusal vertical dimension (OVD). And it induces the pathologic change of the TMJ, unaesthetic facial appearance and decreased masticatory function. In this case, 70 year-old male presented with decreased vertical dimension and esthetic problems due to worn dentition. Based on assessment of intraoral findings, diagnostic cast and radiographic examination, full-mouth rehabilitation with increase of OVD was planned. After 10 month follow-up, occlusal stability is maintained and through this procedure, satisfactory outcomes were achieved in esthetic and functional aspects.

Wear, microleakage and plastic deformation of an implant-supported chair-side bar system

  • Mehl, Christian Johannes;Steiner, Martin;Ludwig, Klaus;Kern, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2015
  • PURPOSE. This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+$M{\acute{e}}taux$, Switzerland). MATERIALS AND METHODS. Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, ${\alpha}{\leq}.05$). RESULTS. All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION. Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.

Effects of wearing sweat suit on sweating rate (I) - During 30min jogging with the speed of 3.6miles/h and the room temp. of $22^{\circ}C$ - (땀복착용이 운동시 발한에 미치는 영향 (제1보) - 환경온 $22^{\circ}C$ 실내에서 3.6miles/h 속도로 30분 조깅시 -)

  • 정영옥
    • Korean Journal of Rural Living Science
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • The purpose of this study is to investigate the effect of wearing sweat suit on sweating rate during jogging. 4 healthy female students served as subjects in the experimental chamber which was controlled 22$\pm$1$^{\circ}C$, 60$\pm$10%RH and no wind. The experimental clothes were Sweat Suit (SS) and General Suit (GE), SS was the product of R sports wear company which was consisted of long-sleeved jumper (100% polyester) and full length trousers (100% polyester) and GE were consisted of long sleeved shirt (100% cotton) and full length trousers (100% cotton). The subject wore same socks and shoes in both experimental clothes SS and GE. The subject reported at the experimental chamber at the same time on each experimental day. exchanged their clothes to the experimental clothes SS or GE, wore all sensors for the physiological measurements and had a rest in a sitting posture about 40 minutes. After rest, the subject carried out 30 min jogging on the tread mill with the speed 3.6miles/hour and during the jogging rectal temperature, skin temperatures (7 sites of the skin surface), heart rate, VO2, and evaporative weight loss were measured continuously and compared between two experimental clothes SS and GE. The major findings were as follows : The increase in rectal temperature during 30 min jogging was higher in experimental clothes SS than in GE and mean slim temperature kept higher in SS than in GE. VO2 and heart rate were a little bit higher in the later period of jogging in SS than in GE. The evaporative weight loss was greater in SS than in GE. These results indicate that the thermophysiological responses and sweating rate differs according to the wearing suit even though the subject performed same exercise.

  • PDF

Internal Flow Analysis of Seawater Cooling Pump using CFD (CFD를 이용한 해수냉각펌프의 내부유동 분석)

  • Bao, Ngoc Tran;Yang, Chang-jo;Kim, Bu-gi;Kim, Jun-ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.1
    • /
    • pp.104-111
    • /
    • 2017
  • This research focuses on simulation and visualization of flow field characteristics inside a centrifugal pump. The 3D numerical analysis was carried out by using a numerical CFD tool, addressing a Reynolds Average Navier-Stock code with a standard k-${\varepsilon}$ two-equation turbulence model. The simulation accounts for friction head loss due to rough walls at suction, impeller, discharge areas and volumetric head loss at impeller wear ring. A comparison of performance curves between simulation and experimentation is included, and it reveals a same trend of those results with a small difference of maximum 5 %. At best efficiency point, velocity vectors are smooth but it changes significantly under off-design point, a strong recirculation appears at the outlet of impeller passages near tongue area. A relatively uniform preassure distribution was observed around the impeller in despite of the tongue. Within the volute, because of its geometry, spiral vortexes formed, proving that the flow field in this region was relatively turbulent and unsteady.