• Title/Summary/Keyword: Water-meter

Search Result 642, Processing Time 0.04 seconds

Analysis of Field Observations on Characteristics of Stage-Discharge Relationshiup for Yangsan River (양산천 수위-유량관계 특성에 관한 현장관측 분석)

  • 이용희;이상배
    • Journal of Korean Port Research
    • /
    • v.14 no.1
    • /
    • pp.107-114
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial in 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372H$^2$, which is discovered to be most excellent among other curves in reliability analysis. The observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and reproduction of discharge by the induced curve was investigated and compared with the computational results. The rating curve of Yangsan river shows characteristics of Yangsan river more accurately compared with those separated in terms of water levels.

  • PDF

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve (배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구)

  • Oh, C.;Mun, S.B.;Son, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

미터인 회로와 미터아웃회로를 이용한 수압시스템의 특성에 관한 연구

  • 양창문;윤영원;박명관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.91-91
    • /
    • 2004
  • 유압시스템은 1795년 J. Bramah가 물을 작동유체로 사용한 Press를 개발해 사용한 이래 2세기 이상 인간생활의 다양한 분야에 이용되어 왔다. 초기 유압시스템은 쉽게 구할 수 있고, 저장이 용이한 물을 작동유체로 사용하였다. 그러나 물은 부식성, 낮은 점성계수로 인한 저 윤활성과 많은 누설량, 그리고 저온에서의 동결 등과 같은 문제점을 가졌다. 당시에는 물에 대한 부식성이 없는 재료나 물의 누설을 막을 수 있을 만큼의 가공기술이 부족하였으므로 이러한 물의 문제점을 해결하기 위해 1906년 Wiliams와 Janney가 물 대신 기름을 작동유체로 사용하기 시작했다.(중략)

  • PDF

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube (밀폐튜브 내 저온 PCM의 잠열측정법)

  • 류경용;박창현;백종현;홍회기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

Application of Image Technique and Optical Fiber Sensor for Air-water Mixture Flow (기포흐름 측정을 위한 영상기법 및 광섬유센서 적용)

  • Ryu, Yonguk;Jung, Tae-Hwa
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.535-543
    • /
    • 2015
  • Measurements of multiphase flows containing bubbles have been limited because most existing methods target one phase flows. Especially, multiphase flows with a high void ratio have been rarely successful in measurements due to the sudden change of density and thick interfaces between air and water. This study introduces two methods that are capable of measuring flow fields regardless of bubble void ratio, named bubble image velocimetry and bundle fiber optic flow meter. The calculation of the depth of field is suggested to reduce and estimate errors by perspective image velocimetry. The bundle fiber optic flow meter is designed to increase a measurement rate using many optical fibers with a thin diameter. The two methods measured bubble plumes to test reliability and the velocity measurements show good agreement. In addition a hydraulic jump, one of the multiple flows in rivers was measured to test applicability of the methods.

Evaluation of Friction and Hydroplaning Characteristic in Aifield Using Dry Grooving Method (건식그루빙을 사용한 공항 활주로의 마찰 및 수막현상 특성평가)

  • Park, Tae-Soon
    • International Journal of Highway Engineering
    • /
    • v.3 no.3 s.9
    • /
    • pp.111-118
    • /
    • 2001
  • Since the advent of turbojet aircraft with their greater weight and high landing speed breaking performance on runway surface has become un critical. Under certain weather conditions(wet weather, winter) hydroplaning or unacceptable loss of traction can occur, resulting in poor braking performance and possible loss of directional control. To address this concern a number of research project me conducted by NASA, FAA, USAF. The various method which was reported the advantage of the increasing the friction and decreasing the hydroplaning effect. A-2 section of inchon international airport was grooved using drying grooving method. In order to evaluate the effectiveness of the dry grooving method the surface was spray with water and measured the fiction factor and the depth of the water using Mu meter and water depth measuring device. The field test results shooed that the fiction factor nos increased and the depth of the water decreased. The dry grooving method illustrated the reduction of hydroplaning and also, no distress on the runway.

  • PDF

Accuracy Analysis for Velocity Measurement of Microwave Water Surface Current Meter Considering Yaw Angle and Illuminated Area (편각과 측정영역을 고려한 전자파표면유속계의 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.100-100
    • /
    • 2016
  • 전자파표면유속계는 대표적인 비접촉식 계측기기로 최근 유량조사를 위해 활발하게 활용되고 있다. 국내에서 사용되고 있는 전자파표면유속계는 평수기 저유속에서도 측정이 가능하고 편각 측정이 가능하도록 개발되어 한 측정 지점에서 다 지점의 유속이 측정이 가능해 평수기 홍수기에 비교적 적은 인원으로 빠른 시간에 유량측정이 가능하다. 하지만 국내의 경우 전자파표면유속계가 과연 얼마만큼의 정확한 유속을 측정하는지에 대한 분석이 다소 부족한 실정으로 특히, 실제 하천에서 정확한 분석은 수행되지 않은 상태에서 유량 측정에 사용되고 있다. 전자파표면유속계를 실제 하천에서 사용할 경우 발생 할 수 있는 오차의 요인으로는 교량과 같이 높은 지점에서 측정을 수행할 경우 측정영역(Footprint or Illuminated area)에 따른 오차가 발생할 수 있는 가능성이 있고, 동일 측정 지점에 대해 수직각과 편각에 변화에 따른 유속 측정 오차가 발생할 수 있다. 이에 본 연구에서는 국내에서 개발된 Mutronics사의 전자파표면유속계(MWSCM; Microwave Water Surface Current Meter)에 레이저포인터를 부착하여 표면유속 약 0.5m/s ~ 1m/s의 자연 하천과 매우 유사한 실제 소하천 규모의 한국건설기술연구원 안동실험센터 직선하천에서 수직각(Tilt angle) 및 편각(Yaw angle)을 변화시켜가며 유속를 측정하였다. 그리고 측정된 결과를 활용하여 수직각과 편각의 변화에 따른 전자파표면유속계의 측정영역을 검토하였고, 동일한 측정 지점에 micro-ADV를 이용해 측정된 연직유속분포를 외삽하여 산정된 표면유속과 비교하여 전자파표면유속계의 측정 정확도를 분석하였다. 분석결과, 수직각(Tilt angle) 15도 이하에서는 유속 측정의 정확도가 떨어지는 것으로 나타났고, 편각(Yaw angle)이 커질수록 측정영역이 커지게 되어 변동 계수가 증가하는 것으로 나타났다. 그리고 전자파표면유속계의 측정 오차는 측정영역에 민감하게 반응하는 것으로 나타나 실제 전자파표면유속계를 이용한 유량측정 시 측정영역을 고려한 측정이 수행되어야 할 것으로 판단된다.

  • PDF

Experiments on the Submarine Cable Protection Methods Considering the Connection Type (체결형상을 고려한 해저케이블 보호공법에 관한 실험)

  • Yoon, Jae Seon;Ha, Taemin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.329-329
    • /
    • 2017
  • In this study attempted to evaluate the stability of the protection methods by examining hydraulic characteristics of the area around the point in which marine cable protector is installed such as surf zone occurrence point of shore-end submarine cables suitable for coastal marine environmental conditions, flow rate t the tope of the protector and maximum wave height, and to provide basic data for the selection of the optimal protection method. In performing hydraulic model experiments, the topography of submarine cable installation location was reproduced in 2-D sectional channel, and models appropriate for experimental scale and similitude law were produced and installed for each condition of submarine cables and protectors. Since the topography and submarine cable protectors were reproduced and installed in 2-D sectional channel, the exact reproduction of surf and transformation in shallow water zone was possible, and thus the physical properties could be clearly analyzed. For stability review, an experiment to examine the stability was conducted using a wave maker with 50-year frequency design waves as target, and wave height and cycles were applied based on the approximate lowest low water level(Approx. L.L.W), which is the most dangerous in submarine cable protection methods. As for experimental time, typhoon passing time in summer (about 3 hours) was applied, and wave patterns and deviation ratio of the submarine cable protector were investigated after making irregular waves corresponding to design waves. In addition, current meter and wave height meter were installed at the installation location of the submarine cable protector, and the flow rates and wave height at the top of the protector were measured and analyzed to review hydraulic properties.

  • PDF

Estimation of Mean velocity conversion coefficient for measuring Microwave water surface current meter using Drone (드론을 이용한 전자파표면유속계 측정의 평균유속환산계수 산정)

  • Lee, Tae Hee;Kang, Jong Wan;Lee, Ki Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.16-16
    • /
    • 2021
  • 전자파표면유속계(Microwave Water Surface Current Meter)를 이용한 홍수기 유량측정은 교량과 같은 구조물을 이용하여 안전 및 측정위치의 흐름조건 등의 이유로 측정의 한계가 발생한다. 이런 문제점을 개선하기 위해 전자파표면유속계를 드론(Drone)과 결합하여 하천에서의 유량측정에 이용하였다. 전자파표면유속계는 비접촉식 유속측정 장비로 하천의 표면유속을 측정하고 유량산정을 위해 환산계수 0.85를 적용하여 평균유속을 산정하고 있다. 환산계수 0.85는 하천의 각 횡측선 수심-유속분포를 일반적인 분포로 가정하고 표면유속에 0.85를 곱하여 평균유속을 산정한다(Rantz, 1982). 그러나 하천의 측정위치 및 흐름특성에 따라 유속분포가 변화하기 때문에 국외 많은 연구에서 환산계수의 범위를 0.72에서 1.72까지 제시한 바 있다(Johnson and Cowen, 2017). 따라서 환산계수 0.85의 일률적인 적용은 부정확한 유량산정을 초래할 수 있어 측정위치에 적절한 환산계수 산정이 필요하다. 본 연구에서는 2020년 금강의 지류인 봉황천에 위치한 금산군(황풍교) 관측소에서 드론과 전자파표면유속계를 이용해 측정한 표면유속과 ADCP를 이용하여 동시 측정한 평균유속의 비교를 통해 환산계수를 산정하여 평균유속 산정의 정확도를 높이고자 하였다. 전자파표면유속계로 측정한 6개 성과 중 ADCP와 동시 측정한 4개의 성과를 분석하여 환산계수를 산정하였다. 측정성과별 측선수는 16~17개로 홍수터로 월류하여 비정상흐름이 발생한 측선은 제외하고 측선별 환산계수는 0.66에서 1.09의 범위로 나타났고, 성과별 환산계수의 평균치는 0.90에서 0.93 범위로 산정되었다. 환산계수가 일반적인 수치보다 높게 산정된 것은 측정위치 하류 약 600m에 위치한 콘크리트 고정보의 영향이 홍수 시 흐름의 수위-유속분포에 영향을 미쳐 높게 산정된 것으로 판단된다. 따라서 유량산정에 있어 환산계수는 4개 성과에서 산정된 환산계수의 평균치인 0.92를 적용하여 산정하였다.

  • PDF