• 제목/요약/키워드: Wavelength monitoring

검색결과 210건 처리시간 0.02초

KaVA and EAVN large program on two Supermassive Black Holes, Sgr A∗ and M87

  • Sohn, Bong Won;Kino, Motoki
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.52.1-52.1
    • /
    • 2019
  • Exploring the vicinity of super-massive black holes (SMBHs) is one of the frontiers in astrophysics. KaVA AGN Science WG has launched its Large Program in 2014 focusing on two SMBHs, Sgr A∗ and M87. They are selected based on their large apparent size. Sgr A∗ is the excellent laboratory for studying gas accretion process onto SMBH and M87 is well known as the best case for investigating plasma outflow ultimately driven by SMBH. For Sgr A∗, KaVA and EAVN provides superb UV-coverage on its emitting region and its scattering medium. In the case of M87, we have conducted high cadence dual-frequency (22and 43GHz )VLBI monitoring to clarify the global profile of the M87 jet velocity field and the spectral index map, which should reflect global structure of magnetic fields in the jet. From 2017, the AGN LP is recognized as multi-wavelength EHT project, conducting quasi-simultaneous coherent observations of M87 and Sgr A∗ with the Event Horizon Telescope (EHT) during its campaign observation periods. AGN WG is reviewing and revising its LP to convert it to EAVN LP. We will briefly report our scientific results and future plan which includes even broader international collaboration, namely East-Asia to Italy Nearly Global (EATING) VLBI to reach higher angular resolution.

  • PDF

Standard Calibration for Broadband and Narrowband Filters of KHAO 0.4 m Telescope

  • Ahn, Hojae;Jeong, Inhwan;Paek, Gregory S.H.;Lee, Sumin;Kim, Changgon;Pak, Soojong;Shim, Hyunjin;Im, Myungshin
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.76.1-76.1
    • /
    • 2021
  • Maemi Dual Field Telescope System (MDFTS) is a dual telescope system located at Kyung Hee University. The system consists of 0.4 m telescope and 0.1 m telescope for wide-field observation. The 0.4 m telescope provides photometric observation which covers a field of view of 21'×16'. It has been used for various purposes with Johnson-Cousins UBVRI broadband filter system, e.g., SomangNet and Intensive Monitoring Survey of Nearby Galaxies. In this poster, we present the standard calibration result for our broadband filter system. Also, we suggest a new usage of the KHAO 0.4m telescope which is narrowband photometry by demonstrating the standard calibration of H-alpha filter. For flux calibration, not only R filter but also V filter is used for compensating the central wavelength discrepancy between R filter and H-alpha filter.

  • PDF

장기 모니터링 환경에서 센서 패키징 방법에 따른 광섬유 센서의 신호 안정성 평가 (Evaluation of Signal Stability of Fiber Optic Sensors with respect to Sensor Packaging Methods in Long-Term Monitoring)

  • 강동훈;김헌영;김대현
    • 비파괴검사학회지
    • /
    • 제36권4호
    • /
    • pp.281-287
    • /
    • 2016
  • 다중화와 절대측정이 가능한 광섬유 브래그 격자(FBG) 센서는 다양한 분야의 건전성 모니터링에 활용되고 있으며, 패키징을 통한 빠른 상용화가 진행 중이다. 하지만, 장시간 구조 건전성 모니터링시 FBG 센서는 반복 열하중에 노출되며 이는 센서의 신호 안정성에 영향을 줄 수 있어 면밀한 검토가 필요하다. 본 연구에서는 일반적으로 사용되는 FBG 센서의 브래그 격자 부분에 대한 두 가지 패키징 방법(양단 접착, 직접 접착)에 대해 반복 열하중이 신호 안정성에 미치는 영향을 고찰하였다. 구체적으로, $-20^{\circ}C{\sim}60^{\circ}C$의 온도 조건에서 300사이클 동안 FBG 센서의 브래그 파장, 광 강도값, 반너비값 등의 신호 특성을 관찰하였으며 직접 접착에 대해 수행한 선행 연구와의 비교를 통해 두 가지 패키징 방법에 대한 신호 안정성을 평가하였다. 시험 결과, 장기간 반복 열하중이 가해지는 환경에 노출된 FBG 센서의 경우 양단 접착이 직접 접착보다 신호 안정성이 더 높기 때문에 FBG 센서의 패키징시 양단 접착 방식이 더 효과적임을 확인하였다.

주차장관리 시스템 기지국용 소형 λ/4 폴디드 마이크로스트립 안테나 (Miniaturized λ/4 Folded Microstrip Antenna for Parking Monitoring Base Station System)

  • 금재민;고동옥;정재엽;우종명
    • 한국ITS학회 논문지
    • /
    • 제15권2호
    • /
    • pp.95-101
    • /
    • 2016
  • 본 논문에서는 주차장관리 시스템 기지국용 소형 ${\lambda}/4$ 폴디드 마이크로스트립 안테나를 제안, 설계 및 제작하였다. 제안된 안테나를 소형화하기 위해 먼저 기준 ${\lambda}/2$ 마이크로스트립 패치 안테나에서 방사소자 폭을 줄이고, 다음은 방사소자 길이를 줄여주기 위하여 섭동효과(Perturbation effect)를 이용하여 개구면에 폴디드 구조를 적용하였다. 끝으로 ${\lambda}/2$ 길이의 폴디드 마이크로스트립 안테나를 ${\lambda}/4$ 폴디드 마이크로스트립 안테나로 더욱 소형화시켰다. 설계된 안테나는 중심주파수 425 MHz에서 크기는 $134mm{\times}143.85mm{\times}20.1mm$($0.19{\lambda}{\times}0.2{\lambda}{\times}0.028{\lambda}$, ${\lambda}$는 425 MHz의 한 파장 길이)로 기본 마이크로스트립 패치 안테나와 비교하여 97.2% 소형화 되었다. 또한 -10 dB 대역폭은 2.44 MHz(0.57%)로 측정되었으며 방사패턴은 E-plane $15^{\circ}$에서 최대 1.82 dBi의 이득을 얻었다.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

광섬유 FBG 센서의 시간 분할 다중화를 위한 반사 신호의 분석 (Reflection Signal Analysis for Time Division Multiplexing of Fiber Optic FBG Sensors)

  • 김근진;권일범;윤동진;황두선;정영주
    • 비파괴검사학회지
    • /
    • 제30권1호
    • /
    • pp.6-12
    • /
    • 2010
  • 대형 구조물의 넓은 영역에 분포된 변형률이나 온도를 모니터링하기 위하여 광섬유 FBG(fiber Bragg grating:브래그 격자) 탐촉자를 사용하는 광섬유 FBG 센서가 사용된다. 본 논문에서는 광섬유 한개의 라인에 다수의 FBG 탐촉자를 사용하기 위하여 시간 분할 다중화와 파장 분할 다중화를 복합화한 다중화 기술을 제안한다. 일반적으로 광섬유 FBG 센서는 기본적으로 파장 분할 다중화 방식으로 작동되므로 본 연구에서는 시간 분할 다중화에 대한 특성을 고찰한다. 광섬유에 직렬로 연결된 FBG 탐촉자들의 반사도에 따른 반사광의 세기와 그 위치를 이론적으로 계산하고 실험결과와 비교한다. 이론적인 계산에 따르면 5개의 FBG 탐촉자의 반사도를 적절하게 선정함에 의하여 한개의 광섬유 라인에 설치하여 각각의 FBG 탐촉자에서 되돌아오는 반사광의 세기를 균일하게 얻을 수 있음을 확인한다. 이러한 결과를 실험으로 확인하기 위하여 반사도가 13%, 16%, 25%, 40%, 80%인 FBG 탐촉자를 제작하고, 시간 영역에서 각각의 FBG 탐촉자에서 되돌아오는 반사 신호를 관찰한다. 실험 결과는 신호잡음의 영향으로 이론적인 결과와 차이가 있지만, 복합 다중화 기법의 사용 가능성을 증명하는 5개의 FBG 탐촉자의 반사 신호를 모두 보인다.

기계학습모형을 이용한 다분광 위성 영상 기반 낙동강 부유 물질 농도 계측 기법 개발 (Development of suspended solid concentration measurement technique based on multi-spectral satellite imagery in Nakdong River using machine learning model)

  • 권시윤;서일원;백동해
    • 한국수자원학회논문집
    • /
    • 제54권2호
    • /
    • pp.121-133
    • /
    • 2021
  • 하천에서 발생하는 부유 물질은 주로 유역으로부터 유입되거나 하천 내에서 자생으로 발생하기도 하며, 퇴적되어 중장기적인 수질 오염을 초래할 수도 있는 중요한 수질 인자이다. 하지만, 부유물질의 재래식 계측방식은 점 단위 계측이기 때문에 노동 집약적이며 방대한 양의 자료를 취득하기는 어렵다. 따라서, 본 연구에서는 고해상도 다분광 위성영상을 제공하는 Sentinel-2 위성 자료를 이용하여 낙동강 전역에 대한 원격탐사 기반 부유 물질 농도 계측 기법을 개발하였다. 개발된 기법은 기존 원격탐사 기반 회귀식들의 한계점을 개선하고 낙동강 전체 영역의 지역적 특성을 반영하기 위해 기계학습 모형인 서포트 벡터 회귀(Support Vector Regression, SVR) 모형을 이용하여 다양한 파장대의 분광 밴드들과 밴드비(band ratios)를 고려하였으며, 이를 입력 변수들의 최적 조합으로 재귀적 특징 제거법(Recursive Feature Elimination, RFE)과 SVR의 각 변수별 가중계수를 활용하여 도출하였다. 가장 중요도가 높은 분광 밴드로는 Red-edge 파장대 영역에 속하는 705 nm 밴드가 산출되었으며, 최종적으로 구축된 SVR 모형을 선행 연구들에서 제시한 회귀식들과 비교한 결과, 가장 정확한 계측 결과를 제공하는 것으로 밝혀졌다. 본 연구에서 개발된 SVR 모형은 RFE를 통해 산출된 최적 분광 밴드 조합을 바탕으로 하기 때문에 기존 단일 분광 밴드 혹은 밴드비를 기반으로 구축된 회귀식들이 가지는 변수 의존도를 낮추는 동시에 더욱 정확한 부유물질 농도 공간분포를 제공할 수 있을 것으로 판단된다.

Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술 (Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS))

  • 박진영;김현아;박기홍;김경웅
    • 자원환경지질
    • /
    • 제50권5호
    • /
    • pp.341-352
    • /
    • 2017
  • Cs-137 (반감기 : 30.17년)과 더불어 중요한 원자력발전소 주변 환경감시대상 방사성 핵종 가운데 하나인 순수한 베타방출체인 Sr-90 (반감기 : 28.8년)에 대한 신속하고 용이한 모니터링 방법을 연구하였다. 스트론튬은 칼슘과 같은 2족 알칼리 토금속에 속해 있어서 전자배치나 크기가 비슷하며 최외각전자를 2개 가지고 있기 때문에 화학적으로 칼슘과 치환될 수 있다. 이러한 유사한 화학적 성질로 인해서 환경으로 유출시 물, 토양 및 농작물을 통한 먹이사슬을 거쳐서 인체로 쉽게 유입될 수 있으며, 인체 유입 시 뼈에 쉽게 침적되어 장기간 (생물학적 반감기 : 약 50년) 동안 독성을 유발한다. 스트론튬은 매우 환원성이 있고 특이 반응으로 습식분석이 어려우며, 특히 원자력발전소에서 감시하고 있는 방사성 스트론튬은 복잡한 분석절차, 고가의 분석 장비 사용 및 화학 전처리약품 다량 사용 등으로 분석의 정확도 저하는 물론 고비용에 따른 문제를 안고 있다. 따라서 펄스에너지를 사용하여 시료에 플라즈마를 생성시켜 고유 스펙트럼을 이용해 시료내 원소를 분석하는 Laser-Induced Breakdown Spectroscopy (LIBS) 분석기법을 도입하여 전처리 과정 없이 수 초 내에 분석이 가능하고 현장에서 실시간으로 측정 가능한 스트론튬 원소의 정량분석 방법을 도출하였다. 다양한 분석에 필요한 시료기판을 개발하여 레이저, 파장 및 시간분해능의 최적화로 분석 감도를 향상시키고 방해이온에 대한 영향 평가로 액체시료의 정량분석을 가능하게 하여 신속한 모니터링 체계를 구축하게 하였다. 이는 원자력발전소로부터 방출되고 있는 방사성 폐수의 실시간 모니터링에 효과적으로 적용될 수 있으며, 더 나아가 후쿠시마 원전사고와 같은 비상시 모니터링 수단으로 적용 될 수 있다.

7-안테나로 구성된 원형배열 상관형 위상비교 방향탐지의 데이터 융합 (Data Convergence of circular Array Correlative Interferometer Direction Finding with 7-Antenna)

  • 임중수
    • 한국융합학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 2017
  • 본 논문은 7개 안테나로 구성된 원형배열 안테나에 전파가 입사될 때 안테나 상호간의 계산 위상차와 시험 환경에서 측정한 위상차를 데이터 융합하여 전파의 도래 방향을 탐지하는 상관형(correlative) 위상비교 방향탐지에 대하여 기술하였다. 상관형 위상비교 방식은 균일원형배열(UCA: uniform circular array)과 선형 배열 방식이 많이 사용되며, 수식적으로 계산한 위상차 데이터와 시험 환경에서 측정한 위상차 데이터를 상관함수로 데이터 융합하여 전파 입사 방위각을 계산하므로 현재 많이 사용되고 있는 측정위상차비교 방향탐지 방식보다 성능이 우수하다. 수신신호의 신호잡음비(SNR)가 20dB이고 수신신호의 파장에 대한 안테나 상호간 거리($L/{\lambda}$)가 0.5인 경우 상관형 방탐은 방향탐지 정확도가 $1.7^{\circ}$ 로 나타나서 측정형 위상비교인 경우 $2.5^{\circ}$ 이상인 것과 비교하여 우수한 것이 확인되었으며 전자파신호 감시용, 군사용 방향탐지용에 사용될 수 있을 것으로 판단된다.

Seyfert 1 은하 NGC 4151, NGC 5548의 BLR 밀도 변화 (BLR Density Variations of the Seyfert 1 Galaxies NGC 4151 and NGC 5548)

  • 손동훈;형식
    • 한국지구과학회지
    • /
    • 제25권6호
    • /
    • pp.495-501
    • /
    • 2004
  • AGN(Active Galactic Nuclei)의 핵과 BLR(Broad Line Region) 영역의 변광 연구를 위해, 밝은 Seyfert 1 은하들에 대한 밝기 변화 감시 캠페인들이 있었다. 이러한 노력은 주로 지상 관측과 IUE 관측을 통해서 이루어졌으며, 가시광에서 감마선까지 모든 파장영역의 동시 관측도 시도되었다. 우리는 IUE를 이용한 주요 모니터링 대상이었던 NGC 4151과 NGC 5548에 대한 관측자료를 정리하여, 이들 중 SWP(Short Wavelength Prime), 저분산, 대구경 슬릿, 분광 관측 자료들을 분석하였다. Si III] 1892와 C III] 1909의 플럭스비를 통해 BLR의 전자 밀도를 구하였고, C IV 1550 와 C III] 1909 비를 통해 BLR의 온도와 이온호 정도를 가늠하였다. NGC 4151과 NGC 5548의 밀도 변화 폭은 각각 4배, 8배 정도로 작은 변화만을 보여주었다. 이들의 변화를 조사하여 BLR의 물리적 조건과 블랙홀 주위 활동성과 기하학적 특성 파악을 시도하였다. BLR 크기와 C III] 선폭으로부터 구한 중심 블랙홀의 질량은 모두 107 $M_{\odot}$ 정도로 추정된다.