• Title/Summary/Keyword: Weak ground

Search Result 367, Processing Time 0.024 seconds

Parameter estimation of weak space-based ADS-B signals using genetic algorithm

  • Tao, Feng;Jun, Liang
    • ETRI Journal
    • /
    • v.43 no.2
    • /
    • pp.324-331
    • /
    • 2021
  • Space-based automatic dependent surveillance-broadcast (ADS-B) is an important emerging augmentation of existing ground-based ADS-B systems. In this paper, the problem of space-based ultra-long-range reception processing of ADS-B signals is described. We first introduce a header detection method for accurately determining the pulse position of a weak ADS-B signal. We designed a signal encoding method, shaping method, and fitness function. We then employed a genetic algorithm to perform high-precision frequency and phase estimations of the detected weak signal. The advantage of this algorithm is that it can simultaneously estimate the frequency and phase, meaning a direct coherent demodulation can be implemented. To address the computational complexity of the genetic algorithm, we improved the ratio algorithm for frequency estimation and raised the accuracy beyond that of the original ratio algorithm with only a slight increase in the computational complexity using relatively few sampling points.

Design of Hairpin-Comb Bandpass Filter using Ground Aperture (접지면 어퍼쳐를 사용한 Hairpin-Comb 대역통과 여파기 설계)

  • 이진택;박정훈;김상태;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.20-26
    • /
    • 2003
  • This paper presents hairpin-comb bandpass filter using ground aperture. Hairpin-comb resonator maintains the weak coupling though the space between two resonators is very small. This has the good merit that the entire filter size is small for narrowband bandpass filter. The coupling between two hairpin-comb resonators so very weak that can't be applicable to general microstrip. We compensate the coupling by using ground aperture. It makes the hairpin-comb filter possible that can be applicable to general microstrip. Also it has the good merit which adjusts the bandwidth by changing the size of aperture without changing the space. In this paper, we fabricate the bandpass filter, which has 1.78 GHz center frequency and 62 MHz (3.5%) fractional bandwidth.

Prediction of ground-condition ahead of tunnel face using electromagnetic wave - analytical study (전자기파를 이용한 터널전방 예측 -해석기법 중심으로)

  • Choi, Jun-Su;Cho, Gye-Chun;Lee, Geun-Ha;Yoon, Ji-Nam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.327-343
    • /
    • 2004
  • During tunnel construction, ground failures often occur due to existence of weak zones, such as faults, joints, and cavities, ahead of tunnel face. It is hard to detect effectively weak zones, which can lead underground structure to fail after excavation and before supporting, by using conventional characterization methods. In this study, an enhanced analytical method of predicting weak zones ahead of tunnel face is developed to overcome some problems in the conventional geophysical exploration methods. The analytical method is based on Coulomb's and Gauss' laws with considering the characteristics of electric fields subjected to rock mass. Using the developed method, closed form solutions are obtained to detect a spherical shaped zone and an oriented fault ahead of tunnel face respectively. The analytical results suggest that the presence of weak zones and their sizes, location, and states can be accurately predicted by combining a proper inversion process with resistance measured from several electrodes on the tunnel face. It appears that the skin depth or resistivity in rock mass is affected by the diameter of tunnel face, natural electric potential and noises induced by experimental measurement and spatial distribution of uncertain properties. The developed analytical solution is verified through experimental tests. About 1800 concrete blocks of 5cm by 5cm by 5cm in size are prepared and used to model a joint rock mass around tunnel face. Weak zones are simulated ahead of tunnel face with a material which has relatively higher conductivity than concrete blocks. Experimental results on the model test show a good agreement with analytical results.

  • PDF

Structural Analysis of Stone Pagoda Structure considering Soft Soil Ground Characteristics (연약지반 특성을 고려한 석탑구조물의 구조해석)

  • Kim, Ho-Ryong;Shin, Hyo-Bum;Park, Young-Sin;Kang, Myoung-Hee;Hong, Souk-Il;Kim, Ho-Soo
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.70-73
    • /
    • 2008
  • Because the inclination and crack of stone pagoda structure are caused by the depth difference of soft soil ground and ground subsidence in weak zone, a long-term conservation of stone pagoda structure is difficult. But it is insufficient to analyze the behavior of stone pagoda structure considering soft soil ground in our country. Therefore, we find the structural effect happening in stone pagoda structure by analyzing mechanically a specific of soft soil ground and carry out structural analysis and structural modelling of stone pagoda structure that considers soft soil ground by discrete element method.

  • PDF

Design and Construction Case of Urban Tunnel in Alluvial Soil (충적토사지반에서의 도심터널 설계 및 시공)

  • Chang, Seok-Bue;Huh, Do-Hak;Moon, Sang-Jo;Kim, Do-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.829-834
    • /
    • 2009
  • Alluvial soil is one of the most difficult grounds for tunneling works due to the insufficient ground strength and excessive ground water inflow. Dduk island in Seoul has a wide alluvium developed by two rivers, Han and Jung-Ryang. Subway tunnel of $\bigcirc\bigcirc$ line planed across Dduk island has highly poor ground conditions due to small cover and deeply developed alluvium. Moreover, much part of this tunnel is located parallel to the bridge foundations of another railway with a small horizontal distance. Original design was done in 2002 and construction has been in progress. During the construction, tunnel design has been partly changed and adjusted for the complex ground condition and the demand from related organizations. This paper intend to introduce the urban tunnel design and construction in alluvial soils. This line could be divided three sections(A, B, C) according to ground and adjacent conditions. Section A is featured by mixed tunnel faces consisted with alluvial soils and weathered or weak rocks. The feature of section B is that tunnel underpasses near the bridge foundations of another subway. Lastly, section C with a very short length is the most difficult construction conditions due to the small cover, poor ground, obstacles on and underneath ground surface.

  • PDF

Physcial and Mechanical Characteristics of Soft Clay in Nam-Ak New City (남악신도시 연약점토의 물리적 특성 및 역학적 특성 연구)

  • 김종렬;배성웅;이치열
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.271-278
    • /
    • 2002
  • Soft ground has complex features in mechanic character of ground. Some problems about the settlement and transformation occur if the ground strength is comparatively weak and the depth is large. Therefore, we should consider physical and mechanical characters for safe, economical design and management. As the result of the course, we can compare them with those of field then solve the limitations which were came from the complex character of the soft ground. I have considered the soil's physical character (specific gravity of soil particles, moisture content, grain-size analysis etc) and mechanical character (direct shear test, consolidation, triaxial shear test etc), and then make out a linear interpolation by regression using the two, those and connection of the depth

  • PDF

Study on Physical Characteristics of Historical and Artificial Ground Accelration (역사지진 및 인공지진의 물리적특성에 관한 연구)

  • 전환석
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.52-57
    • /
    • 1998
  • Becaruse of the continual occurrence of minor and moderate earthquake in Korean peninsula, it is generally considered that Korean is nor located in safe region against probable earthquake and more, even though being recognized as a safe contry in earthquake. It is in particular noted that nowadays there has been much concern about undesirable disaster due to unexpected earthquake since the disaster of 1995 Kobe earthquake. Thus, the objective of this research is to develop appropriate design spectrum which could be practicably used in seismic design of important structures taking into consideration of local physical characteristics. Particularly, we have to keep in mind the lessons from 1985 Mexico earthquake which had disregarded deep research on local ground conditions, being a possible magnification phenomena of ground motions in weak soil layer. Various spectra has been described based on the analysis of historical earthquakes, and appropriate design spectrum has been proposed herein.

  • PDF

A study on analysis method for the prediction of changes in ground condition ahead of the tunnel face (터널 막장 전방의 지반 변화 예측을 위한 해석기법에 관한 연구)

  • Kim, Young-Sub;Kim, Chan-Dong;Jung, Yong-Chan;Lee, Jae-Sung;You, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.1
    • /
    • pp.71-83
    • /
    • 2004
  • The purpose of this study is to present an analysis method for the prediction of the changes m ground conditions. To this end, three dimensional convergence displacements are analyzed in several ways to estimate the trend of displacement changes. Three-dimensional arching effect is occurred around the unsupported excavation surface including tunnel face when a tunnel is excavated in a stable rock mass. If the ground condition ahead of tunnel face changes or a weak zone exists, a diagnostic trend of displacement change is observed by the 3 dimensional measurement and numerical analysis. Therefore, the change of ground condition and the existence of a weak zone ahead of tunnel face can be predicted by monitoring 3-dimensional absolute displacements during excavation, and applying the methodology (the ratio of L/C, $C/C_o$, etc.) presented in this study.

  • PDF

Influence of Weak Ground Ahead of the Tunnel Face on 3D-displacement and Face Extrusion (막장전방의 연약층이 터널 3차원변위 및 막장 수평변위에 미치는 영향)

  • Jeon, Je-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.189-206
    • /
    • 2003
  • During tunnel excavation in urban area a systematic monitoring is important for the purpose of determination of support type and quantity, as well as for the control of stability of both surface structures and the tunnel itself due to the frequently, and in many cases, abruptly changing ground condition. In Austria absolute displacement monitoring methods have replaced relative displacement measurements by geodetic methods to a large extent. Prompt detection of weak ground ahead of the tunnel face as well as better adjustment of excavation and support to the geotechnical conditions is possible with the help of the improved methods of data evaluation on sites. Deformation response of the ground to excavation starts ahead of the tunnel face, therefore, the deformation and state of the tunnel advance core is the key factor of the whole deformation process after excavation. In other words, the rigidity and state of the advance core play a determining role in the stability of both surface structures and the tunnel itself. This paper presents the results from detailed three-dimensional numerical studies, exploring vertical displacements, vector orientations and extrusions on tunnel face during the progressive advancement for the shallow tunnel in various geotechnical conditions.

Influence on Meridians Electric Potential for Electrical Ground and Insulation (-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.