• Title/Summary/Keyword: Wear loss

Search Result 415, Processing Time 0.026 seconds

A case of full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to tooth wear (치아 마모로 인한 수직고경감소와 과개교합을 가진 환자에서 전악 수복 증례)

  • Seo, Seong-Yong;Lee, Na-Young;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • The collapse of the posterior occlusion destroys the normal occlusal plane and causes excessive wear reducing the vertical dimension. Reduced vertical dimension of occlusion causes not only aesthetic and functional problems but also overloading on the temporomandibular joints and abnormalities of muscle nerve system. In order to improve the collapsed occlusal relationship, it is necessary to consider the change of the vertical dimension. It is necessary to make a precise diagnosis and analysis before the treatment and to evaluate the adaption of patient to the new vertical dimension of occlusion. A patient with excessive overbite often has occlusal problems of tooth wear and tooth eruption. Considering these considerations, overall prosthodontic restoration is required to solve the problem. A patient of 68 year old man in this case who suffered major tooth wear and maxillary posterior teeth loss was treated with elevation of vertical dimension of occlusion by maxillary removable dental prosthesis and mandibular fixed prosthesis.

The Effects of the Incident Nitrogen Ion Dose on the Plasma Immersion Ion Implantation of Nimonic 80A (Nimonic 80A의 PIII에 미치는 질소이온주입량의 영향)

  • You, Y.Z.;Chun, H.G.;Kim, D.I.;Cha, B.C.;Koo, K.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.6
    • /
    • pp.369-374
    • /
    • 2005
  • Nitrogen ion implantation in Nimonic 80A using plasma immersion ion implantation (PIII) was investigated at a pulse voltage of -60 kV and ion dose of $3{\times}10^{17}{\sharp}/cm^2$, $6{\times}10^{17}{\sharp}/cm^2$, $12{\times}10^{17}{\sharp}/cm^2$. PIII is an effective technology to improve the surface hardness and wear resistance of materials. And also this technology is not limited by the shape and size of materials. PIII would be a promising technique in the future. Surface hardness and wear resistance of the $N^+$ ion implanted Nimonic 80A were increased with the increase in the incident ion dose. The surface hardness of the untreated Nimonic 80A is 420 Hv, the hardness of implanted Nimonic 80A is 1050 Hv at $N^+$ ion dose of $12{\times}10^{17}{\sharp}/cm^2$. The wear loss of the untreated is 82.5 mg, the wear loss of the implanted is 0.004g at $N^+$ ion dose of $12{\times}10^{17}{\sharp}/cm^2$. The $Cr_2N$ is detected on the surface of the implanted Nimonic 80A by XRD analysis.

Simulated occlusal adjustments and their effects on zirconia and antagonist artificial enamel

  • Alfrisany, Najm Mohsen;Shokati, Babak;Tam, Laura Eva;De Souza, Grace Mendonca
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.162-168
    • /
    • 2019
  • PURPOSE. The aim of this study was to evaluate the effect of occlusal adjustments on the surface roughness of yttria-tetragonal zirconia polycrystal (Y-TZP) and wear of opposing artificial enamel. MATERIALS AND METHODS. Twenty-five Y-TZP slabs from each brand (Lava, 3M and Bruxzir, Glidewell Laboratories) with different surface conditions (Control polished - CPZ; Polished/ground - GRZ; Polished/ground/repolished - RPZ; Glazed - GZ; Porcelain-veneered - PVZ; n=5) were abraded (500,000 cycles, 80 N) against artificial enamel (6 mm diameter steatite). Y-TZP roughness (in ${\mu}m$) before and after chewing simulation (CS) and antagonist steatite volume loss (in $mm^3$) were evaluated using a contact surface profilometer. Y-TZP roughness was analyzed by three-way analysis of variance (ANOVA) and steatite wear by two-way ANOVA and Tukey Honest Difference (HSD) (P=.05). RESULTS. There was no effect of Y-TZP brand on surface roughness (P=.216) and steatite loss (P=.064). A significant interaction effect (P<.001) between surface condition and CS on Y-TZP roughness was observed. GZ specimens showed higher roughness after CS (before CS - $3.7{\pm}1.8{\mu}m$; after CS - $13.54{\pm}3.11{\mu}m$), with partial removal of the glaze layer. Indenters abraded against CPZ ($0.09{\pm}0.03mm^3$) were worn more than those abraded against PVZ ($0.02{\pm}0.01mm^3$) and GZ ($0.02{\pm}0.01mm^3$). Higher wear caused by direct abrasion against zirconia was confirmed by SEM. CONCLUSION. Polishing with an intraoral polishing system did not reduce the roughness of zirconia. Wear of the opposing artificial enamel was affected by the material on the surface rather than the finishing technique applied, indicating that polished zirconia is more deleterious to artificial enamel than are glazed and porcelain-veneered restorations.

Mandibular full-arch rehabilitation with increased vertical dimension of a patient with severe tooth wear (심한 치아 마모 환자의 수직 교합고경 증가를 동반한 하악 편악 수복 증례)

  • Kim, Hyun-Jin;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.162-170
    • /
    • 2022
  • In the case of patients with pathological tooth wear, it is necessary to evaluate the loss of the vertical dimension. Setting the appropriate vertical dimension is important to rehabilitate the patient's stable intermaxillary relationship. A 77-year-old female patient's chief complaint was the pain of the mandibular incisors and the lack of molars. At the first visit, pathologic tooth wear of the mandibular incisors were observed. After diagnosis and evaluation, loss of vertical dimension was not observed, but insufficient intermaxillary space for prosthetic restoration was confirmed. Mandibular rehabilitation was performed with vertical dimension increase and this showed satisfactory results both functionally and aesthetically.

The Effect of Nitrogen Plasma Treatment on Tribological Behaviors of Plasma-sprayed Zirconia Coatings

  • Lim, Dae-Soon;Shin, Jong-Han;Lee, Jung-Yeob;Cho, Chang-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.7
    • /
    • pp.602-607
    • /
    • 2001
  • Zirconia powder containing 3 mol% yttria (3Y-PSZ) was casted on the cast iron substrate by plasma spraying method. Coated specimens were then heat treated at 500$\^{C}$ in nitrogen plasma. Wear tests were performed on nitrogen heat treated and non heat treated samples at temperatures from 25$\^{C}$ to 600$\^{C}$. Wear results showed that the friction coefficient and the wear loss of both the treated and the non-treated samples showed maximum value at 400$\^{C}$. These results were explained by low temperature thermal degradation due to the monoclinic transformation. Nitrogen plasma treatment significantly improved the tribological performance. The effect of nitrogen heat treatment on tribological behavior was explained by the increased micro-hardness and decreased monoclinic faction.

  • PDF

기계적 마모로 인한 교합 고경 상실 환자의 전악 수복

  • O, Nam-Sik;Kim, Hyo-Jeong;Ryu, Hyo-Jin;Kim, Il-Gyu;Choe, Jin-Ho
    • The Journal of the Korean dental association
    • /
    • v.41 no.1 s.404
    • /
    • pp.48-53
    • /
    • 2003
  • The purpose of this study is to report a clinical case of a patient whose vertical dimension of occlusion was lost. There are many reasons for the loss of vertical dimension and one of those can be a tooth wear problem. Thus in this article we will review shortly types of tooth wear: attrition, abrasion, and erosior. And layour the basic philosophy and principles in regaining the esthetics and function of a patient's oral condition with a history of psychological wear, through full mouth restorations.

  • PDF

Microstructure and Tribological Characteristics of AlSi-Al$_2$O$_3$ Composite Coating Prepared by Plasma Spray (플라즈마 용사에 의한 AlSi-Al$_2$O$_3$ 복합재료 코팅층의 미세조직 및 마찰.마모특성)

  • Min Joon-Won;Yoo Seung-Eul;Kim Young-Jung;Suhr Dong-Soo
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2004
  • AlSi-Al$_2$O$_3$ composite layer was prepared by plasma spray on steel substrate. The composite powder for plasma spray was prepared by simple mechanical blending. The wear resistance of the composite layers and matrix aluminum alloy were performed in terms of size distribution of ceramic particles. Friction coefficients of AlSi were decreased with incorporation of $Al_2$O$_3$. The tribological properties of coated layers were affected by the size of incorporated $Al_2$O$_3$ particle. The reinforcement of $Al_2$O$_3$ particle into aluminum alloy matrix decreased the friction coefficient as well as wear loss.

The Wearing Sensation of Men and Women in Sports Wear with Waterproof and Water Vapor Permeable Fabrics (성인 남녀의 투습방수소재 스포츠 웨어의 소재별 착용감에 관한 연구)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.9 no.1
    • /
    • pp.47-61
    • /
    • 2000
  • The purpose of this study was to examine the performance and properties of sports wear that have the excellent wearing sensation and are in harmony with the functions of human bodies. With four kind(sample A, B, C, D) of materials which have different water vapor transmission, the physiological responses of human bodies and the changes of subjective sensations were studied through the actual aerobic sports program at $20^{\circ}C$, 60%R.H. The forehead temperature had the minimal variation among the local skin temperatures. The fabrics of low water vapor transmission demonstrated high breast temperature. There are significant differences among materials depending on the humidity in clothes(especially back and breast), which was about 6 % for breast and about 14 % for back. The order of loss in body weight was in the opposite direction to that of water vapor transmission for each material.

  • PDF

A study on the effects of Ni content on the properties of wear resistant for the high manganese steel castings (고Mn강 주강품의 내마모성에 미치는 Ni첨가의 영향에 관한 연구)

  • Lee, Young-Hun;Cheon, Byung-Wook;Kim, Sung-Han;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.12 no.2
    • /
    • pp.155-161
    • /
    • 1992
  • This study has been performed in increase the wear resistance characteristic and the mechanical properties of high Mn steel castings with an addition of Ni to $1{\sim}4%$ range. The initial structure of plastic cememtite has been possible to transform perfect austenite with watertoughening treatment. Increasing Ni content, the most wear loss has shown that ore has crushed until 100kg and decreased with increasing ore amount at ascast, the similar tendency has shown at heat treatment. Chang of hardness has shown high values that ore has been crushed until 300kg, both as cast and treatment added 2%Ni.

  • PDF

Roll의 수명예측 model 개발

  • 배용환;장삼규;이석희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.306-312
    • /
    • 1992
  • The prevention of roll breakage in hot rolling process is improtant to reduce maintenance cost and production loss. Rolling conditions such as the roll force and torque have been intensively studied to overcome the roll breakage. in the present work, a model for life prediction of work rolls under working condition was developed and discussed. The model consists of stress analysis, crack propagation, wear and fatigue calculation model. Roll life can be predicted by stress, crack depth and fatigue damage calculated from this model. The reliability of stress analysis is backed up by the FEM analysis. From the result of simulation using by pressent model, although the fatigue damage of back up roll reachs 80% of practical limit, that of workroll was less than 40%. In edge section of workroll stress amplification is found by wear and bender effect. We can judge that workroll failures are not due to fatigue damage, crack propagation by bending stress but stress amplification by wear and bender in present working condition.