• Title/Summary/Keyword: Water-hydraulic test

Search Result 532, Processing Time 0.027 seconds

Analysis on Scale Effects to Hydraulic Conductivities in Crystalline Rock (결정질암체의 수리전도도에 대한 규모종속에 관한 분석)

  • 박동극
    • The Journal of Engineering Geology
    • /
    • v.4 no.1
    • /
    • pp.13-28
    • /
    • 1994
  • Hydrogeologic characteristics of crystalline rock including discontinuities is defined by the hydraulic data from the in situ test and by analytical method. Methodology and procedure of the in situ test are used in accordance with test purpose, site condition and characteristics of host rock Hydraulic conductivities in crystalline rock including discontinuifies such as fractured zone and joint, are defined by packer test and slug test. The results indicate Hvorslev' s theory of ground water flow in NX borehole, that the shorter of test interval is, the higher hydraulic conductivity is. This is an indicafion of the fact that the hydraulic rneasured were governed by scale effect of test interval, even at same borehole. According to the result of packer tests in two boreholes, it is understood that hydraulic conductivifies show variations according to the effect of as order of tests. In the comparison of hydraulic conductivifies from both of open borehole tests, the results are relatively well correrated in values. The hydraulic conductivity in the test intervals induding hydrogeologically significant discontinuity shows relatively higher value of hydraulic conductivity in vertical distribution of full depth.

  • PDF

Compressibility and hydraulic conductivity of calcium bentonite treated with pH-responsive polymer

  • Choo, Hyunwook;Choi, Youngmin;Kim, Young-Uk;Lee, Woojin;Lee, Changho
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.329-337
    • /
    • 2020
  • Polyacrylamide (PAM) possesses high water absorption capacity and a unique pH-dependent behavior that confer large potential to enhance the engineering performance of clays. In this study, calcium bentonite was treated with a nonionic PAM. Flexible-wall permeability test and the consolidation test were performed at different pH values to evaluate the effects of PAM treatment on the hydraulic and consolidation properties. Test results demonstrate that index properties are affected by the adsorbed PAM on clay surface: a decrease in specific gravity, a decrease in net zeta potential, and an increase in liquid limit are observed due to the PAM treatment. At a given pH, the compressibility of the treated clay is greater than that of the untreated clay. However, the compression indices of untreated and treated clays can be expressed as a single function of the initial void ratio, regardless of pH. Hydraulic conductivity is reduced by PAM treatment about 5 times at both neutral and alkaline pH conditions under similar void ratios, because of the reduction in size of the water flow channel by PAM expansion. However, at acidic pH, the hydraulic conductivity of the treated clay is slightly higher than the untreated clay. This reflects that the treated bentonite with PAM can be beneficially used in barrier system for highly alkaline residues.

Relation Between Fracture Frequency and Hydraulic Characteristics of Granite in Busan Area (부산지역 화강암의 단열빈도와 수리적 특성의 상관성)

  • 함세영;김문수;류상민;이병대;옥수석
    • The Journal of Engineering Geology
    • /
    • v.11 no.3
    • /
    • pp.279-294
    • /
    • 2001
  • When constructing subsurface structures and drilling wells, the precise hydraulic parameters must be obtained for operating safety and for developing enough quantity of groundwater, respectively. In this study we conducted water injection test at different depths on six boreholes drilled in the granite of Mt. Geumjeong. Hydraulic conductivity was calculated using Moye and Hvorslev methods. The relation between hydraulic conductivity and fracture frequency data obtained from acoustic televiewer and core log was analyzed. From the result, though the correlation coefficient between the hydraulic conductivity and the fracture frequency from acoustic televiewer data is higher than that between the hydraulic conductivity and the fracture frequency from core log data on most of the test holes, the correlation coefficient between the hydraulic conductivity and the fracture frequency from the televiewer data is lower than 0.5. This suggests that the hydraulic conductivity of granite in the study area is influenced not only by the fracture frequency but also by various factors of fracture network such as fracture aperture and length, interconnectivity of fractures, fracture orientation and angle, filling material and so on.

  • PDF

Case study comparisons of computational fluid dynamics modeling versus tracer test to evaluate the hydraulic efficiency of clearwell (정수지 내 추적자 실험과 CFD(전산유체역학)의 상관관계 분석)

  • Kim, Tae-Kyun;Choi, Young-June;Jo, Young-Mahn
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.635-642
    • /
    • 2011
  • Hydraulic efficiency was a vital component in evaluating the disinfection capability of clearwell. Current practice evaluates these system based on the tracer test only. In this paper, CFD(Computational Fluid Dynamics) was applied on the clearwell for alternating or supplementing the tracer test. The baffle factor derived from the CFD modeling closely matched the values obtained from full scale tracer testing. And, for suggesting proper numerical model in clearwell; the turbulence model, discretization scheme, convergence criteria were investigated through separate simulation runs. The model validation was conducted by comparing the simulated data with experimental data. In the turbulence model, the realizable ${\kappa}-{\varepsilon}$ model and the standard ${\kappa}-{\varepsilon}$ model were found to be more appropriate than RNG ${\kappa}-{\varepsilon}$ model. The residuals of convergence criteria should be used as not $10^{-3}$ but $10^{-4}$ or $10^{-5}$. In discretization scheme, the difference of simulated values in 1st, 2nd, 3rd upwind scheme was found to be insignificant. Moreover, the result of this study suggest that CFD modeling can be a reliable alternative to tracer testing for evaluating the hydraulic efficiency.

Correlating the hydraulic conductivities of GCLs with some properties of bentonites

  • Oren, A. Hakan;Aksoy, Yeliz Yukselen;Onal, Okan;Demirkiran, Havva
    • Geomechanics and Engineering
    • /
    • v.15 no.5
    • /
    • pp.1091-1100
    • /
    • 2018
  • In this study, the relationships between hydraulic conductivity of GCLs and physico-chemical properties of bentonites were assessed. In addition to four factory manufactured GCLs, six artificially prepared GCLs (AP-GCLs) were tested. AP-GCLs were prepared in the laboratory without bonding or stitching. A total of 20 hydraulic conductivity tests were conducted using flexible wall permeameters ten of which were permeated with distilled deionized water (DIW) and the rest were permeated with tap water (TW). The hydraulic conductivity of GCLs and AP-GCLs were between $5.2{\times}10^{-10}cm/s$ and $3.0{\times}10^{-9}cm/s$. The hydraulic conductivities of all GCLs to DIW were very similar to that of GCLs to TW. Then, simple regression analyses were conducted between hydraulic conductivity and physicochemical properties of bentonite. The best correlation coefficient was achieved when hydraulic conductivity was related with clay content (R=0.85). Liquid limit and plasticity index were other independent variables that have good correlation coefficients with hydraulic conductivity (R~0.80). The correlation coefficient with swell index is less than other parameters, but still fairly good (R~0.70). In contrast, hydraulic conductivity had poor correlation coefficients with specific surface area (SSA), smectite content and cation exchange capacity (CEC) (i.e., R < 0.5). Furthermore, some post-test properties of bentonite such as final height and final water content were correlated with the hydraulic conductivity as well. The hydraulic conductivity of GCLs had fairly good correlation coefficients with either final height or final water content. However, those of AP-GCLs had poor correlations with these variables on account of fiber free characteristics.

Study on vehicle application of biodegradable hydraulic oils from the point of tribological evaluation technology (Tribology 관점에서 생분해성 유압작동유 실적용 평가에 관한 연구)

  • Na ByungChul;Kim JinYong;Seo JoonHo
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.367-371
    • /
    • 2004
  • Bio-degradable hydraulic oil using polyolester base oil is formulated for the applications of heavy duty hydraulic machineries. It has proved quality and market price competitiveness by assessment of reliability test in vehicle manufacturer and specific vehicle related institute. Contribution of bio-degradable oil keep the working environment clean and increase export competitiveness in European market. Leakage or waste of mineral types of hydraulic oils in heavy duty machineries causes pollution of river, ocean, underground water. Drinkable-water pollution is serious problem in Europe. In some European countries, using bio-degradable hydraulic oils become an obligation in heavy duty machineries. New product of bio-degradable oils satisfy the European regulations(OECD 302B) and shows excellent performance in compare with European products.

  • PDF

Application of Three-Dimensional Model to Evaluate Stream Discharge Capacity due to Vegetation (식생분포에 따른 하도의 통수능 검토를 위한 3차원 모형의 적용)

  • Noh, Joon Woo;Lee, Jin Young;Ahn, Ki Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.37-48
    • /
    • 2011
  • Recently, the social and environmental functions of nature river are important due to the increase of expectation for river restoration. So it should be considered the effect of vegetation affecting the conveyance capacity and hydraulic resistance. However, it has not yet proposed a objective standard and modeling method to estimate the effect of conveyance capacity according to vegetaion distribution in the watercourse such as water level or velocity. Therefore, this study simulates the variations of water level and velocity using 3-dimensional hydrodynamic model, EFDC, to consider a conveyance capacity in downstream of the Soyang Reservoir. The simulation results were validated using statistical index such as F-test and T-test. As results, the water level rises about 0.01 to 0.47m and velocity difference are about -0.95m/s to 0.23m/s.

Development and Hydraulic Characteristics of Continuous Block System in River Bank Protection (I) - Development and Application Review through Hydraulic Model Test - (일체형 식생호안블록 시스템 개발 및 수리특성 연구(I) -일체형 호안블록 개발 및 수리모형실험을 통한 적용성 검토-)

  • Jang, SukHwan
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.87-97
    • /
    • 2008
  • This research focused on development and application feasibility for the coalesced continuous block system in river bank protection. Most of block systems in river bank are pre cast type and have some difficulties against high velocity flood condition or high pressure load, however, the continuous block system can be applied to flood damage recover as well as environmental vegetation block system in river bank. For the application review and analysis of hydraulic condition for this block system, hydraulic physical modeling was carried out. The physical model was built as a scale of 1:50 by Froude similitude measuring the water levels and the water velocities for vegetation application or not. In consequence, the water velocities were observed to decrease meanly 10.1%, and the water depths were to increase meanly 17.8% in case of the of design flood, $Q=200m^3/sec$. To verify the hydraulic physical modeling, the numerical modeling should be conducted for a close examination of vegetation application by one or two dimensional numerical analysis as a next study.

  • PDF