• Title/Summary/Keyword: Water velocity

Search Result 3,387, Processing Time 0.031 seconds

X-ray Micro-Imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-Bubbles (X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시 측정기술 개발)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.659-664
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of 20∼60$\mu\textrm{m}$ diameter moving upward in an opaque tube (${\Phi}$=2.7mm) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

Verification and Application of Surface-Velocity Measurement Method Using LSPIV (LSPIV를 이용한 표면유속 측정기법의 검증 및 적용)

  • Kim, Young-Geun;Roh, Young-Sin;Yoon, Byung-Man
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.2
    • /
    • pp.155-161
    • /
    • 2004
  • The purpose of this study is to verify LSPIV technique. Verification was made using moving cart with known velocity. The difference of velocity values obtained using these methods are within 5%, which means that LSPIV can be used in the field with reasonable accuracy After verification, LSPIV was applied to the river. The Neungwon stream and the Gonjiam stream, tributaries of the Kyungan stream, were selected as the test sites for application. The results of the test application were compared with those obtained by 3-D electromagnetic current meter and electron-wave surface velocity meter. Results show that the velocity values obtained using LSPIV coincide well with those obtained using conventional devices with maximum difference of 8%.

Synchrotron X-ray Micro-imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-bubbles (X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시측정)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1744-1748
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}=2.7mm$) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

  • PDF

Study on Performance Evaluation of Oscillating Heat Pipe Heat Exchanger for Low Temperature Waste Heat Recovery

  • Bui, Ngoc-Hung;Kim, Ju-Won;Jang, In-Seung;Kang, Jeong-Kil;Kim, Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.73-81
    • /
    • 2003
  • The performance of heat exchanger using oscillating heat pipe (OHP) for low temperature waste heat recovery was evaluated. OHP used in this study was made from low finned copper tubes connected by many turns to become the closed loop of serpentine structure. The OHP heat exchanger was formed into shell and tube type. R-22 and R-141b were used as the working fluids of OHP with a fill ratio of 40 vol.%. Water was used as the working fluid of shell side. As the experimental parameters, the inlet temperature difference between heating and cooling water and the mass velocity of water were changed. The mass velocity of water was changed from 30 kg/$m^2$s to 92 kg/$m^2$s. The experimental results showed that the heat recovery rate linearly increased as the mass velocity and the inlet temperature difference of water increased. Finally, the performance of OHP heat exchanger was evaluated by $\varepsilon$-NTU method. It was found that the effectiveness would be 80% if NTU were about 1.5.

Status and Design of Rapid-mix for Mechanisms of Alum coagulation (급속(急速) 혼화공정(混和工程) 현황(現況) 및 개선(改善) 사례(事例) 연구(硏究))

  • Jun, Hang-Bae;Han, Kyung-Jeon;Lee, Tae-Yong;Son, Kwang-Ik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.4
    • /
    • pp.97-106
    • /
    • 1995
  • An improving example for traditional rapid mix system was studied in the base of mechanisms of alum coagulation. Local status of the major water treatment plants was also investigated and evaluated for upgrading these plants. A new design and operating criterium for rapid mix system was proposed to velocity gradient, G of $1,000-1,500sec^{-1}$ and detention time, t of 1 sec from the results of experiments and literature reviews. Comparing the present rapid mix system to this criterium, apparent difference existed between them. In this study, for improving Seongnam water treatment plant, a design criterium of velocity gradient, and detention time was set to $1,100sec^{-1}$, 1 sec, respectively. A new rapid mix system adopted the nozzle injection countcurrently cross the inlet pipe to the whole area. The injection velocity was 17m/s, nozzle diameter was 1.0mm, and number of nozzle was 70. The new modified system without running present four 75 HP agitators was able to improve water quality(based on sedimentation effluent) by 15-35% and to reduce electrical energy by 98%.

  • PDF

Numerical Simulation for Dry Deposition Velocity of Ozone According to Land-use Types (지표면의 종류에 따른 오존의 건성침적속도에 관한 수치모의)

  • 이화운;노순아;문난경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.583-594
    • /
    • 2003
  • Ozone is an important atmospheric pollutant that is occurred in tropospheric chemical process and it also affects the human health and plants. For a correct application of abatement strategies for ozone, it is necessary to understand the factors that control atmospheric ozone removal by dry deposition processes. The present study investigates the numerical simulation of the dry deposition velocity (V$^{d}$ ) obtained from PNU/DEM (Pusan National University Deposition Model). PNU/DEM includes seasonal categories, meteorological factors, surface properties and land-use types and proposes for an accurate numerical computation. And, this study examines the ability of the PNU/DEM to compute V$_{d}$ of ozone over water surfaces and evaluates PNU/DEM by comparing its estimated V$_{d}$ to past observed V$_{d}$ over water. The parametrization was found to yield V$_{d}$ values generally in good agreement with the observations for the deciduous forest and the coniferous forest. Ozone is removed slowly at wet surface or water due to its low water solubility. Therefore V$_{d}$ values over water were lower than Vd values over the other surfaces. Comparison of PNU/DEM simulated V d values to observations of ozone V$_{d}$ that have been reported in the literature implies that PNU/DEM produces realistic results.

Investigation on the Liquid Water Droplet Instability in a Simulated Flow Channel of PEMFC (고분자전해질형 연료전지의 유로 채널 모사를 통한 단일 액적의 불안정성 관찰)

  • Kim, Bo-Kyung;Kim, Han-Sang;Min, Kyung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.93-98
    • /
    • 2008
  • To investigate the characteristics of water droplet on the gas diffusion layer from both top-view and side-view of the flow channel, a rig test apparatus was designed and fabricated with prism attached plate. This experimental device is used to simulate the growth of single liquid water droplet and its transport process with various air flow velocity and channel height. The contact angle hysteresis and height of water droplet are measured and analyzed. It is found that droplet tends towards to be instable by decreasing channel height, increasing flow velocity or making GDL more hydrophobic. Also, the simplified force balance model matches with experimental data only in a restricted range of operating conditions and shows discrepancy as the air flow velocity and channel height increases.

Development of Multi-Sensor based River Monitoring Technology for River Flood Risk surveillance (하천 홍수 위험 감시를 위한 다중센서 기반 하천 관측 기술 개발)

  • Jang, Bong-Joo;Jung, In Taek
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.11
    • /
    • pp.1372-1382
    • /
    • 2020
  • This paper proposes a core technology for a micro river monitoring terminal device suitable for flood monitoring in small rivers and valleys. Our proposed device is basically equipped with a 77GHz radar, gyro and accelerometer sensors. To measure the flow velocity and water level, we proposed a signal processing technique that extracts pure water energy components from the observed Doppler velocity and reflection intensity from the radar. And to determine the stability of the river structure equipped with our device, we constantly monitor the displacement of the measured values of the gyro and accelerometer sensors. Experimental result verified that our method detects pure water energy in various river environments and distinguishes between flow velocity and water level well. And we verified that vibration and position change of structures can be determined through a gyro sensor. In future research, we will work to build a secure digital twin river network by lowering the cost of supplying RF-WAV devices. Also we expect our device to contribute to securing a preventive golden time in rivers.

Computational Fluid Dynamics Simulation of Flow Pattern Change in the Andong-Imha Reservoir Connecting Tunnel Due to Fish Exclusion Screens (어류 차단 스크린 설치에 따른 안동-임하호 연결터널 내 흐름변화에 대한 전산유체동역학 수치모의)

  • An, Sangdo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.477-485
    • /
    • 2014
  • Imha Reservoir is connected to Andong Reservoir via a diversion tunnel allowing water to pass between. The diversion tunnel is equipped with screens to exclude exotic largemouth bass due to their predatory impacts on prey assemblages resulting in a degradation of species richness of local fish fauna and extinction of local fish populations in Korea. Flow pattern changes resulting from the fish screens and trash racks were investigated using a computational fluid dynamics (CFD) model. Numerical simulations showed that the decrease in the discharge capacity of the tunnel is approximately 8.6% and the headloss coefficient for fish screen at Andong intake tower was determined to be 1.5. In order not to allow the small fishes enough to pass through the wire openings enter into Imha Reservoir through tunnel, the velocity in the tunnel should be greater than 1.48 m/s which is a critical ascending velocity of the bass. This study suggests that it can keep the velocity higher enough to exclude largemouth bass when a gate opens with the condition of 1.0m difference in water stage between two reservoirs.

Measurement of Dry Deposition of Polycyclic Aromatic Hydrocarbons in Jeoniu (전주지역에서 다환방향족 탄화수소의 건식 침적 측정)

  • Kim, Hyoung-Seop;Kim, Jong-Guk;Ghim, Young-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.242-249
    • /
    • 2007
  • Deposition fluxes of polycyclic aromatic hydrocarbons (PAHs) were measured at the Chonbuk National University located in Jeonju between June and November 2002. Fluxes of gaseous and particulate PAHs were separately obtained using a water surface sampler (WSS) and a dry deposition plate (DDP). Most of PAHs were deposited in the gaseous form since the low molecular weight PAHs dominates in the atmosphere. The deposition velocity of particulate PAHs was higher than that of gaseous PAHs when the molecular weight was low, but substantially decreased as the fine particle fraction increased with molecular weight. The deposition velocity was generally higher at high wind speeds. However, increase in the deposition velocity in unstable atmospheric conditions was also observed for gaseous PAHs of intermediate molecular weight.