• Title/Summary/Keyword: Wave field measurement

Search Result 293, Processing Time 0.026 seconds

Measurement System of a Distance from Lightning Strokes to Observatory and Spectrum Analysis of Electric Fields Radiated from Lightning Discharges (뇌격거리측정계 및 뇌방전에 의해 발생하는 전장의 스펙트럼 분석)

  • Lee, B.H.;Chang, S.H.;Jeang, K.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1656-1658
    • /
    • 1998
  • This paper deals with a measurement system of a distance between lightning strokes and observatory station and spectrum analysis of electric fields radiated from lightning discharges. The distance measurement system, which consists of a loop type magnetic field sensor, a microphone and one chip microprocessor, is connected to a personal computer through RS232 port to acquire and process the data. This system is to use a difference of propagation velocity between an electromagnetic wave and a sonic wave produced by lightning discharge. Also, an electric field waveform and a frequency spectrum were investigated by an electric field measurement system with a hemisphere antenna and a spectrum analyzer with a biconical antenna and a log-periodic antenna, respectively. The results would be used as a basic reference to protect the power systems and electric circuits from lightning overvoltages.

  • PDF

Application of PIV in a Transonic Centrifugal Impeller

  • Hayami Hiroshi;Hojo Masahiro;Aramaki Shinichiro
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.1-5
    • /
    • 2001
  • A particle image velocimetry (PIV) was applied to a flow measurement in a transonic centrifugal impeller. A phase locked measurement technique every $20\%$ blade pitch enabled a reconstruction of a velocity field over one blade pitch. The measured velocity field at the inducer of impeller clearly showed a shock wave generated on the suction surface of a blade.

  • PDF

Yoke Topology Optimization of the Bias Magnetic System in a Magnetostrictive Sensor (자기변형 센서 바이어스 자기계의 요크 위상최적설계)

  • Kim, Yoon-Young;Kim, Woo-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.923-929
    • /
    • 2004
  • A magnetostrictive sensor is a sensor measuring elastic waves. Because of its unique non-contact measurement feature, the sensor receives more attentions in recent years. These sensors have been mainly used to measure longitudinal and torsional waves in ferromagnetic waveguides, but there increases an interest in using the sensor for flexural wave measurement. Since the performance of the sensor is strongly influenced by the applied bias magnetic field distribution, the design of the bias magnetic system providing the desired magnetic field is critical. The motivation of this investigation is to design a bias magnetic system consisting of electromagnets and yokes and the specific objective is to formulate the design problem as a bias yoke topology optimization. For the formulation, we employ linear magnetic behavior and examine the optimized results for electromagnets located at various locations. After completing the design optimization, we fabricate the prototype of the proposed bias magnetic system, and test its performance through flexural wave measurements.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Evaluation of Electromagnetic Shielding Efficiency of Magnetite-Carbon based Inorganic Paint (Magnetite-Carbon계 전자파흡수 무기도료의 현장 전자파 저감 성능 평가)

  • Park, Dong-Cheol;Lee, Se-Hyoen;Song, Tae-Hyeop;Sim, Jong-Woo;Park, Jae-Myoung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.141-144
    • /
    • 2004
  • Nowadays, there has been substantial interest in whether there is an association between electromagnetic field exposure and living environment. It is increased the demand that electromagnetic wave environment and its countermeasure. In the present study, we has applied the electromagnetic absorbent inorganic paint of 'I' corporations, and measured electromagnetic waves generated in new apartment before occupancy using the standard field electromagnetic wave generating device we developed. The measurement before occupancy was $100\~131V/m$, but the measurement after occupancy was $6.9\~8.0V/m$ less than 10V/m, the comprehensive electromagnetic wave limit allowed by TCO in Sweden. The implication is that domestic apartment are exposed to extremely poor electromagnetic wave environment. Nevertheless, there have been neither serious efforts to overcome this problem, nor its alternatives and related standards. Therefore, it is necessary to continue research of related fields to establish standards and plans to improve the situation.

  • PDF

Comparison of Observed Wave Height and Wave Image of Sok-cho Site (속초연안지점의 관측파고와 파영상자료의 비교)

  • Jang, Bok-Jin;Yeo, Woon-Kwang;Lee, Jong-Kook;Park, Kwang-Soon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.4
    • /
    • pp.329-335
    • /
    • 2007
  • The eye measurement to observe the sea surface condition and estimate the wave height has been used in the open sea or the ship. The experts in the eye estimation can measure the wave height very accurately. The Beaufort wind scale is most widely used as a standard index of the eye measurement. However, more definite reference data such as the representative images by each wave heights must be necessary because the appearances and explanations in the Beaufort wind scale are not enough to understand the sea surface condition far the researcher and the public. The modern field data acquisition technique has been developed to measure wave heights, ocean weather data and even images of the sea surface in real-time. In this study, the wireless field image transmitting system for wave heights and images is installed in the real-time ocean measurement system of Chodo light tower near Sokcho city in South Korea. The wave heights and surface images acquired from the real time system in the field are compared with explanations of the Beaufort wind scale. The wave heights and images measured with the precision ultrasonic wave sensor and the scientific sea surface image transmitting system should be helpful to obtain more precise and definite information than the data from the Beaufort wind scale.

Measurement-Based Propagation Channel Characteristics for Millimeter-Wave 5G Giga Communication Systems

  • Lee, Juyul;Liang, Jinyi;Kim, Myung-Don;Park, Jae-Joon;Park, Bonghyuk;Chung, Hyun Kyu
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1031-1041
    • /
    • 2016
  • This paper presents millimeter-wave (mmWave) propagation characteristics and channel model parameters including path loss, delay, and angular properties based on 28 GHz and 38 GHz field measurement data. We conducted measurement campaigns in both outdoor and indoor at the best potential hotspots. In particular, the model parameters are compared to sub-6 GHz parameters, and system design issues are considered for mmWave 5G Giga communications. For path loss modeling, we derived parameters for both the close-in free space model and the alpha-beta-gamma model. For multipath models, we extracted delay and angular dispersion characteristics including clustering results.

Development of Electromagnetic Wave Immunity Test system (전자파내성시험용 측정시스템의 개발에 관한 연구)

  • 정세모;김동일;배대환
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.2
    • /
    • pp.97-107
    • /
    • 1996
  • The method of Electromagnetic Wave Immunity Test is continuously endeavored by IEC and CISPR as international unification, but it has not been established yet. The main reason is why it is difficult to obtain the measurement method and normalization of threshold to find out the complicated parameters for Electromagnetic Wave immunity Test. So far, thus, the Electromagnetic Wave Immunity Test is carried out case by case as the electromagnetic environment, which is set up Electromagnetic Wave Immunity Test. This study has developed an algorithm and measurement software suitable for IEC1000-4 Regulations, where a ready-made Amplifier, and Signal Generator have been used and an interconnecting Interface Board has been constructed for connecting with the other apparatuses, i.e., RF Switch, Power Meter, Field Sensor, Pre-Amp., etc. Therefore, we have achieved the aim to develop an automated software using OOP method and the measurement system.

  • PDF

NEAR=FIELD DIFFRACTION PATTERN BY A SPHERICAL AIR CAVITY IN A DIELECTRIC MEDIUM (유전체 매질내에 있는 구형공동에 의한 근거리 회절패턴)

  • 강진섭;라정웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.19-30
    • /
    • 1995
  • Diffraction patterns of the copolarized and the crosspolarized total electric fields by a spherical air cavity in a dielectric medium are analyzed in the forward near-field region when the wavelength of the incident plane wave is comparable to one half of the cavity radius. It is shown that double nulls and dips of the copolarized and the crosspolarized total electric fields exist in the measurement plane tansverse to the propagating direction of the incident field, and their dependences on the frequency, the distance of the measurement plane, and the measurement angle are analyzed.

  • PDF

A Study on the Measurement of Ship Wave (항주파 관측에 관한 연구)

  • Jung, Dae-Deug
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.4
    • /
    • pp.297-301
    • /
    • 2008
  • On-site measurement of ship wave has been carried out in the vicinity of Mokpo inner harbour. The wave data were collected and logged 5Hz by the ultrasonic instrument for 12hour on May 17, 2006. The number of data was 216,000 and the maximum wave height was 81.41cm in normal weather condition. It was found that the wave conditions in this water area are predominantly affected by the ship-generated waved under normal condition. By comparing with the wind-generated waves in the open region which were irregular but with dominant directional characteristics, the existing harbor wave field was much more complex.

  • PDF