• 제목/요약/키워드: Wave Parameters

검색결과 1,605건 처리시간 0.035초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

지진동모델 파라미터 동시역산을 이용한 지진관측소 분류 (Classification of Seismic Stations Based on the Simultaneous Inversion Result of the Ground-motion Model Parameters)

  • 연관희;서정희
    • 지구물리와물리탐사
    • /
    • 제10권3호
    • /
    • pp.183-190
    • /
    • 2007
  • 지진기록의 수평성분 S파 푸리에스펙트럼을 이용한 추계학적 지진동모델(stochastic point-source ground-motion model; Boore, 2003) 파라미터 역산결과를 기반으로 지진공학적으로 활용될 수 있는 지진관측소 분류를 시도하였다. 추계학적 지진동모델에서 부지효과는 고주파감쇠상수인 $K_0$ (Anderson and Hough, 1984)와 지층의 탄성임피던스의 차이에 의해 발생하는 부지증폭함수(A(f))의 조합으로 표현된다. 본 연구에서는 A(f)를 지진파 스펙트럼의 수평/수직성분비(H/V)와, 이를 초기값으로 하여 얻어진 역산결과에 의한 관측소별 로그오차평균을 합산하여 계산하였다. 지진관측소는 $1{\sim}10$ Hz 범위의 부지증폭함수의 상용로그 최대값($logA_{1-10}^{max}$(f))에 의해 다섯 등급(A: $logA_{1-10}^{max}$(f) < 0.2, B: 0.2 $\leq$ $logA_{1-10}^{max}$(f) < 0.4, C: 0.4 $\leq$ $logA_{1-10}^{max}$(f) < 0.6, D: 0.6 $\leq$ log < 0.8, E: 0.8 $\leq$ $logA_{1-10}^{max}$(f))으로 분류하였다. 분류된 진관측소의 평균적인 부지증폭함수는 A에서 E 등급으로 변함에 따라 지반의 고유진동수가 저주파로 이동하는 의미 있는 결과를 나타내었으며, 최근에 설치장소를 이전한 기상청 일부 관측소에 대해 이설 전후의 등급변화 및 최근 발생한 중규모 지진관측자료와 지진동 거리감쇠식과의 비교분석을 통해 관측소 분류결과의 타당성을 입증할 수 있었다.

수면다원기록법으로 확진된 폐쇄성 수면무호흡증 환자의 임상특성, 그리고 호흡장애지수와 수면 구조간의 상관관계 (Clinical Characteristic and Respiratory Disturbance Index as Correlates of Sleep Architecture in Obstructive Sleep Apnea Syndromes Diagnosed with Polysomnography)

  • 김석주;박두흠;김용식;우종인;하규섭;정도언
    • 수면정신생리
    • /
    • 제8권2호
    • /
    • pp.113-120
    • /
    • 2001
  • 배 경 : 폐쇄성 수면무호흡증은 다양하고 심각한 임상 증상과 합병증을 유발하는 질환으로 국내에서도 흔히 진단되고 있다. 그러나 현재까지 수면다원기록법을 사용해 폐쇄성 수면무호흡증을 확진한 환자들의 대규모 국내 연구를 찾아 볼 수 없었다. 본 연구에서는 종래의 연구에서보다 더 큰 집단을 대상으로 수면다원기록법을 사용해 폐쇄성 수면무호흡증으로 확진된 한국인 환자의 임상적 특성과 수면 양상에 관해 조사하였다. 방 법 : 서울대학교병원 수면다원검사실에 의뢰된 환자들 중 수면다원검사 결과 폐쇄성 수면무호흡증으로 진단된 환자 801명을 대상으로 하였다. 중추성 무호흡증, 주기성 사지운동증, 기면병, 렘수면관련행동장애, 그리고 외국인 환자는 제외하였다. 연구 대상 군의 임상적 특징을 조사하였으며 수면 변인들을 연령, 성별에 따른 정상치와 비교하였다. 그리고 호흡장애지수가 수면변인에 미치는 영향을 분석하였다. 결 과 : 전체 연구대상자 801명 중 남자가 83.4%, 여자가 16.4%이었고 평균 연령은 46.6세였다. 평균 비만정도 지수는 25.8이었고 비만한 환자가 22.8%를 차지하였다. 전체 대상 중 6.2%가 벤조디아제핀계 약물을 복용 중이었다. 연구 대상군에서 정상치에 비해 입면잠복시간은 증가되었고 수면효율, 렘수면 분율, 그리고 서파수면 분율은 감소하였다. 서파수면 분율과 렘수면 분율은 각각 호흡장애지수와 음의 상관성을 보였으나 수면효율과 입면잠복시간은 모두 호흡장애지수와 유의한 상관관계가 없었다. 결 론 : 본 연구에서 다수의 폐쇄성 수면무호흡증 환자가 비만과 무관하였다. 또한 6.2%의 폐쇄성 수면무호흡증 환자가 벤조디아제핀계 약물을 복용하고 있었다. 폐쇄성 수면무호흡증의 발병은 수면효율도 낮추고 서파수면과 렘수면 분율을 감소시키나 호흡장애지수가 커져도 서파수면과 렘수면 분율이 감소할 뿐 수면효율은 별 다른 변화가 없었다. 즉, 수면효율보다는 수면 구조의 변화가 수면 중 호흡장애의 정도에 더 관련되었음을 알 수 있었다.

  • PDF

단계별(段階別) 가압(加壓)에 따른 좌관부위(左關部位) 맥파(脈波) 변화(變化) (A Study on the Waveform Analysis of Left KWAN Pulse Dignosis by the Pressure)

  • 김경철;이정원;류경호;김종환;박주연
    • 대한한의진단학회지
    • /
    • 제13권1호
    • /
    • pp.19-35
    • /
    • 2009
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundamentals of contemporary pulse diagnosis research. To achieve certain experimental basis on traditional pulse diagnosis, we have to research the differences of pulse waveform according to pressure (in 5 level) and position (Chon, Gwan, Cheok in radial artery). As a first step, in present thesis, we tried to find the differences of pulse waveform according to pressure. Methods and Results : In this research, we analyzed seven parameters of the waveform at five levels of pressure. The parameters are E(so called 'energy', a representative of pulse strength), h1(height of percussion wave) and h2(height of subincisura). The results were as follows. 1. When we analyzed the change of the waveform according to pressure in the left Gwan, E, hl, h2 and A differed between 1st and 2nd grade, between 1st and 3rd grade, between 1st and 4th grade, between 1st and 5th grade, between 2nd and 3rd grade, between 2nd and 5th grade, between 3rd and 5th grade and between 4th and 5th grade in 95% confidence interval. 2. And t2, t4 differed between 1st and 2nd grade, between 1st and 5th grade, between 2nd and 4th grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade and between 4th and 5th grade in 95% confidence interval. 3. W differed between 1st and 3rd grade, between 1st and 4th grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade, and between 4th and 5th grade in 95% confidence interval. 4. And h2/h1 differed between 1st and 4th grade, between 1st and 5th grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade & between 3rd and 5th grade in 95% confidence interval. 5. There were differences between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% confidence interval. And there were differences between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% confidence interval. And were differences between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% confidence interval. Conclusions : As mentioned above, we conclude that the waveform analysis according to five grade pressure in the left Gwan shows the difference of waveform in each grade pressure.

  • PDF

족삼리(足三里) 배혈(配穴)에 따른 전침(電鍼)이 흰쥐 대뇌피질(大腦皮質)의 NADPH-diaphorase와 nNOS, NPY, VIP 신경세포(神經細胞)에 미치는 영향(影響) (Effect of Joksamni combination on NADPH-diaphorase, neuronal Nitric Oxide Synthase, Neuropeptide Y and Vasoactive Intestinal Peptide in the cerebral cortex of Spontaneously Hypertensive Rat)

  • 정인기;이재동;김창환
    • Journal of Acupuncture Research
    • /
    • 제20권5호
    • /
    • pp.118-132
    • /
    • 2003
  • Objective: The aim of this study was to investigate the effects of Joksamni(ST36) combination on NAD PH-diaphorase, neuronal nitric oxide synthase(nNOS), neuropeptide Y(NPY) and vasoactive intestinal peptide (VIP) in the cerebral cortex of spontaneously hypertensive rat. Methods: The experimental groups were divided into four groups: Normal, Joksamni(ST36), Joksamni(ST36)+Eumneungcheon(SP9), and Joksamni(ST36)+Gokji(LI11). Needles were inserted into acupoints at the depth of 0.5cm with basic insertion method. Electroacupuncture was done under the condition of 2Hz electrical biphasic pulses with continuous rectangular wave lasting for 0.2ms until the muscles produced visible contractions. Such stimulation was applied continuously for 10 minutes, 1 time every 2 days for 10 sessions of treatments. Thereafter we evaluated changes in NADPH-d positive neurons histochemically and changes in nNOS, NPY and VIP positive neurons immunohistochemically. Results: The optical densities of NADPH-d positive neurons of the Joksamni(ST36)+Eumneungcheon(SP9) group in all areas of cerebral cortex and Joksamni(ST36)+Gokji(LI11) group in primary somatosensory cortex, visual cortex, auditory cortex, perirhinal cortex were significantly increased as compared to the Joksamni(ST36) group. The optical densities of NADPH-d positive neurons of the Joksamni(ST36)+Gokji(LI11) group were significantly decreased as compared to the Joksamni(ST36)+Eumneungcheon(SP9) group with the exception of primary somatosensory cortex. The optical densities of nNOS positive neurons of the Joksamni(ST36)+Eumneungcheon(SP9) group in all areas of cerebral cortex and Joksamni(ST36)+Gokji(LI11) group in auditory cortex, perirhinal cortex, insular cortex were significantly increased as compared to the Joksamni(ST36) group. The optical densities of nNOS positive neurons of the Joksamni(ST36)+Gokji(LI11) group were significantly decreased in all areas of cerebral cortex as compared to the Joksamni(ST36)+Eumneungcheon(SP9) group. The optical densities of NPY positive neurons of the Joksamni(ST36)+Gokji(LI11) group were significantly decreased in primary motor cortex, primary somatosensory cortex, cingulate cortex as compared to the Joksamni (ST36) and Joksamni(ST36)+Eumneungcheon(SP9) groups. The optical densities of VIP positive neurons of the Joksamni(ST36)+Eumneungcheon(SP9) group were significantly increased in all areas of cerebral cortex except for cingulate cortex as compared to the Joksamni(ST36) group. The optical densities of VIP positive neurons of the Joksamni(ST36)+Gokji(LI11) group were significantly decreased in auditory cortex, cingulate cortex, perirhinal cortex as compared to the Joksamni(ST36) group. The optical densities of VIP positive neurons of the Joksamni(ST36)+Gokji(LI11) group were significantly decreased in all areas of cerebral cortex as compared to the Joksamni(ST36)+Eumneungcheon(SP9) group. Conclusions: The result demonstrated that electroacupuncture on Joksamni(ST36) and its combination change the activities of the NO system and peptidergic system in the cerebral cortex of SHR and that acupoint combination is one of the important parameters for the effects.

  • PDF

하구언 수문작동으로 인한 금강 하구역의 물리적 환경변화: II. 염분구조와 하구유형 (Physical Environment Changes in the Keum River Estuary by the Dyke Gate Operation: II. Salinity Structure and Estuary Type)

  • 이상호;권효근;최현용;양재삼;최진용
    • 한국해양학회지:바다
    • /
    • 제4권4호
    • /
    • pp.255-265
    • /
    • 1999
  • 금강하구언 수문작동이후 물성구조와 하구유형을 조사하기 위하여 1997년 6월, 7월 및 10월, 1998년 5월과 7윌에 CTD와 조류관측을 하였다. 조석과 조류의 관계는 고조전에 조류가 전류되어 낙조가 창조보다 1.5시간 정도 길다. 풍수기에는(5월부터 7월) 낙조시에 하구언에서 담수를 간헐적으로 대량 방류하여 하구 상류쪽의 수직적 염분차이와 염분의 시간변화가 커지고 하계 홍수시 2‰ 미만의 염분이 나타난다. 유출담수에 의한 염분약층의 발달로 2층구조를 보이며, 약층의 세기와 깊이는 저조시에 증가한다. 조석위상과 표층염분 변화의 관계는 히구 상류쪽에서 약 2.5 시간의 위상차이를 보이나 하구 하류쪽에서는 정상파 관계를 보인다. 하구 상류쪽에서의 위상차이는 낙조시 2~3시간 정도 방류된 담수에 의해 생성된 저염수가 조류에 의해 이동된 것을 의미한다. 갈수기에는 수직염분차이가 현저히 줄어든다. 관측된 표층유속과 염분구조 및 담수방류량을 사용하여 성층계수, 순환계수를 산출하였다. 금강하구는 부분혼합형 하구이고 풍수기와 갈수기에 따라 성층계수가 달라진다. 관측된 조류의 평균적 흐름은 상층에서 바다쪽으로, 저층에서 육지쪽으로 향하여 부분혼합형 하구의 전형적 순환형태와 일치하였다. 이러한 하구언 수문작동 후의 금강하구 유형과 순환은 하구역에서 저층부유사가 상류쪽으로 이동하며 퇴적되는 환경임을 제시한다.

  • PDF

Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가 (Evaluation of cardiac function by tissue Doppler imaging in children with cancer)

  • 김여향
    • Clinical and Experimental Pediatrics
    • /
    • 제49권4호
    • /
    • pp.417-423
    • /
    • 2006
  • 목 적 : 항암제와 방사선 치료의 개발, 골수나 조혈모세포 이식 기회의 증가로 소아 백혈병과 고형 종양을 가진 환아들이 장기 생존하게 되면서 치료에 따른 장기 부작용, 특히 심장 독성에 크게 관심을 가지게 되었다. 항암제에 의한 심장 독성을 파악하는데 가장 적절한 방법은 비침습적이면서 정량적으로 측정할 수 있는 심초음파라고 할 수 있다. 본 연구에서는 이미 소아암으로 진단을 받고 치료를 받는 중이거나 치료를 종료한 환아들을 대상으로 조직 도플러 영상을 사용하여 심실 기능을 평가하고, 향후 동질환의 환아에서 조기 및 후기 심독성을 조기에 발견하기 위한 방법으로 반복적인 조직 도플러 영상을 적용하는데 기여하고자 하였다. 방 법 : 2005년 4월 1일부터 7월 1일까지 계명대학교 동산의료원 소아 종양 크리닉을 방문한 항암치료 중이거나 항암치료 종료된 환아 23명을 대상으로 하였다. 전체 대상 환아군(1군)은 단축 분획 29% 이상(2군), 28% 이하의 군(3군)으로 나누고, anthracyclin 사용군(4군)과 미사용군(5군)으로 다시 나누었다. M-mode와 간헐파 도플러를 이용하여 단축 분획, 구혈률, 승모판막으로 유입되는 혈류의 E, A 속도, DT, IVRT를 측정하였고, 조직 도플러 영상을 이용하여 심첨 4, 2 방도에서 중격, 전벽, 하벽, 측벽의 기저부, 중간, 심첨 부위의 Sm, Em, Am 속도를 측정하였다. 측정한 값을 이용하여 modified Tei index, E/A, E/Em ratio를 구하였다. 결 과 : 환아의 평균 나이는 8년 4개월이었고 남아 12명, 여아 11명이었다. 항암제 중 anthracyclin을 사용한 환아(4군)는 13명이었고, 방사선 치료를 받은 환아는 4명이었으며 단축 분획이 28% 이하인 환아(3군)는 6명이었다. 대조군의 평균 나이는 6년 6개월이었고 남아 6명, 여아 3명이었다. 환아군과 대조군간에 성별, 나이에 있어서 유의한 차이는 없었다. 대조군과 1군의 E/Em ratio는 $7.06{\pm}1.64$, $6.46{\pm}1.85$로 두 군간에 P<0.05로 의미있는 차이가 있었으나 다른 측정값들은 유의한 차이가 없었다. 대조군과 2, 3, 4, 5군간에도 E/Em ratio는 P<0.05로 의미있는 차이가 있었다. 2, 3군과 4, 5군간에는 측정값들의 군간의 유의한 차이가 없었다. 결 론 : 좌심실 평균 이완기압을 반영한다고 알려져 있는 E/Em ratio에서 대조군과 항암 치료 군간에 차이가 확인됨으로써 항암 치료 이후의 심장 기능 부전은 수축기 기능 변화가 아닌 이완기 기능 변화가 먼저 오는 것을 알 수 있었다. 심장 이완기 기능을 평가하는 간헐파 도플러 측정값들에서는 두 군간에 차이가 없음으로 이완기 기능을 평가하는데는 조직 도플러 영상을 이용하는 것이 더 민감한 방법이었다. 따라서 항암 치료 이후에도 장기적으로 관심을 가지고 심장 기능에 대한 잦은 추적 관찰이 필요하겠고, 추적 관찰하는 방법으로는 조직 도플러 영상을 이용한 심초음파 검사가 비침습적이고 간편하며 유용한 방법일 수 있다.

정상 망막과 변성 망막을 위한 전기자극 파라미터 (Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina)

  • 진계환;구용숙
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.73-79
    • /
    • 2008
  • 망막색소변성(retinitis pigmentosa: RP)과 연령 관련 황반변성(age-related Macular Degeneration: AMD)은 망막변성으로 인해 실명에 이르는 대표적인 질환이며 망막이식장치의 개발을 통해 치료될 수 있다고 간주되고 있다. 최근에 국내에서도 망막이식장치 개발을 위한 연구팀이 조직되었다. 성공적인 망막이식장치 개발을 위하여 여러 가지 선결요소가 필요하지만 그 중 한 가지가 이식장치에 인가할 전기자극을 최적화하는 것이다. 변성망막의 전기적 특성은 정상 망막과 다르리라 예측되므로 우리는 장차 개발될 망막 이식장치에 인가할 전기자극 최적화를 위한 가이드라인을 제공하기 위해 정상 망막과 변성 망막의 전압자극 파라미터에 관한 실험을 하였다 망막을 분리한 후 망막절편을 신경절세포 층이 다채널전극의 표면을 향하게 하여 전극에 붙인다 in-vitro 상태에서 망막 신경절세포의 전기신호를 기록하기 위해 전극 직경: $30{\mu}m$, 전극간 거리: $200{\mu}s$, 전극 임피던스 1kHz 에서 $50k{\Omega}$인 8행 8열의 다채널전극을 사용하였다. 다채널전극의 60채널 중 두 채널을 자극전극과 접지로 사용하여 단극전기자극을 인가하였고 나머지 전극을 기록전극으로 사용하였다. 가한 전기자극은 전압자극으로 전하균형을 맞춘 이상성자극을 아노딕 사각파를 먼저 주고 캐쏘딕 사각파가 나중에 나오는 형태로 두 사각파간의 지체는 없도록 하였으며 동일한 자극을 2초 간격으로 50회 반복하여 인가하였다. 다양한 전기자극을 사용하였는 바 첫째는 사각파의 크기를 달리하였다 $(0.5{\sim}3V)$. 둘째는 사각파의 시간을 달리하였다 $(100{\sim}1,200{\mu}s)$. 전하밀도는 옴의 법칙과 쿨롱의 법칙을 이용하여 계산하였다. 전기자극으로 유발된 반응은 50회 자극에 대한 평균치를 얻은 후 자극 후 히스토그램(PSTH)을 그려 분석하였다. 전압자극의 크기를 $0.5{\mu}3V$로 달리하였을 때 믿을 만한 망막신경절세포가 유발되는 자극은 1.5V이었고 이때 계산된 전하밀도의 역치는 $2.123mC/cm^2$이었다. 전압의 크기를 2V로 고정하고 자극 지속시간을 $100{\sim}1,200{\mu}s$로 달리하였을 때 믿을 만한 망막신경절세포가 유발되는 자극의 역치는 $300{\mu}s$에서 관찰되었다. 이때 계산된 전하밀도의 역치는 $1.698mC/cm^2$이었다. L-(1)-2-amino-4-phosphonobutyric acid (APB)을 사용하여 ON-경로를 차단한 후에 전기자극을 인가하였을 때도 자극에 의해 망막신경절 세포의 반응이 유발되는 것을 확인하였다. APB-변성망막에서 전압의 크기를 2V로 고정하고 자극 지속시간을 $100{\sim}1,200{\mu}s$로 달리하였을 때 믿을 만한 망막신경절세포가 유발되는 자극의 역치는 $300{\mu}s$에서 관찰되었으며 이는 정상망막의 결과와 같았다. 추후 APB-변성망막을 가지고 좀더 실험이 진행되어야 정상망막과 변성망막의 전하밀도에 관한 명료한 비교가 가능할 것이다.

  • PDF

X-선회절과 Raman 분광분석을 이용한 2성분계(CaO-, $Y_2O_3$-, MgO-$ZrO_2$) 및 3성분계(MgO-$ZrO_2-Al_2O_3)$ Zirconia의 상전이연구 (Phase Transformation of 2 Components(CaO-, $Y_2O_3$-, MgO-$ZrO_2$) and 3 Components(MgO-$ZrO_2-Al_2O_3)$ Zirconia by X-ray Diffraction and Raman Spectroscopy)

  • 은희태;황진명
    • 한국세라믹학회지
    • /
    • 제34권2호
    • /
    • pp.145-156
    • /
    • 1997
  • 2성분계(CaO-, Y2O3-, MgO-ZrO2) 및 3성분계(MgO-ZrO2-Al2O3)ZrO2분말의 안정화제 종류, 첨가량 및 열처리온도 변화에 따른 ZrO2의 상전이를 X-선 회절과 Raman분광법으로 연구하였다. CaO-, 및 Y2O3-ZrO2계에서 CaO와 Y2O3의 첨가량이 각각 6~15mol% 및 3~15mol%로 증가에 따른 정방정상에서의 입방정상으로의 상전이를 X-선회절 pattern으로는 판별하기 어려웠으나, Raman spectra에서는 모든 Raman band가 저파수쪽으로 이동하고 band의 수 및 그 세기가 현저히 감소함을 관찰할 수 있었다. 이것은 정방정$\longrightarrow$입방정의 상전이가 발생한 것으로 ZrO2 격자내에서 Zr4+ 이온과 Ca2+ 혹은 Y3+이온의 치환에 의해 산소이온의 빈자리 생성으로 인한 구조적 불규칙성과 선택규칙(k=0)의 파괴에 기인한 것으로 해석된다. MgO의 경우에는 10mol%에서 단사정에서 입방정으로 상전이가 발생하였다. MgO-ZrO2-Al2O3계에서는 Al2O3의 첨가에 의해 입방정$\longrightarrow$단사정의 상전이가 발생하는데 이것은 MgO와 Al2O3의 반응에 의해 spinel(MgAl2O4)의 형성으로 인하여 MgO가 충분히 안정화제로서의 역할을 하지 못하기 때문으로 판단된다. 또한, 안정화제의 종류와 첨가량 변화에 따른 ZrO2의 상전이를 ZrO2의 격자상수값의 변화와 관련하여 설명할 수 있는데, 즉, 안정화제의 첨가량이 증가할수록 격자상수 a값은 증가하고 c값은 감소하여 10~13mol%사이에서는 c/a의 축비가 1에 근접하고, 따라서 정방정$\longrightarrow$입방정의 상전이가 진행됨을 알 수 있었다.

  • PDF

조직 도플러 영상을 이용한 선천성 심장병 수술 전후의 단기 심기능 평가 (Evaluation of short-term cardiac function by tissue Doppler imaging in pre and postoperative period of congenital heart disease)

  • 이준화;김여향;현명철;이상범
    • Clinical and Experimental Pediatrics
    • /
    • 제50권5호
    • /
    • pp.476-483
    • /
    • 2007
  • 목 적 : 선천성 심장병을 가진 소아에서 체외 심폐 순환기를 이용한 개심술을 시행한 후 좌 우심실의 기능의 변화를 조직 도플러 영상을 이용하여 측정하고, 이를 개심술 이전과 비교함으로써 수술 이후의 심실 기능 변화를 살펴 보고자 하였다. 방 법 : 2005년 1월부터 2005년 12월까지 선천성 심장병으로 경북대학교병원 소아과에 입원하여 심초음파 및 진단적 심도자술 검사를 받은 후 개심술을 시행한 환자 총 78명 중 수술 전과 수술 후 1개월에서 3개월 사이에 심초음파를 시행하고, 두 번 모두 조직 도플러 영상이 기록된 환자 32명을 대상으로 하였다. 전체 환자군은 다시 3군으로 나누었는데, 좌심실 용적 과부하를 가지는 1군, 우심실 용적 과부하를 가지는 2군, 우심실 압력 과부하를 가지는 3군으로 분류하였다. 간헐파 도플러를 이용하여 승모판과 삼첨판 유입 혈류의 E, A 최대 속도를 측정하고, 조직 도플러 영상을 이용하여 심첨 4방도와 2방도에서 심실 중격, 승모판륜 및 삼첨판륜 외벽, 좌심실 후벽과 전벽의 기저부에서 Sm, Em, Am을 측정하였으며, E/Em을 구하였다. 결 과 : 개심술 당시 대상 환자 군의 평균 나이는 27개월(1개월-156개월)이었고, 남자 14명, 여자 18명이었다. 개심술을 시행한 심장병으로는 심실 중격 결손 13명, 심방 중격 결손 7명, 방실 중격 결손 3명, 단순 폐동맥 협착 2명, 및 활로씨 4징 7명이었다. 좌심실 용적 과부하 군인 1군의 승모판륜 외벽의 E/Em, 삼첨판륜 외벽의 Sm, Em, Am, 심실 전벽의 Em, Am, 우심실 용적 과부하 군인 2군의 삼첨판륜 외벽의 Sm, Em, Am, 심실 전벽의 Sm, Em, 심실 중격과 후벽의 Em, 우심실 압력 과부하 군인 3군의 삼첨판륜 외벽의 Sm, Em, Am, 심실 전벽의 Am 값들도 수술 전과 비교하여 수술 후에 통계학적으로 의미있는 감소가 있었다. 결 론 : 선천성 심장병 환자의 수술 전과 수술 후의 조직 도플러 영상 측정값을 비교하였을 때 모든 환자 군에서 삼첨판륜 외벽의 Sm, Em, Am 값의 감소를 보이고, 좌심실 용적 과부하군에서는 좌심실 이완기압을 반영한다고 할 수 있는 승모판륜 외벽의 E/Em 값이 수술 전에 비해 수술 후에 통계학적으로 유의한 감소를 보였다. 이들은 체외 심폐 순환기를 이용한 개심술의 심장에 대한 영향 및 선천성 심장병의 교정 후의 용적, 압력의 변화 영향을 모두 반영하는 것으로 생각된다. 그러나 이러한 결과가 어느 정도까지 체외 심폐 순환기를 이용한 개심술에 의한 영향을 반영하는지에 대해서는 더 많은 연구가 필요할 것으로 생각된다.