• Title/Summary/Keyword: Water-meter

Search Result 641, Processing Time 0.033 seconds

Error Check Algorithm in the Wireless Transmission of Digital Data by Water Level Measurement

  • Kim, Hie-Sik;Seol, Dae-Yeon;Kim, Young-Il;Nam, Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1666-1668
    • /
    • 2004
  • By wireless transmission data, there is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error check algorithm in order to decrease the data's distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error check algorithm for error check of transmission data. This study is also that investigation and search for error check algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro process in the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which can get permission to use by Frequency Law made by Korean government

  • PDF

A Review of Ocean Circulation of the East/Japan Sea (한국 동해 해수순환의 개략적 고찰)

  • 김종규
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.103-107
    • /
    • 2001
  • The major studies of an ocean circulation of the East/Japan Sea related to evaluate the feasibility and utilization of deep ocean water are reviewed. The major feature of surface current system of the East/Japan Sea is an inflow of the Tsushima Warm Current through the Korea/Tsushima Strait and the outflow through the Tsugaru and Soya Straits. The Tsushima Warm Current has been known to split into two or three branches in the southern region of the East/Japan Sea. In the cold water region of the East/Japan Sea, the North Korean Cold Current turns to the east near 39$^{\circ}$N after meeting the East Korean Warm Current, then flows eastward. The degree of penetration depends on the strength of the positive wind stress curl, according to the ventilation theory. Various current meter moorings indicate strong and oscillatory deep currents in various parts of the basin. According to some numerical experiments, these currents may be induced by pressure-topography or eddy-topography interaction. However, more investigations are needed to explain clearly the presence of these strong bottom currents. This study concludes the importance of topographical coupling, isopycnal outcropping, different wind forcing and the branching of the Tsushima Warm Current on the circulation of the East/Japan Sea.

  • PDF

Evaluation of Growth Diagnosis in Rice Field using Spectral Characteristics, LAI, and SPAD (분광반사특성과 엽면적지수 및 SPAD를 이용한 벼의 성장단계별 생육상태의 평가)

  • Park, Jong-Hwa;Shin, Hyoung-Sub;Park, Jin-Ki
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.805-809
    • /
    • 2008
  • Measurement of leaf area index (LAI) is useful for understanding rice growth, water use, and canopy light interception. The top nitrogen content(TNC) per unit area is an important quantitative index of the condition of nitrogen nutrition in rice production. The rapid and simple method of estimation of TNC, with the use of the existing nondestructive analyzing instruments chlorophyll meter SPAD-502 and plant canopy analyzer (PCA) LAI-2000, was scrutinized. Destructive measurement is time consuming and labor intensive. Our objective was to evaluate sampling procedures using the Li-Cor LI-1800, LAI 2000 plant canopy analyzer (PCA) for nondestructive estimation of rice LAI, and SPAD-502 on the Northern Plains of Cheongju. The LAI estimated by PCA tended to underestimate the LAI determined by actual measurement by about 20%. The estimation of LAI by PCA was judged to have a sufficient accuracy as a practical technique. A high positive correlation was obtained between the values of the SPAD reading and LAI. NDVI and LAI also showed a very high correlation. The values of the SPAD reading and LAI, and NDVI gave a high positive correlation. These results indicated that the method described in this study was effective as a simple and rapid method for the estimation of rice growth.

  • PDF

A Study on the Zeta Potential Measurement and the Stability Analysis of Nano Fluids using a Particle Image Processing System (입자 영상 처리 시스템을 이용한 콜로이드 입자의 제타포텐셜 측정 및 나노유체 분산 특성 연구)

  • Lee, J.K.;Kim, S.C.;Kim, H.J.;Lee, C.G.;Ju, C.H.;Lee, L.C.
    • Journal of ILASS-Korea
    • /
    • v.8 no.1
    • /
    • pp.16-22
    • /
    • 2003
  • Zeta potential measurements of colloid particles suspended in a liquid are performed by a Zeta Meter developed. There are many applications of colloid stability in spray technology, paints, wastewater treatment, and pharmaceuticalse. Zeta potentials of charged particles are obtained by measuring the electrophoretic velocities of the particles using video enhanced microscopy and image analysis program. The values of zeta potential of polystyrene latex(PSL), $silica(SiO_2)$M, polyvinylidence difluoride(PVDF), silicon nitride, and alumina particles in deionized (DI) water were measured to be -40.5, -31.9, -25.2, -15.1 and -10.1mV, respectively. The particles having high zeta potential less than -20 mV are stable in DI water, because the double layers of them have strong repulsive forces mutually, and the particles having low zeta potential over -20mV are unstable due to Van Der Waals forces. Silica(>20nm), PSL, aluminum and PVDF particles were found to be stable that would remain separate and well disperse, while silicon nitride and alumina particles were found to be unstable that would gradually agglomerate in DI water.

  • PDF

Carbonation of Circulating Fluidized Bed Combustion Fly Ash with Hybrid Reaction

  • Lee, Ki Gang;Bae, Soon Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.2
    • /
    • pp.160-165
    • /
    • 2018
  • This paper investigates the reaction rate of $CO_2$ storing carbonation hybrid reaction by comparing the behavior of carbonation between $Ca(OH)_2$ and fly ash with that of CFBC (Circulating Fluidized Bed Combustion) containing plenty of Free-CaO. Because fly ash with CFBC contains a lot of unreacted CaO, it cannot be used as a raw material for concrete admixtures and its usages are limited. To reuse such material, we stabilized unreacted CaO by carbonation and investigated the carbonation rate. We used a pH meter and a thermometer to check the rate of the carbonization. Also, we set the contents of fly ash with CFBC, $Ca(OH)_2$, flow and fluid of $CO_2$, respectively, to 100 g, 50 g, 100 ~ 1000 cc/min and 400 g based on the content of Free-CaO. We used carbonated water instead of water, and added an alkaline activator to promote the carbonation rate. As a result, the addition of the alkaline activator and carbonated water promoted the rate of carbonation via a hybrid reaction.

A Study on the Optimum Design for a Solar Domestic Hot Water System (小規模 太陽熱 給湯시스템 의 最適設計 에 관한 硏究)

  • 서정일;이영수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.6
    • /
    • pp.517-525
    • /
    • 1984
  • This paper presents a typical solar domestic hot water system and estimates their performances with variance of collector size, storage volume, collector tilt and other factors. The analysis is performed by th computer simulation for which conceptual system against 8760 hourly solar intensities and ambient temperature for a model year stored in the computer has been running. System performance is analyzed on hourly, monthly and yearly basis respectively and at the same time, the economics of various systems are evaluated. And also, this paper shows how an optimized design can be selected for any locality for which solar data and collector performance are provided. The results of this study are as follows. (1)Storage volume of 45 liter per square meter of solar collector lead to the best design. (2)Tilting the collectors to the same angle of the latitude is generally the best (3)Optimal size of collector is approximately 6.68-8.35m$^{2}$ when the latitude is 37.6 .deg. N and storage volume is 300 liter. (4)The performances of a solar domestic hot water system does not depend on the hourly usage but the daily usage.

A Study of Fly Ash Resistivity Characteristics Generated from the Coal Fired Power Plant as a Function of Water Concentration and Temperature (석탄 화력발전소에서 발생되는 석탄회의 수분함유량 및 온도에 따른 비저항성 특성 연구)

  • Ku, Jae-Hyun;Lee, Jung-Eun;Lee, Jae-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.526-532
    • /
    • 2000
  • Recent studies have been directed toward obtaining a better understanding of the application of electrostatic precipitators to collect fly ash particles produced in a coal-fired power plant. Electrical resistivity can be described as the resistance of the collected dust layer to the flow of electrical current and is an important property for the collection efficiency in the electrostatic precipitator. In this paper, fly ash resistivity as a function of temperature up to $450^{\circ}C$ has been experimentally investigated using the resistivity meter consisted of the movable electrode, dust cup, and furnace. Resistivity was found to increase with increased temperature up to $200^{\circ}C$ due to the reduction of water concentration and then gradually decrease with increased temperature due to the activation of electrons. As the resistivity of fly ash in the flue gas temperature of $150^{\circ}C$ was measured >$10^{10}$ ohm cm, the efficiency of fly ash removal in the electrostatic precipitator might be expected to be low due to back-corona phenomenon. Flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash as required.

A Study on the Various Characteristics of Ultrasonic-Energy-Added W/O Type Emulsified Fuel ( I ) - attaching importance to stability and spray characteristics - (초음파에너지 조사 W/O type 유화연료의 제반특성에 관한 연구(I) - 안정성 및 분무특성을 중심으로 -)

  • Kim, Yong-Cheol;Song, Yong-Sik;Ryu, Jeong-In
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.22-28
    • /
    • 2004
  • This study is concerned about the characteristics of ultrasonic-energy-added W/O type emulsified fuel. The distilled water was mixed with diesel oil by using ultrasonic energy fuel feeding system and then the SMD of sprayed droplets was measured to find out atomization characteristics of emulsified fuel by using the Malvern 2600 system. The capacitance value was measured to verify stability of the same specimen by using the digital LCR meter, EDC1630 additionally. The main results are as follows; 1) The more measuring distance increases between one hole nozzle tip and analyser bearm, the more SMD increases. 2) The more water content increases, the more capacitance value increases depending on the time. Main Parameters of the study are the amount of water content $0{\sim}30%$ by 5% in emulsified fuel, and the measurement distance, $20{\sim}140mm$ by 10mm or 20mm between nozzle tip and analyser beam.

  • PDF

Characteristics of Metal Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms (주차장 및 교량 강우유출수의 중금속 오염물질 특성과 동적 EMCs)

  • Kim, Lee-Hyung;Lee, Seonha
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.385-392
    • /
    • 2005
  • The control of nonpoint source pollution is essentially needed to successfully perform the Total Maximum Daily Load program. Of the various land uses in the nonpoint source, the paved areas such as a parking lot and a bridge are stormwater intensive land uses because of high imperviousness and high pollutant mass emissions. This research was performed to understand the magnitude and nature of the stormwater emissions with the purposes of quantifying stormwater pollutant concentrations and mass emission rates from a parking lot and a bridge. Two monitoring sites in Kongju city were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the data such as rainfall, water quality and runoff flow rates. This paper will summarize the metal concentration changes during the storm duration and metal EMCs to characterize the concentration profiles in a parking lot and a bridge. Also a new concept, dynamic EMC, will be proposed to find the relationship between EMC and first flush effect. It can be used to determine the economical treatment criteria in best management practices.

Characterization of carbon nanofluids applicable to heat transfer fluids (열전달 유체 적용을 위한 카본 나노유체 특성 분석)

  • Kim, Doo-Hyun;Hwang, Yu-Jin;Kwon, Yeoung-Hwan;Lee, Jae-Keun;Hong, Dae-Seung;Moon, Seong-Young;Kim, Soo-H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.538-541
    • /
    • 2008
  • The carbon laden suspensions in water with no surfactants have poor stability caused by the hydrophobic layer of particles. In this study, the water-based carbon nano colloide(CNC) was successfully produced using electro-chemical one-step method without agent. The properties of CNC were characterized by using various techniques such as particle size analyzer, TEM, FT-IR, turbidity meter, viscometer, and transient hot-wire method. The average size of the suspended in the CNC was 15 nm in diameter. The thermal conductivity of CNC compared with water was increased up to 14% with 4.2wt% concentration. The CNC was stable over 600hr. The enhanced colloidal stability of CNC may be caused by the chemical structures, such as, hydroxide and carboxyl groups formed in outer atomic layer of carbon, which (i) made the carbon nanofparticles hydrophilic and (ii) prevented the aggregation among nanoparticles.

  • PDF