• 제목/요약/키워드: Wavelength reference

검색결과 127건 처리시간 0.022초

Encrypted holographic storage using double-phase encoding technique

  • Vu, Tien-Viet;Kim, Nam;Jeon, Seok-Hui
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.229-230
    • /
    • 2007
  • Several encryption techniques were successfully applied to secure holographic memory systems.[1,2] In these systems the reference beam, object beam, or both can be encoded optically. Optics provides many degrees of freedom with which the optical beam may be encoded, such as amplitude, phase, wavelength, and polarization.

  • PDF

Planar Waveguide Amplifiers

  • Berneschi, S.;Conti, G. Nunzi;Righini, G.C.
    • 세라미스트
    • /
    • 제10권3호
    • /
    • pp.75-85
    • /
    • 2007
  • Over the past few years, due to the great development of optical communications, an increasing R&D activity has been focused on the design and manufacture of the integrated optic amplifiers, with particular reference to their application in wavelength-division-multiplexing (WDM) systems. In this technological context, rare-earth-doped oxide glasses, which had been widely used for solid state lasers, gained much attention as highly performing materials in the third telecom window, around 1.5 micron. The aim of the present paper is to provide a brief overview of the progress made, with particular reference to the authors' work in this area, and to shortly discuss its perspectives.

  • PDF

THE EFFECT OF ATMOSPHERIC SCATTERING AS INFERRED FROM THE ROCKET-BORNE UV RADIOMETER MEASUREMENTS

  • Kim, Jhoon
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권1호
    • /
    • pp.87-93
    • /
    • 1997
  • Radiometers in UV and visible wavelengths were onboard the Korean Sounding Rocket(KSR)-1 and 2 which were launched on June 4th and September 1st, 1993. These radiometers were designed to capture the solar radiation during the ascending period of the rocket flight. The purpose of the instrument was to measure the vertical profiles of stratospheric ozone densities. Since the instrument measured the solar radiation from the ground to its apogee, it is possible to investigate the altitude variation of the measured intensity and to estimate the effect of atmospheric scattering by comparing the UV and visible intensity. The visible channel was a reference because the 450-nm wavelength is in the atmospheric window region, where the solar radiation is transmitted through the atmosphere without being absorbed by other atmospheric gases. The use of 450-nm channel intensity as a reference should be limited to the altitude ranges above the certain altitudes, say 20 to 25km where the signals are not perturbed by atmospheric scattering effects.

  • PDF

Improved Free-air Gravity Anomalies by Satellite Altimetry

  • Kim, Jeong-Woo;Roman, Daniel-R.
    • 대한원격탐사학회지
    • /
    • 제17권4호
    • /
    • pp.297-305
    • /
    • 2001
  • Ocean satellite altimetry-implied free-air gravity anomalies have had the shortest wavelengths removed during the processing to generate the optimal solution between multiple radar altimeter missions. ERS-1 168day mission altimetry was residualized to a reference geoid surface generated by integrating Anderson & Knudsen’s free-air gravity anomalies for the Barents Sea. The altimetry tracks were reduced and filtered to extract the shortest wavelengths (between 4 and 111 km) from both ascending and descending tracks, respectively. These data were recombined using existing quadrant-swapping techniques in the wavenumber domain to generate a correlated, high frequency gravity field related to the local geologic sources. This added-value surface adjusted the reference free-air gravity anomalies to better reflect features in the gravity field at a wavelength related to the distance between altimetry ground tracks.

Mass Balance Method for Purity Assessment of Organic Reference Materials: for Thermolabile Materials with LC-UV Method

  • Lee, Joonhee;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권11호
    • /
    • pp.3275-3279
    • /
    • 2014
  • A mass balance method for purity assessment of thermolabile organic reference materials was established by combining several techniques, including liquid chromatography with UV/VIS detector (LC-UV), Karl-Fischer (K-F) Coulometry, and thermal gravimetric analysis (TGA). This method was applied to three fluoroquinolones like enrofloxacin, norfloxacin and ciprofloxacin. LC-UV was used to analyze structurally related organic impurities based on UV/VIS absorbance spectra obtained in combination with LC separation. For all three organic reference materials, the UV/VIS spectra of the separated impurities were similar to that of the major component of the corresponding materials. This indicates that the impurities are structurally related to the respective reference material sharing common chromophores. Impurities could be quantified by comparing their absorbances at the wavelength of maximum absorbance (${\lambda}_{max}$). The water contents of the reference materials were measured by K-F Coulometry by an oven-drying method. The total inorganic impurities contents were assayed from ash residues in TGA analysis with using air as a reagent gas. The final purities estimated from results of those analytical techniques were assigned as ($99.91{\pm}0.06$), ($97.09{\pm}0.17$) and ($91.85{\pm}0.17$)% (kg/kg) for enrofloxacin, norfloxacin and ciprofloxacin, respectively. The assigned final purities would be applied to the reference materials which will be used as calibrators for the certification of those compounds in matrix CRMs as starting points for the traceability of their certified values to SI units.

해수의 광학적 성질에 관한 연구 - 일본 동경만 입구 ( 2 ) - (Optical Properties of Sea Water - Entrance of Tokyo Bay , Japan ( 2 ) -)

  • 양용림
    • 수산해양기술연구
    • /
    • 제22권2호
    • /
    • pp.16-21
    • /
    • 1986
  • Optical properties of sea water were studied in the entrance of Tokyo Bay, Japan. based on the data obtained from seven oceanographic stations in June. 1985. The observation of surface irradiance and underwater irradiance of sea water for eight kind of wavelength (378, 422, 481, 513, 570, 621, 653. 677nm) of sun light was conducted using the underwater irradiameter (Isigawa # SR-8). The mean att;enuation coefficient of the sea water was appeared to be 0.245 (0.042-0.776) and the attenuation co~fficient of the sea water for wavelength appeared such as 0.227 for 378 nm, 0.186 for 422 nm. O. 175 for 481 nm. O. 176 for 513 nm. O. 185 for 570 nm, 0.337 for 621 nm. O. 321 for 653 nm, O. 348 for 677 nm. The transparency was 7.0 m (5.5-9 m). water color was 10 (8.0-13.0) in the study area and the sun altitude was 60.95$^{\circ}$ (43.610-75.500). The relationship between attenuation coefficient (K) and transparency (D) was K = 2.63/ D (1.28/ D- 4. 87/D). The rate of light penetration for eight kind of wave Ie nth (378, 422. 481. 513. 570, 621, 653, 677 nm) were computed with reference to the surface light intensity respectively. The mean rate of light penetration in proportion to depths were 68.63% (46.02-86.07%) in 1 m layer, 18.40% (2.07 -48.48%) in 5m layer, 4.82% (0.042-22.30%) in 10m layer and 1.35% (0.01I-7.42%) in 20m layer. The rate of light penetration at the transparency layer with reference to the surface light intensity was shown as 10.39% (0.77-27.46%).

  • PDF

Absorption Spectroscopy of Biological Specimens Near X-ray Absorption Edges of Constituent Elements

  • Ito, Atsushi;Shinohara, Kunio
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.460-462
    • /
    • 2002
  • Absorption spectra of biological specimens in the soft X-ray region have been presented with special reference to the XANES (X-ray absorption Near Edge Structure) of constituent elements. Absorption spectrum in this wavelength region is characterized by the absorption edges from which elemental content could be derived. In addition, XANES has a characteristic profile for chemical environment around the element such as chemical bond. Using the specific absorption peak we can assign not only the chemical bond but also molecules having such a chemical bond. In the present paper, absorption spectrum of DNA was measured in the wavelength range from 1.5nm to 5nm. Spectrum of Chinese Hamster Ovary (CHO) cells was compared with the DNA spectrum. XANES were distinct at the K absorption edges of major elements, C, N and O. In the spectrum of the cells prominent peaks at the L absorption edge of minor element Ca were also detectable. XANES profiles in small local areas in a cell could also be measured in combination with X-ray microscopy. These give information about local chemical environment in a cell. XANES at the phosphorus K absorption edge in a human HeLa cell was successfully obtained corresponding to a sharp and intensive XANES peak of DNA.

  • PDF

어븀 첨가 광섬유의 첨가 농도에 따른 광유도 굴절률 및 분산의 변화 (Light-induced changes of refractive indices and dispersions of $Er^{3+}$-doped fibers of various doping concentrations)

  • 강승범
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.47-52
    • /
    • 1999
  • 두 개의 짧은 광경로가 밀착된 마하젠더 간섭계를 사용한 보다 간단하고 효율적인 시럼방법을 통하여 펌프광에 의해 유도되는 어븀 첨가 광섬유의 굴절률 변화와 분산특성을 측정하엿으며, 어븀 첨가 농도와 펌프광 세기에 이들 값들의 변화 특성을 규명하였다. 어븀 이옹의 첨가 농도가 300ppm에서 700ppm으로 증가할 때 1510∼1560nm의 파장 범위에서 1530 nm 의 공명파장 전후로 광유도된 굴절률과 분산의 변화량은 거의 선형적으로 증가하며 펌프광의 세기가 커질수록 변화량들은 증가하다가 전자들이 전부 여기됨과 동시에 점차 포화되는 것을 알 수 있었다.

  • PDF

더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발 (Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis)

  • 이준석;신대정;형기우;류인재
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

Comb-spacing-swept Source Using Differential Polarization Delay Line for Interferometric 3-dimensional Imaging

  • Park, Sang Min;Park, So Young;Kim, Chang-Seok
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.16-21
    • /
    • 2019
  • We present a broad-bandwidth comb-spacing-swept source (CSWS) based on a differential polarization delay line (DPDL) for interferometric three-dimensional (3D) imaging. The comb spacing of the CSWS is repeatedly swept by the tunable DPDL in the multiwavelength source to provide depth-scanning optical coherence tomography (OCT). As the polarization differential delay of the DPDL is tuned from 5 to 15 ps, the comb spacing along the wavelength continuously varies from 1.6 to 0.53 nm, respectively. The wavelength range of various semiconductor optical amplifiers and the cavity feedback ratio of the tunable fiber coupler are experimentally selected to obtain optimal conditions for a broader 3-dB bandwidth of the multiwavelength spectrum and thus provide a higher axial resolution of $35{\mu}m$ in interferometric OCT imaging. The proposed CSWS-OCT has a simple imaging interferometer configuration without reference-path scanning and a simple imaging process without the complex Fourier transform. 3D surface images of a via-hole structure on a printed circuit board and the top surface of a coin were acquired.