• Title/Summary/Keyword: Water-flushing toilet

Search Result 15, Processing Time 0.018 seconds

A Study on Removal of Organic Matter and Chromaticity from Urine Using Chemical Oxidization Process (화학적 산화공정을 이용하여 소변의 색도 및 유기물 처리를 통한 재이용 기술 연구)

  • Shin, Sung-Hoon;Jung, Jong-Tai;Cho, Yong-Chul
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.109-115
    • /
    • 2018
  • This study was conducted to solve the water shortage problem by reclaiming urine from homes or public places and using it as cleaning water for toilets. The process used in this experiment is a chemical oxidation process combining ozone, hydrogen peroxide, and UV. We set the key substance that is to be removed as chromaticity and conducted the experiment to remove it. If the quantity or concentration of injected ozone, UV, and hydrogen peroxide is insufficient, then the chromaticity will initially increase due to low oxidizing power, and will later decrease. In addition, the efficiency of removing chromaticity appeared to be higher, depending on the quantity of ozone injected, for medium concentrated urine than highly concentrated urine. However, the absolute quantity of removed chromaticity was about 68% higher for highly concentrated urine, when 16 g/hr of ozone was injected. The higher the pH level, the reaction time and efficiency of removing chromaticity were higher, and in normal conditions, in reference to a pH of 8.55, there was a 6% difference in efficiency between a pH level of 5.05 and a pH level of 10.12. Finally, when processing urine through an ozone-only process, COD decreased steadily over time, but DOC did not decrease. This is because ozone reacts selectively with organic matter.

Application of Rainwater Harvesting System Reliability Model Based on Non-parametric Stochastic Daily Rainfall Generator to Haundae District of Busan (비모수적 추계학적 일 강우 발생기 기반의 빗물이용시설 신뢰도 평가모형의 부산광역시 해운대 신시가지 적용)

  • Choi, ChiHyun;Park, MooJong;Baek, ChunWoo;Kim, SangDan
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.634-645
    • /
    • 2011
  • A newly developed rainwater harvesting (RWH) system reliability model is evaluated for roof area of buildings in Haeundae District of Busan. RWH system is used to supply water for toilet flushing, back garden irrigation, and air cooling. This model is portable because it is based on a non-parametric precipitation generation algorithm using a markov chain. Precipitation occurrence is simulated using transition probabilities derived for each day of the year based on the historical probability of wet and dry day state changes. Precipitation amounts are selected from a matrix of historical values within a moving 30 day window that is centered on the target day. Then, the reliability of RWH system is determined for catchment area and tank volume ranges using synthetic precipitation data. As a result, the synthetic rainfall data well reproduced the characteristics of precipitation in Busan. Also the reliabilities of RWH system for each of demands were computed to high values. Furthermore, for study area using the RWH system, reduction efficiencies for rooftop runoff inputs to the sewer system and potable water demand are evaluated for 23%, 53%, respectively.

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Development of Wastewater Treatment and Recycle Technology Using a Tubular Ceramic Ultrafiltration Membrane 1, Effect of Periodic Backflushing (관형 세라믹 한외여과막을 사용한 폐수처리 및 재활용기술개발 : 1, 주기적 역세척 효과)

  • 박진용
    • Membrane Journal
    • /
    • v.9 no.3
    • /
    • pp.178-184
    • /
    • 1999
  • A periodic backflushing was performed to reduce the membrane fouling of ultrafiltration for wastewater, and the effect and the optimum condition were investigated in this study. The alumina¬ceramic tubular membrane with pore size of 0.02${\mu}m$ was used for the wastewater treated by coagulation and sedimentation from two paper plants, of which A plant made toilet paper by recycling milk paper cartons and B plant recycled corrugated cardboards. And the effect of periodic backflushing to membrane fouling and quality of permeate were studied with a constant backflushing time of 3 sec. As results of measuring SS, TDS, and COD of source and permeate, the rejection rate of SS showed the highest value at the backflushing period of 15 see, which was the shortest time in these experiments, in case of waste¬water discharged from A plant. However, the rejection rate of COD had the highest value at the period of 30 sec for wastewater from both A and B plant. Then, the rejection rate of TDS was almost same at 30 and 60 sec for A plant wastewater, and the highest at 60 see for B plant. The effect of periodic back¬flushing to membrane fouling was investigated by change of permeate flux according to operating time. The permeate flux decreased slowly at the operation with backflushing, and was higher compared with that without backflushing in both case of A and B wastewater. But, the optimum period with the highest flux of A wastewater was different from that of B, because SS and COD of A was higher than those of Band TDS of B was higher than that of A.

  • PDF