• 제목/요약/키워드: Waterproof Performance

검색결과 199건 처리시간 0.024초

유전가열 마이크로파를 적용한 방수·방염 내장목재 개발을 위한 기초적 연구 (A Fundamental Study for Development on Waterproof and Flame Retardant processing technology the Interior Wood of using Induced electricity heating Microwave)

  • 박철우;허재원;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.35-41
    • /
    • 2008
  • Qualitative enhancement of dwelling life has changing the recognition for the environment friendly wood which is being highlighted for its usage as an interior materials. This trend may prove the excellent performance of wood whose inherent characteristics has its comfortable, mild feeling of material, sound resistance and stabilities and the market of interior woods including floor, moulding and wooden panel as finishing interior materials is growing sustainably. However, since this materials is vulnerable to humidity and flame, waterproofing and flame retarding stability, an essential condition for interior materials, together with maintenance, are the main topics to be resolved. From the above-mentioned results, as a result of waterdrop contact angle, wood absorption volume and water content percentage test and the performance test of the processed materials after flame retardant, though there was some submerging time changes among types of woods for ensuring waterproofing performance improvement but as time passes, similar tendency was noticed to be formulated. As the submerging time is increased, so does the absorption volume and accordingly optimal level of range is judged to be drawn in order to ensure excellent performance, taking optimal economy into consideration. Therefore, it is considered that above-mentioned woods could be utilized for waterproof and flame retardant processed interior materials using uniform microwave and in order to put this technology into practical application, a research by way of diversified performance proving is required to be carried out.

  • PDF

고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구 (A Study on Improvement of the low temperature flex resistance test method about high waterproof materials)

  • 이민희;문선정;고혜지;홍성돈
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

건축물의 단열방수의 최적 공법및 구법 선정 방법론에 관한 연구 (A study on the choice of the best method of construction for building insulation and waterproof)

  • 이성구;박태근
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2006년도 정기학술발표대회 논문집
    • /
    • pp.654-658
    • /
    • 2006
  • 옥상방수의 기존 습식공법에서 나타나는 문제점을 해결하기 위하여 옥상마감 누름층을 기성 콘트리트 블럭으로 대체하여 시공함으로써 방수하자에 따른 과잉비용을 줄이고 증축이나 개보수시 자재의 재활용을 유도할 수 있는 방안의 필요성이 대두되고 있다. 이에 따라 본 연구에서는 제안된 옥상 외단열방수 건식화 공법에 대한 성능평가 항목 중 단열성능을 중심으로 실험을 통하여 종합적인 정량평가 및 분석을 실시함으로써 향후 건식화 공법의 시공 및 활용을 위한 기초자료를 제공하고자 한다. 그리고 건축물의 옥상단열방수에 있어서 발생되고 있는 하자의 원인분석 및 이에 따른 개선방안을 제시하고 수많은 단열방수재료와 다양한 공법 가운데서 건축물의 요구 성능에 가장 적합한 선정방법을 단계별 주요인자의 중요도에 따라 분류함으로써 건축물의 용도, 특성 및 중요도에 따른 공법, 구법 선정이 가능하도록 하였다.

  • PDF

저가 수중 무인 이동체 개발 및 운동성능 검증 (Development of a Low-cost Unmanned Underwater Vehicle and Performance Verification)

  • 황동욱;장민규;김진현
    • 로봇학회논문지
    • /
    • 제13권2호
    • /
    • pp.103-112
    • /
    • 2018
  • In this paper, a high performance underwater vehicle which can be manufactured at low cost is designed and fabricated, and its performance is verified through experiments. To improve efficiency, the Myring equation is used to design the appearance and the duct structure including the thruster is planned to increase the propulsion efficiency while reducing the drag force. Through various methods, it is secured stable waterproof performance, and also is devised to have high speed movement and turning performance. The developed underwater vehicle is equipped with a high output BLDC motor to achieve a linear speed of up to 2 m/s and can change direction rapidly with stability through four rudders. The rudders are driven by coupling a timing belt and a pulley by extending the axis of a servo motor, and are equipped at the end of the body to turn heading. In addition, for stable posture control, the roll keeps its internal center of gravity low and maintains its stability due to restoring force. By controlling the four rudders, pitch and yaw are handled by the PID controller and show stable performance. To investigate the horizontal turning performance, it is confirmed that the yaw rate controller is designed and stable yaw rate control is performed.

무기질계 탄성 도막재와 고무 아스팔트를 적층한 일체형 방수재의 시공특성에 관한 실험적 연구 (A study on a performance the appliable rubber asphalt of monolithic waterproofing material of construction quality and the cement polymer modified waterproof coating membrane material of surface treatment.)

  • 박진상;최성민;박영태;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.223-226
    • /
    • 2005
  • In this study on the appliable Asphalt sheet of monolithic and inorganic matter waterproofing ,Fing material using of field because of problem of complex waterproofing sheet. Before this cement polymer modified waterproof coating and appliable asphalt sheet of monolithic whether have stability by method of construction about all style waterproofing that evaluate to new method of construction development naturally big emphasis put and try to approach. Did performance test item first at, as a result, drew by suitable thing in all KS items. This is considered to have more effective spot construction work because if means that have stability by material as well as method of construction.

  • PDF

추적식 수상 태양광 발전 시스템 성능 분석 (The Efficiency Analysis of Tracking-Type Floating PV System)

  • 양연원;정선옥;신현우;이길송
    • Current Photovoltaic Research
    • /
    • 제1권2호
    • /
    • pp.122-125
    • /
    • 2013
  • The Floating Photovoltaic System was installed on the surface of water. There were some researches in this subject. But there was not many studies with experiment on a high waterproof Floating Photovoltaic modules. The aim of this study was to analyze the performance of the Floating Photovoltaic System. For this experiment, a high waterproof Floating Photovoltaic modules were designed and applied to the module capacity of 10 kW Tracking-Type structure. The experiment results indicated the performance of the daily production is 51.6 kW; the production capacity of Floating Photovoltaic System is expected to be 23% higher than that of the ground-mounted photovoltaic system.

콘크리트 구조체 내구성 향상을 위한 침투성 표면 보호재의 특성에 관한 실험적 연구 (An Experimental Study about Characteristics of Penetrating Surface Protection Materials to Promote Concrete Structure Durability)

  • 이정윤;조병영;김영근;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.93-96
    • /
    • 2005
  • Concrete has been considered as a semi-permanent structural material, because its excellent durability. Recently, durability decline of concrete construction by environmental pollution is becoming social problem. The durability of high durable structure is declined by carbonate, chloride permeation and deterioration of waterproof performance, etc. This study of penetrating surface protection materials evaluated about carbonation, chloride permeation, waterproof performance, and durability of abrasion, etc. It is profitable in durability that spread penetrating surface protection materials

  • PDF

표준화된 방수기술 평가기법 개발 및 평가체계 구축 (Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods)

  • 송제영;이선규;최은규;이정훈;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.341-342
    • /
    • 2018
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

표준화된 방수기술 평가기법 개발 및 평가체계 구축 (생산기술, 유지관리 평가 중심) (Proposed Development and Evaluation System for Existing Standardized Waterproof Technology Assessment Methods(Production technology, maintenance evaluation))

  • 송제영;서현재;최은규;이정훈;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2019
  • Waterproofing materials and construction methods have been developed and applied to various construction sites since the past. However, there many cases where the waterproofing performance is not satisfactory, leading to continuous water leakage. It has been observed that a key reason for this is because waterproofing method and material selection is not optimized in terms of the appropriate application area and environmental degradation factors. This paper proposes that future selection of waterproofing methods should consider the following evaluation criteria; 1) waterproof performance evaluation according to site conditions, 2) evaluation of construction method, 3) manufacturing and maintenance of waterproofing systems.

  • PDF

탄소섬유길이 및 혼입량에 따른 폴리우레아 도막방수재의 인장성능 변화 연구 (A Study on the Tensile Performance Change of Polyurea Waterproof Membrane Coat by Amount of Carbon Milled Fiber)

  • 박진상;최수영;박완구;김동범;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.242-243
    • /
    • 2017
  • Despite its excellent properties, polyurea coating waterproofing material is exposed to sunlight when it is applied to the exterior wall of concrete by exposed waterproofing method such as a roof of a building, resulting in a problem of causing a large deterioration in performance compared to initial properties. The purpose of this study is to investigate the effect of carbon fiber incorporation on the performance of carbon fiber - reinforced polyureas and to study the optimum carbon fiber length and content respectively. Result of the study confirmed that the performance of the carbon fiber was improved by 2% or more, and the carbon fiber length was 30 ㎛ and the mixing ratio was 3%. It is expected that stable durability can be secured when manufacturing fiber-incorporated polyureas.

  • PDF