• Title/Summary/Keyword: Water-paint

Search Result 131, Processing Time 0.031 seconds

Adsorption Characteristics of Waste-Paint Activated Carbon (廢 페인트 活性炭의 吸着特性)

  • 박정호;박승조
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.9-14
    • /
    • 2000
  • Comparing the adsorption characteristics of coconut shell activated carbon (CSAC) and waste paint activated carbon (WPAC), Freundlich adsorption isotherms of alkylbenzene sulfonate (ABS) obtained from the secondary treatment water of H company and effluent of D company were estimated q=23.12 $C^{0.42}$ , q=18.32 $C^{0.38}$ with WPAC and $q=36.76C^{1.37}$ /, q=26.67 $C^{0.42}$ with CSAC respectively. In the case of H company, breakthrough time of the ABS using CSAC by continuous experiment was estimated 680 minute md that of WPAC was 610 minute. In the case of D company effluent, CSAC was estimated 720 minute, and that of WPAC was estimated 640 minute to reach the breakthrough. From the above results, it is possible to replace the coco-nut shell activated carbon with wasted paint activated carbon.

  • PDF

A study on improvement of painting quality through a de-painting phenomenon of KUH-1 tail blade (한국형 기동헬기 꼬리 날개 디페인팅 현상을 통한 도장 품질 향상에 관한 연구)

  • Chang, In-Ki;Kim, Young-Jin;Seo, Hyun-Soo;Jeon, Boo-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.3
    • /
    • pp.325-338
    • /
    • 2014
  • Purpose: The purpose of this study was to explain de-painting phenomenon of KUH-1 tail blade and to propose useful solution of it by test. The proposed solution was evaluated by real flight, and then it applied to mass product to improve the paint qual ity of KUH-1 tail blade. Methods: This study investigated an adhesive ability of primer following surface sanding condition. The cross cut and scratch test were conducted to evaluate the adhesive strength. And the water flow test was designed to simulate a real flight condition under rain. Through water flow test, an optimal condition of tail blade to prevent a de-painting phenomenon was deduced. Finally, the improvement method was evaluated by real flight under rain. Results: The results of this study are as follows; The sequential polishing was most excellent method in primer painting quality. The results of test including cross cut, scratch and water flow showed that MIL-DTL-53039 paint with epoxy primer has excellent adhesive ability. To proof the effect of improvement, a real flight during a rain condition was conducted. Finally, the comparison between original and improved configuration was conducted. Conclusion: The painting quality of KUH-1 tail blade was improved through deriving an optimal painting condition. In detail, a condition of optimal sanding and a sort of primer and paint was showed. Finally, the reliability of tail blade was guaranteed through improving the quality of painting.

The Influence of Nano Synthesized Polymer Paint on Durability of Concrete (나노합성 무기질 폴리머계 표면처리제가 콘크리트의 내구성에 미치는 영향)

  • Beak, Jong-Myeong;Park, Youg-Keol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.56-63
    • /
    • 2016
  • This experiment was compared and analyzed between the original surface paint through chloride penetration, neutralization, freeze-thaw and chemical corrosion resistance measuring internal structure and volume of voids in order to evaluate the effect of increase in durability of the newly modeled nano synthesized polymer paint painted on concrete surface which results improvement on air permeability to increase the durability of concrete structures. The test result of measuring volume of void and inner structure, concrete, spreaded with nano synthesized polymer paint, showed decreasing trend of pore volume in the range of less than $0.1{\mu}m$ and more than $0.3{\mu}m$. Also, using an electron microscope inside showed tightness of hydration texture. Chloride penetration depth of concrete, painted with nano synthesized polymer paint, was decreased more than 92% compared to non-painted concrete and 70% with water-based epoxy painted concrete. Especially, chemical corrosion resistance test set with aqueous solution of 5% sulfuric acid, non-painted concrete and water-based epoxy painted concrete showed weight loss of 4% after dipping for 12 days. On the other hand, concrete painted with nano synthesized polymer paint showed 1.7% weight loss under the same condition. Also, it showed great result of appearance under the criteria of Tsivilis et al.

Properties of Water-Based Paint According to the Mixing Ratio of Powdered Activated Carbon (분말활성탄 혼입률에 따른 수성도료의 특성)

  • Choi, Byung-Cheol;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.48-49
    • /
    • 2020
  • Recently, as people's interest in environmental pollution increases, interest in indoor air pollution as well as outdoors is increasing. Accordingly, this study prepares functional paints by mixing powder activated carbon, which is a porous material, into aqueous paints, and examines the adsorption performance of volatile organic compounds (VOCs) and formaldehyde (HCHO). As a result of the experiment, the concentration of volatile organic compounds (VOCs) and formaldehyde (HCHO) tended to decrease as powder activated carbon was incorporated. It is believed that physical adsorption was achieved by the micropores of powdered activated carbon. However, in the adsorption test method, it is judged that the concentration was affected by the inflow of outside air as the chamber cover was opened to put the test object in the empty chamber where a certain concentration was maintained.

  • PDF

Adsorption of Formaldehyde by Wood Charcoal-Based Building Materials (목탄계 건축자재에 의한 포름알데히드 흡착)

  • Lee, Oh-Kyu;Choi, Joon-Weon;Jo, Tae-Su;Paik, Ki-Hyon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.61-69
    • /
    • 2007
  • The building materials used for improving indoor air quality, the wood charcoal mixed with cement mortar or natural water paint were examined for their potential removing ability of formaldehyde. After the reaction of samples with formaldehyde in the glass flasks designed in our lab, the remaining formaldehyde was collected using DNPH (2,4-dinitrophenyl hydrazine) cartridges, and their concentration was determined using HPLC. From the results, it was found that the removing amount of formaldehyde per one gram sample containing 5, 10, or 15% of wood charcoal was more than three times compared to that of control (100% cement mortar or water paint). Their elimination percentages from the initial formaldehyde was about 80~90%. The experimental results for wood charcoal-water paint showed a similar trend with those of wood charcoal-cement mortar samples. Their elimination percentages from the initial formaldehyde was about 90%. It is proposed that formaldehyde is adsorbed on the adsorbed 'O' or 'OH' groups in the graphene layers formed through the re-arrangement of lignocellulose in the wood during the carbonization procedure.

Characteristics study on fire-resistant paint used by TGA-IR (TGA-IR을 사용한 내화 도료의 특성에 관한 연구)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.168-172
    • /
    • 2011
  • The iron frame of building could be collapsed or bent at $500^{\circ}C$. Therefore the fire-resistant paint should be applied for safety. This study performed the comparative analysis to show the characteristics of fireresistant paint. And then 12 products of fire resistant paint and 6 products of paints were used as samples. And the samples were analyzed by TGA (Thermogravimetric Analyzer) as analyzer for measuring the variation of weight on temper of weight by heating. When TGA analyzer could measure the variatiature, and FT-IR was measured for analyze gas components on variation on of weight by heating on 12 products of fire resistance, the samples showed to decrease 40% of weight to $800^{\circ}C$, and because paints had 50% to 40% of loss weight, it showed to be equal with loss weight of fire resistance paint on high temperature or was lower loss weight than it of fire resistance paints. However number 6 sample of fire resistance paints could show to decrease 20% of total weight on $800^{\circ}C$. And then in the case of FT-IR, fire resistance paints could show to have the high intensity of $CO_2$ spectrum as complete combustion. However paints could show to have the lower intensity of $CO_2$ spectrum, have the higher intensity of water spectrum. Therefore the TGA graph of result could be much different until $250^{\circ}C$. When it was burned, FT-IR spectrum could show to confirm the characteristics of fire resistance paints, and the characteristic could be confirmed on inorganic paint of fire resistance by weight loss of TGA.

Quantitative Visualization of Dissolved Oxygen Concentration Field in Micro Flows using PtOEP/PS Membrane (마이크로 유동에서 PtOEP/PS 박막을 이용한 용존 산소 농도장의 정량적 가시화)

  • Song, Dae-Hun;Kim, Hyun-Dong;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • It is highly needed to measure the dissolved oxygen (DO) concentration field in water for a variety of purposes such as biological, industrial, environmental monitoring and medical application. Application of PSP (Pressure Sensitive Paint) which is sensitive to oxygen concentration has been carried out to measure DO concentration field using PtOEP/PS film and intensity based method under the UV-LEDs illumination. A micro round water jet having 100% of DO was obliquely impinged on to a PtOEP/PS film coated plate placed in a 0% of DO water container. DO concentration fields on the impinging plate were quantitatively visualized with a $2.94\;{\mu}m$ of spatial resolution. Through pixel-by-pixel calibration, uncertainty of each pixel by different sensitivity, different dye concentration and non-uniformity of illumination was removed. It is demonstrated that the high DO concentration region was coincided with the impingement area. The DO concentration gradient due to DO diffusion was affected by Reynolds number.

A Study on the Electromagnetic Shielding of Conductive Powder (도전성(導電性) 분체(粉體)의 전자차폐(電磁遮蔽)에 관한 연구(硏究))

  • Kim, Dong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.244-249
    • /
    • 2004
  • In this paper, shielding effectiveness(SE) of the shielding paint of electromagnetic(EM) waves was investigated with actual experiments. The shielding paint used in this study were made of powder of conductive materials - Ag, Cu, Al, Sn, Ni. Cr, Graphite and Charcoal etc. with a solubility in oil and water. Also, the paper was used as a base sheet. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that silver, copper, nickel were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of density of particles on the SE were studied about the EM shielding paint. The SE strongly depended on the electric resistance by density of painting particles. SE increased as the density of particles was increasing.

  • PDF

Endocrine Disrupting Effects of the Industrial Wastewater Effluents Discharged from the Treatment Plant (산업폐수처리장 방류수의 내분비계 장애작용 평가)

  • Oh Seung-Min;Kim Gi-Suh;Ryu Byung Taek;Jang Hyung Seog;Lee Hee-Sung;Chung Kyu-Hyuck
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.4
    • /
    • pp.375-382
    • /
    • 2004
  • This study was designed to investigate potential endocrine disrupting effects of several industrial wastewater effluents discharged from cosmetic, plaiting, paint, textile industry using EROD bioassay and E-Screen assay. The results of E-screen assay showed that textile industrial wastewater could act as a full agonist and cosmetics and plaiting industrial wastewater could act as a partial agonist. On the contrary, the wastewater discharged from paint industry did not show any estrogenic effect. Estrogenic activity in the effluents of cosmetic and paint industrial wastewater was lower than that in the influents indicating that the wastewater treatment process minimized the effects of discharges on water quality. Despite of these results, it was recognized that wastewater treatment was not always minimize toxic impact. In this study, increased estrogenic effect was observed in the effluents of plating and textile wastewater, and EROD activity was increased in the effluents of cosmetic and plating wastewater.