• 제목/요약/키워드: Water-Air Tightness

검색결과 18건 처리시간 0.02초

농수산물 및 식품의 지하 저장 (Underground Storage of Food)

  • 신희순;권광수
    • 터널과지하공간
    • /
    • 제4권2호
    • /
    • pp.192-200
    • /
    • 1994
  • Underground offers many advantages for storing agricultural and marine products. Since it is confined by thick walls of rock it is easy to control temperature and humidity and to achieve air and water tightness. Also, damages by rodents and insects could be avoided. Flexibility in choosing the location is another advantage that underground could offer. Consequently the goods could be stored near the big city to meet the demand change. Because of these advantages, many underground food storage facilities were built and operated successfully in U.S. and many Euroupean countries. On the other hand, there is no underground food storage facilities in Korea despite the need is growing rapidly. This paper describes the case studies of foreigh food storage and technologies related to food storage were analyzed and evaluated. Also performed is analysis of domestic technologies for construction and operation of underground food storage facilities to deduce the fields of studies that have to be conducted.

  • PDF

HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발 (Development of Nano Ceramic Structures for HEPA Type Breathing Wall)

  • 김종원;안영철;김길태
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

연료전지 스택의 기밀성 향상을 위한 가스켓 모델링과 해석 기법 (Numerical Modeling of Fuel Cell Gasket for Sealing Performance)

  • 김헌영;김정민;김대영;서정도;양유창;임철호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.97-100
    • /
    • 2007
  • Fuel Cell Stack performance, which is influenced by the maintenance of a constant internal environment, requires high levels of air tightness. Used for analysis, gasket for fuel cell is made of elastic rubber materials and placed over separator, and shape of deformation of a gasket affects the transformation separator and airtightness while fastening structure. Separator as made of steel sheet isn't broken under pressure but can affect gas and cool water flow by the plastic deformation process. Therefore, it is understood that assembly process is well developed in case distribution of stress and shape of deformation is shown uniformly. This study is conducted on the assumption that a fuel cell maintenance is advantageous in that conditions. In this paper, analyses of unit cell and partial model were performed and distribution of stress and shape of deformation of Gasket and separator were analyzed to evaluate the airtightness while fastening structure.

  • PDF

재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가 (Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster)

  • 박병용;조진균;정용대;이원학
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

수상함 격실기밀시험 결과의 신뢰성 확보를 위한 압력 보정 시스템 개발 (Development of Pressure Correction System for Surface Vessel to Ensure Reliability of Compartment Test Result)

  • 민일홍;김준우;손기중
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.409-414
    • /
    • 2021
  • 수상함이 전투 환경에서 우수한 임무수행능력과 생존성을 구현하기 위해서는 구획을 차단하는 수밀/기밀 성능이 중요하다. 위와 같은 요구사항을 충족을 위해 함정 건조 후 시운전에서 구조요소(격실 및 탱크)에 대한 밀폐성과 특정부위에 대한 강도의 적합성을 검사하며, 특히 수선에 인접한 격실들의 격실기밀시험(Air test)을 수행한다. 격실기밀시험은 대상 격실에 공기를 주입하여 시운전 평가서 상의 요구압력까지 압을 적용하고, 일정 시간동안 압력강하 값을 확인하여 해당 구역의 요구조건 충족여부를 판단한다. 검사 기준은 10분 동안 감소된 압력이 시운전 평가서의 압력강하 허용치 이내이어야 한다. 하지만 외기온도의 영향이 큰 여름철에 격실기밀시험 진행 간 유입되는 열이 내부 공기의 온도를 상승시키고, 이로 인해 공기가 팽창하여 격실 내 압력이 증가하는 현상이 식별되었다. 이러한 현상은 격실기밀시험에서 최종 압력강하 값을 정확히 판단할 수 없게 하고 평가결과에 대한 신뢰성을 결여시킬 수 있다. 본 연구를 통해 격실 내 온도변화 영향을 보정하기 위한 시스템을 고안하였다. 개발된 시스템은 격실 내 온도변화에 의한 압력 변화량을 계산하여 보정값을 출력한다. 이상기체 방정식을 통해 압력변화량을 계산하며, 격실기밀시험 간 온도유지 및 증가/감소를 반영할 수 있도록 개발되었다. 계산된 압력 보정값을 NIST REFPROP의 데이터 베이스와 비교하였을 때, 최소 0.126 %에서 최대 0.253 %의 차이를 보였다.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

나노합성 무기질 폴리머계 표면처리제가 콘크리트의 내구성에 미치는 영향 (The Influence of Nano Synthesized Polymer Paint on Durability of Concrete)

  • 백종명;박용걸
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.56-63
    • /
    • 2016
  • 콘크리트 구조물의 내구성을 향상하기 위해 개발된 통기성이 개선된 나노합성 폴리머 표면처리제를 도포한 콘크리트의 내구성향상 효과를 평가하기 위해 내부 구조와 공극량을 측정하였으며, 염분침투, 탄산화, 동결융해 및 화학적 침식 저항성에 대한 실험을 진행하여 기존 표면처리제와 비교 분석하였다. 공극량과 내부 구조를 측정한 결과, 나노합성 폴리머 표면처리제를 도포한 콘크리트는 $0.3{\mu}m$ 이상의 공극과 $0.1{\mu}m$ 이하의 공극영역에서 세공량이 감소하는 경향을 보였으며, 전자현미경을 통한 촬영된 내부는 수화조직에 의해 치밀함을 보였다. 나노합성 폴리머 표면처리제를 도포한 콘크리트의 염분침투 깊이는 무도포 콘크리트에 비해 약 92% 이상, 수성 에폭시 표면처리제를 도포한 콘크리트보다도 약 70% 이상 감소하였다. 이는 탄산화, 동결융해 및 화학적 침식 저항성 실험에서도 비슷하게 나타났다. 특히 황산 5% 수용액에 침지 실험한 화학적 침식 저항성 실험에서는 침지 12일 이후 무도포 콘크리트와 수성 에폭시 표면처리제를 도포한 콘크리트에서 -4%의 중량감소를 보였지만, 나노합성 폴리머 표면처리제를 도포한 콘크리트는 -1.7%의 중량감소율을 보였으며, Tsivilis et al.에 의한 외관등급 조사법에서도 우수한 결과를 보였다.

소형 벤로형 유리온실에서 적외선등 난방 시스템의 난방효과 분석 (Analysis of Heating Effect of an Infrared Heating System in a Small Venlo-type Glasshouse)

  • 임미영;고충호;이상복;김효경;배용한;김영복;윤용철;정병룡
    • 화훼연구
    • /
    • 제18권3호
    • /
    • pp.186-192
    • /
    • 2010
  • 경상대학교 농장 벤로형 유리온실($280m^2$)에 적외선등 난방 시스템을 설치하였다. 분식물 호접난, 홍콩야자나무, 무늬고무나무, 장미에 대한 적외선등 난방 시스템의 가열효과를 알아보고자 열화상 카메라를 이용하여 온도변화를 측정하였다. 그리고 난방의 효과를 적외선등 난방시스템 'On'과 'Off'로 달리하여 실험을 수행하였고 적외선등 난방 시스템의 경제성을 분석하였다. 온실 내부 설정온도가 $18^{\circ}C$일 때 식물체의 엽온도는 $22.8{\sim}27^{\circ}C$, 화분에 담겨 있는 배지의 온도는 $21.3{\sim}24.3^{\circ}C$이었다. 관엽식물과 같이 키가 큰 작물은 상부의 온도가 홍콩야자나무와 무늬고무나무 각각 $24.0^{\circ}C$$26.9^{\circ}C$로 가장 높았고, 아래 로 내려오면서 점점 온도가 내려가는 경향을 보였다. 열화상 카메라를 이용한 온도 변화 관찰을 통하여 적외선등 난방 시스템을 이용한 온실내 작물의 가열 효과는 충분함을 알 수 있었다. 장미의 경우 적외선등 난방 시스템을 이용한 난방의 경우 밤과 새벽 사이 외부 기온이 많이 떨어지는 시점에도 설정온도($18^{\circ}C$)에 가깝게 유지되고 있었다. 특히 'On' 상태에서 근권부 평균온도는 $21.8^{\circ}C$이었고, 엽의 평균온도는 $17.8^{\circ}C$이었다. 'Off' 상태의 경우 근권부 평균온도가 $20.4^{\circ}C$이었고, 엽의 평균온도는 $15.5^{\circ}C$로 뚜렷한 차이를 보였다. 난방부하량은 약 $24,850{\sim}35,830kcal{\cdot}h^{-1}$ 정도로서 이 때 난방비를 경유로 환산 하면 약 27,000~40,000원 정도였다. 소비전력량과 전력요금은 각각 330~560 kWh 및 8,600~14,800원 정도였다. 즉 전체적으로 단순비교해 볼 때, 적외선등 난방 시스템을 사용할 경우 경유 온수보일러에 비해 난방비용이 약 35%정도 밖에 소요되지 않는 것을 알 수 있다. 적외선등 난방시스템을 이용한 난방의 경우 야간 시간대에 공기온도가 설정온도 보다는 다소 낮게 유지되고 있음을 알 수 있다. 즉, 유리온실의 경우 밀폐성이 좋지 않아서 공기온도를 설정한 온도수준으로 유지되지 못하는 것으로 판단되어 향후 유리온실에서 적외선등 난방 시스템을 이용하는 경우 설치간격, 센서 부착위치 및 공기대류 등에 대한 연구가 더 필요하다고 생각된다.