• 제목/요약/키워드: Waveform distortion

검색결과 196건 처리시간 0.04초

Comparison of the harmonic reduction by using harmonic passive fitters and technique of intervene firing method at the pulse of the 6-pulse phase controlled converter.

  • Wongtongdee, Surached W.;Laohasongkram, Pipat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.782-785
    • /
    • 2005
  • This article introduces technique to reduce harmonic by using the $5^{th}$ and $7^{th}$ harmonic tune filter and line reactor in the comparison to the technique of intervening firing method at the pulse of the 6-pulse phase-controlled converter in every 1/6 period. The design of the technique introduced in this article is to reduce the harmonic distortion of the current and the voltage resulted from three-phase thyristor phase-controlled converter. The waveform obtained from the experiment was analyzed on the spectrum of the current, voltage and the total harmonic distortion. The double firing method causes zero vectors of output voltage and input current. Designing the mechanism of the converter based on the idea of Park Vector Theory, the number of harmonic distortion in the intervening firing method were compared to those in normal firing method.

  • PDF

부스트컨버터의 고조파저감을 위한 스위칭 기법에 관한 연구 (A study On the Switching Technique of Boost Converter for Harmonic Reduction)

  • 손진근;추순남;김용혁;이상철;이복용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.74-78
    • /
    • 2000
  • In this paper a switching control circuit for shaping the line current and reducing the total harmonics distortion in the boost converter is presented. To solve the problems of performance degradation due to pulse waveform in the input current, the boost converter in which the harmonic distortion in the input current is reduced using a 3th harmonic-injected PWM is proposed. Finally, Simulation and experimental results of boost converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석 (Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog)

  • 박재준;양태규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.500-504
    • /
    • 2004
  • 본 연구에서는 EPDM 고분자애자의 염무량 변화(salt:l0g, 25g, 50g, deionized water: 1000g)에 따른 표면방전과 환경적인 변화(salt fog 및 clean fog 그리고 raim)에 대한 누설전류 파형의 결과를 알아보았다. 기본파 및 3고조파 그리고 5고조파의 변화양상을 과전초기로부터 섬락시에 이르기까지 나타내었다. 표면열화의 진단기법을 개발하기위해서 누설전류파형의 주파수 스펙트럼을 이용하였고, 고분자애자의 표면열화에대한 환경적인 영향(clean fog, salt fog, rain)을 연구 하였다. 염분량의 변화시 기본파에 대한 저주파 고조파인 3고조파 및 5고조파에 대한 백분율(왜곡도)의 변화를 이용하여 표면 열화상태 및 정도를 정량화(a standard capacity)하여 나타내었다. 기본파에 대한 고조파 백분율인 왜곡율은 고분자 애자의 표면조건을 평가하는데 필요한 지시자라는 사실을 알 수 있었다.

  • PDF

고음질 합성방식용 V/UV 스펙트럼상의 피치변경법에 관한 연구 (On a Pitch Alteration Technique in the V/UV Spectrum for High Quality Speech Synthesis Technique)

  • 조왕래;배명진;김동성
    • 한국음향학회지
    • /
    • 제15권6호
    • /
    • pp.99-103
    • /
    • 1996
  • 파형부호화법은 파형의 잉여성분 제거과정을 통해 음성파형의 꼴을 단순히 보존하는 부호화법이다. 음성합성분야에서 파형부호화법은 주로 분석에 의한 고음질 합성방식으로 적용되고 있다. 그렇지만 이 부호화법은 분석시에 여기원과 성도여파기 피라미터들로 분류하여 처리하지 않기 때문에 규칙에 의한 합성방식으로는 적용하기가 힘들다. 본 논문에서는 스펙트럼영역에서 유성스펙트럼에 대해서만 스펙트럼축의 변경을 통해 피치를 조절하는 새로운 피치변경법을 제안하였다. 이 방법은 주파수영역의 처리법이며 50%의 피치변경을 수행하여도 스펙트럼 왜곡율이 2.7% 이하로 얻어졌고, 시간영역의 위상특성 보상에 의해 프레임간의 진폭연결이 자연스럽다는 장점을 갖느다.

  • PDF

임의 파형 발생기를 위한 단일 루프 전압 제어기 설계 (Design of the Single-loop Voltage Controller for Arbitrary Waveform Generator)

  • 김현식;지승준;설승기
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.58-64
    • /
    • 2016
  • This study presents a design method for a single-loop voltage controller that is suitable for an arbitrary waveform generator (AWG). The voltage control algorithm of AWG should ensure high dynamic performance and should attain sufficient robustness to disturbances such as inverter nonlinearity, sensor noise, and load current. By analyzing the power circuit of AWG, control limitation and control target are presented to improve the dynamic performance of AWG. The proposed voltage control algorithm is composed of a single-loop output voltage control, an inverter current feedback term to improve transient response, and a load current feedforward term to prevent voltage distortion. The guideline for setting control gain is presented based on output filter parameters and digital time delay. The performance of the proposed algorithm is proven by experimental results through comparison with the conventional algorithm.

컨트롤 차트를 이용한 고조파 전압 왜곡 발생원 관리기법 연구 (Study of Harmonic Sources Management Method using Control Chart)

  • 한종훈;이계병;장길수;박창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.197-198
    • /
    • 2011
  • A technique to manage harmonic pollution at the point of common coupling (PCC) has been presented using a control chart. The recursive least-squares technique has been used to estimate the parameters of the Thevenin equivalent load model. With the estimated data from the measured voltage and current waveform at the PCC during certain period violating upper control limit, the individual contributions to the distortion of voltage waveform at an interested harmonic frequency have been calculated and shown by simple graph.

  • PDF

양방향 부분공진 소프트 스위칭을 적용한 AC-DC컨버터의 설계 (A Design of AC-DC Converter using Bi-directional Partial Resonant Soft-Switching)

  • 윤상훈;고강훈;서기영;권순걸;이현우;이철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1023-1025
    • /
    • 2001
  • This paper proposes a bi-directional current switch with snubber regeneration using Power MOSFETs and this paper proposes to use a loss-less snubber with switching device to perform soft-switching. It results in not only decreasing switching loss in the device drastically, but also improving input ac current waveform distortion. The computer simulation results show that the input current waveform and show the requirements necessary for the elimination of the 3rd harmonic component. We also show the procedure to design the parameters of the converter.

  • PDF

정현파 입력 역률개선을 위한 단상 강압형 AC-DC 컨버터 (Sinusoidal Input Power factor Improved for Single-Phase Buck AC-DC Type Converter)

  • 정상화;권순걸;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.338-340
    • /
    • 2001
  • Power factor improved for single-phase buck-converter is studied in the paper. To sinusoidal waveform the input current with a near-unity power factor over a wide variety of operating conditions, the output capacitor is operated with voltage reversibility for the supply by arranging the auxiliary diode and power switching device. Then the output voltage is superposed on the input voltage during on time duration of power switching devices in order to minimize the input current distortion caused by the small input voltage when changing the polarity. The tested setup, using two insulated gate bipolar transistors(IGBT) and a microcomputer, is implemented and IGBT are switched with 20[kHz], which is out of the audible band. Moreover, a rigorous state-space analysis is introduced to predict the operation of the rectifier. The simulated results confirm that the input current can be sinusoidal waveform with a near-unity power factor and a satisfactory output voltage regulation can be achieved.

  • PDF

Fuzzy Syntactic Pattern Recognition Approach for Extracting and Classifying Flaw Patterns from and Eddy-Current Signal Waveform

  • Kang, Soon-Ju
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권4호
    • /
    • pp.59-65
    • /
    • 1997
  • In this paper, a general fuzzy syntactic method for recognition of flaw patterns and for the measurement of flaw characteristic parameters for a non-destructive inspections signal, called eddy-current, is presented. Solutions are given to the subtasks of primitive pattern selection, signal to symbol transformation, pattern grammar formulation, and event-synchronous flaw pattern extraction based on the grammars. Fuzzy attribute grammars are used as the model for the pattern grammar because of their descriptive power in the face of uncertain constraints caused by nose or distortion in the signal waveform, due to their ability to handle syntactic as well as semantic information. This approach has been implemented and the performance of eh resultant system has been evaluated using a library of law patterns obtained from steam generator tubes in nuclear power plants by an eddy current-based non-destructive inspection method.

  • PDF

PWM 인버터의 전류파형 개선에 관한 연구 (Current Waveform Improvement of PWM Inverter)

  • 장석주;조상환;설승기
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.273-280
    • /
    • 1990
  • To prevent the shoot-through phenomena in a PWM inverter, a short dead time is usually provided between a pair of switching transistors in the same leg of the inverter. In this approach, the amount of the dead time is designed to meet the worst case condition of the inverter transistors and the base drive elements. So, in normal cases, relatively large portion of the dead time is unnecessary and it results in an undesirablecurrent waveform distortion and generates ripple torque on the motor shaft. In this paper, a new base drive method to remove the undesirable portion of the dead time is described. The method senses the transistor on/off states to interlock the other transistor of the leg without the external dead time. Also, for the transistors of large current rating, the Darlington drive circuit is combined to the proposed method and is tested to verify the effectiveness. The experimental results of the proposed method are described and compared with those of the conventional dead time method.