• Title/Summary/Keyword: Wave parameters

Search Result 1,594, Processing Time 0.029 seconds

Assessment of Right Ventricular Function in Patients with Chronic Obstructive Pulmonary Disease Using Echocardiographic Tei Index (만성 폐쇄성 폐질환 환자에서 Tei 지수를 이용한 우심실기능 평가)

  • Oh, Yoon-Jung;Shin, Joon-Han;Kim, Deog-Ki;Choi, Young-Hwa;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.343-352
    • /
    • 2001
  • Background : Advanced chronic obstructive pulmonary disease is characterized by progressive pulmonary hypertension leading to right heart dysfunction, which plays a Important role in clinical evaluation but remains difficult and challenging to quantify. The noninvasive doppler echocardiographic value referred to as the Tei index has been suggested as a simple, reproducible and reliable parameter of the right ventricular function. The purpose of this was to assess the right ventricular function in patients with chronic obstructive pulmonary disease using the Tei index and to evaluate its relationship with the pulmonary functional status. Methods : The study population comprised of 26 patients with chronic obstructive pulmonary disease and 10 normal control subjects. The Tei index was obtained by dividing the sum of the isovolumetric contraction and the relaxation times by the ejection time using a pulsed-wave doppler. It was compared with the other available Doppler echocardiographic parameters of systolic or diastolic function and with the pulmonary function of the patients. Results : The Tei indices of the patients with COPD were significantly higher than those of normal subjects($0.45{\pm}0.17$ vs. $0.27{\pm}0.03$, p<0.01). The isovolumetric contraction time/ejection time($0.32{\pm}0.08$ vs. $0.25{\pm}0.05$, p<0.05), the isovolumetric relaxation time/ejection time($0.29{\pm}0.16$ vs. $0.15{\pm}0.08$, p<0.05)and the preejection period/ejection time ($0.46{\pm}0.10$ vs. $0.38{\pm}0.06$, p<0.05) were prolonged and the ejection time ($255.2{\pm}32.6$ vs. $314.2{\pm}16.5$ msec, p<0.05) was significantly shortened in patients with COPD compared to normal subjects. The tei indices were inversely correlated with the $FEV_1$ (r=-0.46, p<0.05) and were prolonged significantly in patients with a severe obstructive ventilatory dysfunction(less than 35% of predicted $FEV_1$) compared to those with a mild and moderate ventilatory dysfunction. The tei indices showed an inverse correlation to with the ejection time (r=-0.469), the isovolumetric contraction time/ejection time(r=0.453), the isovolumetric relaxation time/ejection time(r=0.896) and the preejection period/ejection time(r=0.480). Conclusion : The tei index appeared to be a useful noninvasive means of evaluating the right ventricular function. It revealed a significant correlation with the pulmonary function in patients with COPD.

  • PDF

A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 마모저항성에 관한 연구)

  • Yun, Yeon-Hee;Kim, Jung-Wook;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.217-225
    • /
    • 2002
  • When we use the flowable resin on the primary molars for quick handling, one of the most important property is the wear resistance. This study was performed to compare the wear resistance characteristics of four flowable composite resins [Arabesk flow (group 1), Tetric flow (group 2), Aeliteflow (group 3), Filtek flow (group 4)] to that of one control composite resin [Z100 (group 5)]. Specimen discs(n=10), 10mm wide and 2mm thick, were stored in distilled water at $37^{\circ}C$ for 7 days prior to testing. The specimens were subjected to 50,000 strokes at 2 Hz on the MTS system. During the test, the following parameters were maintained: the lateral excursion at 0.4mm, occlusal force at 2-100N with a force profile in the form of a half sine wave. The measurements of volume loss, depth of wear, and Vicker's hardness number of composite resins, and SEM observations of the polished and abraded surfaces were established. One-way ANOVA and Scheffe's multiple comparison test were employed to detect statistically significant differences among the flowable composite resin groups and the control composite group at P<.05. The following results were obtained: 1. Group 3 showed the least volume loss, while group 4 showed the greatest. The mean volume loss increased in the following order: group 3

  • PDF

Estimation of Dynamic Material Properties for Fill Dam : II. Nonlinear Deformation Characteristics (필댐 제체 재료의 동적 물성치 평가 : II. 비선형 동적 변형특성)

  • Lee, Sei-Hyun;Kim, Dong-Soo;Choo, Yun-Wook;Choo, Hyek-Kee
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.87-105
    • /
    • 2009
  • Nonlinear dynamic deformation characteristics, expressed in terms of normalized shear modulus reduction curve (G/$G_{max}-\log\gamma$, G/$G_{max}$ curve) and damping curve (D-$\log\gamma$), are important input parameters with shear wave velocity profile ($V_s$-profile) in the seismic analysis of (new or existing) fill dam. In this paper, the reasonable and economical methods to evaluate the nonlinear dynamic deformation characteristics for core zone and rockfill zone respectively are presented. For the core zone, 111 G/$G_{max}$ curves and 98 damping curves which meet the requirements of core material were compiled and representative curves and ranges were proposed for the three ranges of confining pressure (0~100 kPa, 100 kPa~200 kPa, more than 200 kPa). The reliability of the proposed curves for the core zone were verified by comparing with the resonant column test results of two kinds of core materials. For the rockfill zone, 135 G/$G_{max}$ curves and 65 damping curves were compiled from the test results of gravelly materials using large scale testing equipments. The representative curves and ranges for G/$G_{max}$ were proposed for the three ranges of confining pressure (0~50 kPa, 50 kPa~100 kPa, more than 100 kPa) and those for damping were proposed independently of confining pressure. The reliability of the proposed curves for the rockfill zone were verified by comparing with the large scale triaxial test results of rockfill materials in the B-dam which is being constructed.

A Study of Upper Airway Resistance Syndrome : Clinical and Polysomnographic Characteristics (상기도저항 증후군에 대한 연구 : 임상 및 수면다원검사 특징)

  • Yang, Chang-Kook;Clerk, Alex
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • Objectives : Upper airway resistance syndrome(UARS) is a sleep-related breathing disorder characterized by abnormal negative intrathoracic pressure during sleep. Abnormally increased negative intrathoracic pressure results in microarousal and sleep fragmentation which underlay UARS-associated complaints of daytime fatigue and sleepiness. Although daytime dysfunction in patients with UARS is comparable to that of sleep apnea syndrome, UARS has been relatively unnoticed in clinical setting. That is why UARS is apt to be excluded in diagnosing of sleep-related breathing disorders since its respiratory disturbance index and arterial oxygen saturation are within normal limits. The current study presents a summary of clinical and polysomnographic characteristics found in patients with UARS. The present study aims (1) to explore characteristics of patients diagnosed with UARS, (2) to characterize the polysomnographic findings of UARS patients, and (3) to enhance the understanding of UARS through those clinical and laboratory characteristics. Methods : This was a retrospective study of 20 UARS patients (male 15, female 5) and 30 obstructive sleep apnea (OSA) patients (male 21, female 9) at the Stanford Sleep Disorders Clinic. We diagnosed patients as having UARS when they met critenia, RDI < 5 characteristic findings of an elevated esophageal pressure($<-10\;cmH_2O$), frequent arousals secondary to an elevated esophageal pressure, and symptoms of daytime fatigue and sleepiness. We used polysomnographic value, which is standardized by Williams et al(1974), as normal control. Statiotical test were done with student t-tests. Results : (1) Mean age of UARS was $41.0\;{\pm}\;14.8$ years and OSA was $50.9\;{\pm}\;12.0$ years. UARS subject was significantly younger than OSA subject (p<0.05). (2) The total score of Epworth Sleepiness Scale (ESS) was UARS $9.7\;{\pm}\;6.3$ and OSAS $11.2\;{\pm}\;6.3$. There was no significant difference between two groups. (3) The mean body mass index was UARS $28.1\;{\pm}\;5.7\;kg/m^2$ and OSAS $32.9\;{\pm}\;7.0\;kg/m^2$. UARS had significantly lower meen body man index than OSAS subjects (p<0.05). (4) The polysomnographic parameters of UARS were not significantly different from those of OSA except RDI(p<0.001), $SaO_2$ (p<0.001) and slow wave sleep latency (p<0.05). (5) Compared with normal control, Total sleep time in UARS subjects was significantly shorter (p<0.001), sleep efficiency index was significantly lower (p<0.001), total awakening percentage was significantly higher (p<0.001), and sleep stage 1 (p<0.001) were significantly higher. (6) OSA patients showed poor sleep quality and distinct abnormal sleep architectures compared with normal control. Conclusions : Conclusions from the above results are as follows : (1) UARS patients were younger and had lower body mass index when umpared with OSA patients. (2) The quality of sleep and sleep architectures of the UARS and OSA patients are significantly different from those of normal control. (3) ESS scores and awakening frequencies of UARS are similar with those of OSA, suggesting that daytime dysfunction of UARS patients may be comparable to those of OSA patients. (4) The RDI and the $SaO_2$ which are important indicators in diagnosing sleep-related breathing disorders, of UARS subjects are close to normal value. (5) According to the the above results, we unclude that despite the absence of $SaO_2$ drops and the absence of an elevated number of apnea and hypopnea, subjects developed clinical complaints which were associated with laborious breathing, elevated Pes nadir, and frequently snoring. (6) Accordingly, we suggest including LIARS in the differential diagnosis list when sleep related breathing disorder is suspected clinically and overnight polysomnographic findings except snoring and frequent microarousal are within normal limits.

  • PDF