• Title/Summary/Keyword: Wear

Search Result 7,449, Processing Time 0.033 seconds

A Field Test Assessment on the Extremity Doses of Highly-Exposed Radiation Workers During Maintenance Periods at Nuclear Power Plants in Korea (원전 계획예방정비기간 고피폭 접촉작업에서 방사선작업종사자의 말단선량 평가 현장시험)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • Maintenance on the water chamber of steam generator, the change of pressurizer heater, the removal of pressure tube feeder, and so on during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, field tests on extremity dose assessment of radiation workers for contact works with high radiation exposure were conducted during the maintenance periods in Korean pressurized water reactors (PWRs) and pressurized heavy water reactors (PHWRs). In this field test, radiation workers were required to wear additional TLDs on the back and wrist, and an extremity dosimeter on fingers including a main TLD on the chest, while performing maintenance. As a result, it was found that the equivalent dose for fingers was distributed in the fixed range of deep dose and the equivalent dose for wrists.

Optimal Process Planning of CNG Pressure Vessel by Ensuring Reliability and Improving Die Life (CNG 압력용기의 최적 공정설계를 통한 공정의 신뢰성 확보 및 다이 수명 향상)

  • Bae, Jun Ho;Lee, Hyun Woo;Kim, Moon Saeng;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.7
    • /
    • pp.865-873
    • /
    • 2013
  • The deep drawing and ironing (DDI) process involving the use of a high-capacity horizontal press is used for manufacturing acompressed natural gas (CNG) pressure vessel. However, some variables of the DDI process have been determined based on the experiences of workers, and the short die life needs to be improved for manufacturing the pressure vessel withhighquality and lowcost. In this study, process variables such as the draw ratio, distance between dies, radius of rounding of drawing die, and angle of ironing die are chosen to enhance the reliability and improve the die life based on previous studies and experiences. The draw ratio limits at which no tearing or wrinkling occurs are determined using FEA, and the distances between dies, radius of rounding of drawing die, and angle of ironing die are optimized by the DOE method. The results of the optimal process variables are compared with those of the existing DDI process for verifying their effectiveness.

A Study on Dye Elution from the Circle Contact Lenses (써클콘택트렌즈의 염료 용출에 대한 연구)

  • Kim, So Ra;Kang, Ura;Seo, Bo Min;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.171-177
    • /
    • 2014
  • Purpose: The present study was conducted to investigate whether the elution of the dyes from the circle contact lenses existed or not when rubbed with cotton swab. Methods: The change of lens surface was observed by scanning electron microscope when a total of seven kinds of circle contact lens were rubbed with cotton swab, and the dye elution was further compared when the lenses were soaked in multi-purpose solution in $20^{\circ}C$ and $36.5^{\circ}C$ for a week. Results: Five of a total of 7 circle contact lenses showed the dye elution from the front or the back surface of the lens when rubbed with cotton swabs, and existence of dye elution was varied depending on the type of contact lenses and different at the front and back surface even in the same lens. The tear-off of the pigmented portion by the rubbing was found through scanning electron microscopic observation when the dye elution existed. However, the dye was not eluted when the circle contact lenses was soaked in a multi-purpose solution in $20^{\circ}C$ or $36.5^{\circ}C$ for a week. Ingredient of colorant was not provided by the manufacturers in more than 50% of the circle contact lenses investigated for this study and the basic information such as the pigmentation method was provided inappropriately. Conclusions: In this study, the result was the dye elution from circle contact lenses was obtained when a physical force is applied thus, it may appear to contribute the development of circle contact lenses and safety of lens wear.

A Study on the Model Test for Pneumatic Mine-Filling (공압식 갱내충전을 위한 모형실험 연구)

  • Yang, In-Jae;Shin, Dong-Choon;Yoon, Byung-Sik;Mok, Jin-Ho;Kim, Hak-Sung;Lee, Sang-Eun
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.449-463
    • /
    • 2014
  • There are many case studies and application cases in abandoned mines for hydraulic filling method filled by slurry or paste form, but research on the pneumatic filling is not applied in Korea. The damage of steel pipe is occurred by wear due to the flow of filling material in the bent area of steel pipe in traditional pneumatic filling method. In this study, the new pneumatic filling method was developed using a newly devised improved nozzle to improve the above problem. The model test for mine filling was performed in the laboratory for the simulated accessible or inaccessible mine cavities, and the filling efficiency by the results obtained from the test was calculated. The filling efficiency was analyzed from the variation of outlet angle, feed rate and grain size of sand in model test of simulated accessible mine cavity. The superiority of improved pneumatic filling method was proved through the analysis of filling efficiency by the results obtained from each model tests of gravitational, traditional, and improved filling method in simulated inaccessible mine cavity.

Development and Characteristics of New Cultivar 'Green Ever' in Zoysiagrass (한국잔디 신품종 '그린에버'의 개발 및 특성)

  • Tae, Hyun-Sook;Hong, Beom-Seok;Shin, Chong-Chang;Jang, Gong-Man;Kim, Kyung-Duck;Park, Dae-Sup
    • Weed & Turfgrass Science
    • /
    • v.3 no.4
    • /
    • pp.329-335
    • /
    • 2014
  • This study was performed to study characteristics of new zoysiagarass cultivar 'Green Ever' (Plant Variety Protection Application no. 2014 - 02). 'Green Ever' was developed by selection breeding among 100 native zoysiagrasses collected in South Korea. 'Green Ever' showed specific bands (1.48 kb with OPC14 and 1.05 kb with OPD5) which were distinct from 'Anyang Joonggi' or 'Dongrae Koryogi' in RAPD analysis. 'Green Ever' was classified as Z. matrella in morphological evaluations including plant height ($6.8{\pm}0.5cm$), leaf width ($2.0{\pm}0.1mm$), height of lowest leaf ($1.9{\pm}0.1cm$) and seed length ($3.0{\pm}0.1mm$), which was similar with morphological characteristics of 'Dongrae Koryogi'. Turf quality, shoot density and chlorophyll content of 'Green Ever' were higher than them of 'Anyang Joonggi' and 'Dongrae Koryogi' under intensive management such as fairway on golf course, especially shoot densities of 'Green Ever' were excellent higher than 'Anyang Joonggi' and 'Dongrae Koryogi' during experimental periods. It could be extensively used in fairway, teeing ground of golf courses and landscape garden after further study about various environmental adaptabilities such as winter kill, wear tolerance etc.

A Comparative Study on the Skinny Jean Pants Pattern and the Wearing Evaluation for Males in Their 20s (20대 남성용 스키니 진 팬츠 패턴개발을 위한 착의평가 및 패턴비교분석)

  • Lee, Seong Hee;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.6
    • /
    • pp.873-886
    • /
    • 2014
  • This study conducted a survey on jean pants that targeted males in the 20s in order to select preferred brands for skinny jean pants. Preliminary data for the pattern development of skinny jean pants was presented through functionality evaluation, appearance evaluation and pattern analysis. The results were as follows. 1. The result of survey targeting males in the 20s to select the design and brand name of jean pants showed that skinny jean pants were selected as the most favorite type of jean pants to wear; in addition, non-brand products and brand names such as Uniqlo and Levi's were also preferred. 2. The result of functionality evaluation showed that L brand received a high score in all items except for items regarding the knee circumference and mid-thigh circumference, S brand received a high score as well as a low score, and N brand received a low score in general. The result of appearance evaluation showed that L brand for the waist height and waist circumference, N brand for the brand crotch circumference, posterior crotch length and knee circumference, and S brand and N brand for the length of pants were preferred. 3. The result of pattern measurements analysis from the result of functionality evaluation showed that L brand provided a large pattern measurement for the waist height, L brand provided less ease due to small pattern measurements for waist circumference; in addition, N brand for the knee circumference and mid-thigh circumference were preferred. 4. The analysis result shows that a ease of 5cm based on the belly band which is 3.5cm below the belt width is proper for the waist circumference when designing a skinny jean pant pattern and 4cm for the hip circumference and 32.5cm for the ease of crotch circumference are proper, -0.4-0cm for the ease of mid-thigh circumference and knee circumference in consideration of human body measurements; therefore, 80.1-80.5cm for inseam as the length from the crotch height to the leg length, 25.7cm for vertical hip length and 53.0cm for crotch length are proper.

Study on Structural Integrity and Dynamic Characteristics of Knuckle Parts of KTX Anti-Roll Bar (KTX 고속열차 안티롤바 너클부의 동특성 및 구조 안전성 평가)

  • Jeon, Kwang Woo;Shin, Kwang Bok;Kim, Jin Woo;Jeong, Yeon Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1035-1041
    • /
    • 2013
  • To evaluate the structural integrity and dynamic characteristic of the knuckle part of a KTX anti-roll bar, an experimental and a numerical approach were used in this study. In the experimental approach, the acceleration and strain data for the knuckle parts of the KTX and KTX-SANCHUN anti-roll bar were respectively measured to evaluate and compare its structural dynamic characteristics under the operating environments of the Honam line. In the numerical approach, the evaluation of its structural integrity was conducted using LS-DYNA 3D, and then, the reliability of the finite element model used was ensured by a comparative evaluation with the experiment. The numerical results showed that the stress and velocity field of the knuckle part composed of a layered structure of a thin steel plate and rubber were more moderate than those of the knuckle part made of only a thick steel block owing to the reduction of relative contact between the knuckle and the connecting rod. It was found that the knuckle part made of a thin steel plate and rubber was recommended as the best solution to improve its structural integrity resulting from the elastic behavior of the KTX anti-roll bar being enabled under a repeating external force.

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

Abrasion-Resistant Road Markings for Improved Durability Lane to Wear Simulators Test (차선재료의 내구성 향상을 위한 내마모성 시험 적용 연구)

  • Lee, Chang-Geun;Park, Jin-Hwan;Oh, Heung-Un
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.75-82
    • /
    • 2011
  • There is the uncertain period of the construction in case of the products meeting the quality standard of KS M 6080, the quality is degraded because of the abrasive loss of the paint caused by vehicle tires as the traffic amount increases and of the loss and detachment of the glass beads providing the retroreflective function. The abrupt degradation of visibility causes the high frequency of traffic accidents at night and increases the traffic accident rate. Additional supplementary construction induces the direct material and construction costs. As the more cost induction effect than the direct cost, the traffic jam caused by the additional construction increases the indirect social costs such as time cost and vehicle cost. Hence, the study is concerned with performing the abrasion resistance test based on the EN 1436 standard to check and improve the quality of various road marking materials resulting in improving the durability of road marking materials. However, even though the difference in the durability lifetime of resins(binders) is bibliographically or theoretically clear, there was no difference in the durability lifetime (retroreflectivity aspect) of the road marking paint using these binders. The reason is that the bonding of beads was very insufficient or that the cross density caused by crack or freshness was low. Moreover, the measured wet retroreflectivity was distributed as the Rw3 or higher class in average on the basis of EN 1436 but was very insufficient on the basis of the minimum wet threshold retroreflectivity with 100mcd/($m^2{\cdot}lx$) managed overseas.

Development of u-Health Care System for Dementia Patients (치매환자를 위한 u-Health Care 시스템 개발)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1106-1113
    • /
    • 2013
  • For patients who have senile mental disorder such as dementia, quantity of excercise and amount of sunlight are important clue for dose and the treatment. Therefore, monitoring health information of daily life is necessary for patients' safety and healthy life. Portable & wearable sensor device and server configuration monitoring data are needed to provide these services for patients. Watch-type device(smart watch) which patients wear and server system are developed in this paper. Smart watch developed includes GPS, accelerometer and illumination sensor, and can obtain real time health information by measuring the position of patients, quantity of exercise and amount of sunlight. Server system includes the sensor data analysis algorithm and web server that doctor and protector can monitor through sensor data acquired from smart watch. The proposed data analysis algorithm acquires quantity of exercise information and detects step count in patients' motion acquired from acceleration sensor and to verify this, the three cases with fast pace, slow pace, and walking pace show 96% of the experimental result. If developed u-Healthcare System for dementia patients is applied, more high-quality medical service can be provided to patients.