• Title/Summary/Keyword: Water-Cooled RF Load

Search Result 1, Processing Time 0.017 seconds

High-Power Water-Cooled RF Load (고출력 마이크로파 수냉식 RF Load 설계)

  • Heo, Ye-Rim;Lee, Cheol-Eon;Park, Su-Yeon;Kang, Ju-Yeong;Choi, Jin Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.6
    • /
    • pp.445-451
    • /
    • 2019
  • This paper presents the design of a water-cooled radio-frequency(RF) load with simple structure, for use in the ultrahigh-frequency (UHF) band. After establishing a formula to obtain the physical properties that affect RF matching, we measure the permittivity and $tan{\delta}$(Loss tangent) of tap water. Because the temperature of tap water increases upon applying high power, we measure the permittivity and $tan{\delta}$ for all changes in the temperature of tap water. In order to reduce the length of the water-load, molybdate with high $tan{\delta}$ is mixed with tap water. The loss tangent of the mixture is found to be approximately 26 times higher than that of tap water. Finally, we manufacture a water-cooled RF load and measure its characteristics. A reflection coefficient of -19 dB and bandwidth of 15 % is obtained at 460 MHz.