• Title/Summary/Keyword: Water treatment facility

Search Result 301, Processing Time 0.028 seconds

Development of Road Tunnel Ventilation System with Electrostatic Precipitator (도로터널용 전기집진시스템 개발)

  • Kim, Jong-Ryul;Weon, Jong-Oung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.80-83
    • /
    • 2008
  • As SOC (Social Overhead Capital) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, we may need to introduce a compulsory ventilation system as well as natural ventilation mechanism. The natural ventilation mechanism is enough for short tunnels, meanwhile longer tunnels require a specific compulsory ventilation facility. Many foreign countries already have been devoting on development of effective tunnel ventilation system and especially, some European nations and Japan have already applied their developed tunnel ventilation system for longer road tunnels. More recently, as the quality of life improved, our concerns about safety of driving and better driving environment have been increased. In order to obtain clearer and longer driving view, we are more interested in EP tunnel ventilation system in order to remove floating contaminants and automobile exhaust gas. Evan though it's been a long time since many European countries and Japan applied more economical and environment-friendly tunnel ventilation system with their self-developed Electrostatic Precipitator, we are still dependant on imported system from foreign nations. Therefore, we need to develop our unique technical know-how for optimum design tools through validity investigation and continuous possibility examination, eventually in order to localize the tunnel ventilation system technology. In this project, we will manufacture test-run products to examine the performance of system in order to develop main parts of tunnel ventilation system such as electrostatic precipitator, high voltage power generator, water treatment system, etc.

  • PDF

Study on Change of Microbial Activity and Removal Efficiency of Phosphorus with Alum Injection in the Biological Process (생물학적 처리공정 내 Alum 주입에 따른 인 처리 효율과 미생물 활성도 변화에 관한 연구)

  • Choi, Jung Su;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.188-193
    • /
    • 2011
  • The effects of coagulants on the microorganisms when they are injected directly into the biological treatment facility for T-P removal have been easily observed from the results of past experiments. As such this study is set out to derive the effective plans for the coagulant dosage by analyzing the effects of the injected coagulant on the microbial activity during the chemical treatment for T-P removal. The research methods entailed the assessment of removal efficiency of T-P according to the coagulant dosage while changing the molar ration between Alum and influent phosphorus. At the same time Specific Oxygen Uptake Rate (SOUR) according to the coagulant dosage was measured. SOUR was used as a method for indirect assessment of the microbial activity according to the coagulant dosage. The results from the study showed that with the increase in the alum dosage, the removal efficiency T-P tended to increase. On the other hand, the increase in coagulant dosage resulted in the decrease in SOUR, which indicates the decrease in the microbial activity. Such reduction in the activity could be explained by the increase in the concentration of removal efficiency of $TBOD_5$. Based on experiment results from the study, it is determined that coagulant dosage affects the microbial activity. Moreover, the indirect assessment on the microbial activity using SOUR is considered possible.

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.

Reformation of Environmental Regulation through introduction of the Zero Liquid Discharge System (무방류시스템 도입에 따른 환경규제효율화 방안)

  • Choi, Ji-Yong
    • Journal of Environmental Policy
    • /
    • v.2 no.1
    • /
    • pp.31-49
    • /
    • 2003
  • It is difficult to examine the causal relation of pollution damages because the time gap between pollution cause and effect is large and new pollutants are continuously being produced. Their many environmental effects are not promptly studied. As both the study of causal relation about pollution and the pollutant treatment are becoming highly advanced by the development of science and environmental technology, both the economy and balance on environmental regulation may be discussed. It is reasonable to decide environmental policy in consideration of close relation between both the generation and resolution of environmental problems and of technological developments because environmental problems are related to complicated social problems and scientific technologies. First item in policy decision about environmental control and management is preferentially to consider the way of prevention. It is necessary to prevent pollution by regulating the installment of environmental pollution facility into the environmentally sensitive areas, like water supply source and to regulate land utilization as a method to achieve pollution prevention. Second is a consideration of environmental technology development. This is a solution which can accomplish the development of environmental technology and the reinforcement of economic competition. Third is the coexistence of environment and economy. It is necessary to consider economy in connection with environmental problems and environment in economic problem. Then, we can enjoy a healthy life as well as economic affluence. Fourth is the enlargement of environmental management means. Environmental management means must be diversified because environmental cause and effect are varied. For Improving the land use regulation system, it is necessary to consider both land use regulation status and pollutant toxicity with the development of environmental technology. Land use must be approached by classifying land to 3 levels; water source protection zone and water front zone, special zone 1 and 2, rancus and other zones. Land regulation policy to prevent any accident in water source protection zone, waterfront zone, and special zone must be continuously upgraded. However, economical consideration in other zones is required by the development of environmental technology.

  • PDF

Ecological Restoration Plan for a Small Scale Public Construction Area - A Case Study on Ilsan Water Treatment Plant, Goyang-Si - (소규모 공공시설 개발 사업지의 생태적 복원 연구 - 고양시 일산정수장 조성예정지를 사례로 -)

  • Lee, soo-Dong;Kang, Hyun-Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.6
    • /
    • pp.48-63
    • /
    • 2008
  • This research is to apply suitable natural ecosystem evaluation criteria in order to develop the ecosystem conservation, restoration and ways to build substitute habitats as a compensation plan for damaged soundly natural ecosystems in small-scale projects such as resource recovery facility, filtration, etc. The environmental ecology evaluation i.e. generally based on their actual vegetation, community structure, wildlife, water system survey were measured the primary plans for reflecting unique natural environment level of site. As a result, it is necessary to conserve the land in fallow type of wetland, good conservative condition of deciduous forest, wetlanded watercourse for amphibia and reptiles crossing. However, the plan of filtration plant was destroyed wetland(sound ecosystem), natural forest, asian toad spawning area. According to the result of it schemed to build alternative wetland and spawning area, plan to healthy ecosystem and surface soil transplantation as compensation plan. The alternative wetland and spawning area are not only created a various water levels like depth of water is $0{\sim}30cm,\;30{\sim}60cm$, more than 1.5m but also it leads to asian toad spawning and wildlife inhabitant. Moreover, the ecosystem and surface soil transplantation be applied to use the Quercus acutissima forest resources(114 upper trees, 71 canopy trees, 401 shrubs) and surface soil$(5,072m^3)$ in ecology creation sets.

Evaluation of dose distribution from 12C ion in radiation therapy by FLUKA code

  • Soltani-Nabipour, Jamshid;Khorshidi, Abdollah;Shojai, Faezeh;Khorami, Khazar
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2410-2414
    • /
    • 2020
  • Heavy ions have a high potential for destroying deep tumors that carry the highest dose at the peak of Bragg. The peak caused by a single-energy carbon beam is too narrow, which requires special measures for improvement. Here, carbon-12 (12C) ion with different energies has been used as a source for calculating the dose distribution in the water phantom, soft tissue and bone by the code of Monte Carlobased FLUKA code. By increasing the energy of the initial beam, the amount of absorbed dose at Bragg peak in all three targets decreased, but the trend for this reduction was less severe in bone. While the maximum absorbed dose per bone-mass unit in energy of 200 MeV/u was about 30% less than the maximum absorbed dose per unit mass of water or soft tissue, it was merely 2.4% less than soft tissue in 400 MeV/u. The simulation result showed a good agreement with experimental data at GSI Darmstadt facility of biophysics group by 0.15 cm average accuracy in Bragg peak positioning. From 200 to 400 MeV/u incident energy, the Bragg peak location increased about 18 cm in soft tissue. Correspondingly, the bone and soft tissue revealed a reduction dose ratio by 2.9 and 1.9. Induced neutrons did not contribute more than 1.8% to the total energy deposited in the water phantom. Also during 12C ion bombardment, secondary fragments showed 76% and 24% of primary 200 and 400 MeV/u, respectively, were present at the Bragg-peak position. The combined treatment of carbon ions with neutron or electron beams may be more effective in local dose delivery and also treating malignant tumors.

Technical Treatment on Foreign Invasive Marine Species of Living-things in ship′s Ballast-water (선박안정수의 해양외래침입생물체 처리 기술)

  • 소대화;장지도
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1563-1568
    • /
    • 2003
  • The introduction of invasive marine species of living things into new environments by ship's ballast water, attached to ships' hulls and via other vectors has been identified as one of the four greatest threats to the world's oceans by Global Environment Facility(GEF). Making use of the new technology of alpha-AL$_2$O$_3$ dielectric barrier layer, the strong electric-field gas discharge was introduced and obtained between micro-gap electrodes at high pressure (∼105㎩) of $O_2$ in air and $H_2O$ in seawater. The mixed air with $H_2O$ could be ionized and dissociated into large numbers of activated particles of OH, $O_2$+, O(1D), HO$_2$ and so on, and then dissolved into the ballast water to form dissolved hydroxyl radical with the concentration of ∼20mg/L. Therefore, the invasive marine species was treated effectively through the hydroxyl radical dissolved pipeline of ballast water by strong electric -field discharge.

A Scheme of Effective Water Quality Management on Lake Okjeoung (옥정호의 효율적인 수질관리방안)

  • Lee, Yo-Sang;Kim, U-Gu
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.487-497
    • /
    • 2001
  • Investigated data on Lake Okjeong were used for the simulation of water quality. According to the simulation results, the effective scheme of water quality management on reservoir has been proposed. It has been recognized that the water quality of Lake Okjeong is under eutrophic and mesotrophic condition even though there are seasonal variation. The water quality of lake is mainly affected by the inflow of pollutant load from watershed. Therefore, to estimate and quantify the accurate amounts of pollutants flowing into reservoir is absolutely necessary for the effective management of water quality on Lake Okjeong. When the pollutant load measured during 7 different rainy periods in 1999 was compared with total pollutant load in 1999. TN and TP measured during 7 different rainy periods showed almost 50% of total pollutant load. In case of SS, it was 72.8%. On the other hand, the rainfall amount measured during the 7 different rainy periods was about 17.5% of total rainfall amount in 1999. Release rate of TP shows 11.92 mg/L at fish farm site and 0.2∼1.9 mg/L at monitoring station of water quality on Lake Okjeong, and which is considered to be less than that of other foreign reservoirs under the circumstances of anoxic condition. For the effective management of water quality on Lake Okjeong. WASP5 water quality simulation model has been applied and verified, and the verified model was used to propose the effective scheme of water quality management. In this case, 6 different scenarios were applied, by changing the amount of inflow of pollutant load in each subbasin. The most effective scheme has turned out that pollutant load generated from Imsil and Gwanchon subbasin should be reduced, and the best way to improve the water a quality is to reduce the pollutant load at every subbasin. According to the simulation result, wastewater treatment facility should be located at every subbasin.

  • PDF

Assessment of Water and Pollutant Mass Balance by Soil Amendment on Infiltration Trench (침투도랑 토양치환의 물순환 및 비점오염물질저감 효과 평가)

  • Jeon, Minsu;Choi, Hyeseon;Kang, Heeman;Kim, Lee-hyung
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.145-152
    • /
    • 2020
  • Highways are characterized by high non-point pollutant emissions due to high traffic volumes and sections that cause abrupt change in driving speed (i.e. rest stations, ticketing office, etc.). Most highways in Korea were constructed with layers that do not allow adequate infiltration. Moreover, non-point pollution reduction facilities were not commonly installed on domestic highways. This study was conducted to evaluate a facility treating highway runoff and develop a cost-effective design for infiltration facilities by using soil amendment techniques. Performing soil amendment increased the hydraulic retention time (HRT) and infiltration rate in the facility by approximately 30% and 20%, respectively. The facility's efficiency of removing non-point pollutants (Total Suspend Soiled (TSS), Chemical Oxygen Demand(COD), Biological Oxygen Demand(BOD), Total Nitrogen (TN) and Total Phosphorus, (TP) were also increased by 20%. Performing soil amendment on areas with low permeability can increase the infiltration rates by improving the storage volume capacity, HRT, and infiltration area. The application of infiltration facilities on areas with low permeability should comply with the guidelines presented in the Ministry of Environment's Standards for installation of non-point pollution reduction facilities. However, soil amendment may be necessary if the soil infiltration rate is less than 13 mm/hr.

Investigation on Economical Feasibility for Energy Business of Waste Water Sludge Discharged in 'A' Industrial Complex (A-산업단지 발생 슬러지의 에너지화를 위한 경제성 검토)

  • Byun, Jung-Joo;Lee, Kang-Soo;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.61-74
    • /
    • 2012
  • Industrial complexes in Korea have been vigorously established by economic development plan and development policy of industry in 1960s. Recently, Korean government has promoted Eco Industrial Park (EIP) project to recycle by-products and wastes in industrial park In this study, we analyzed the physical and chemical properties for the sludges discharged from A industrial complex. And we investigated the economic feasibility and environmental impact of sludge to energy facilities. The analysis results indicated that the petrochemical industry were 92% in sludge production, the highest treatment amount was landfill, followed by incineration and recycling and then ocean disposal. Wastewater sludge and process sludge samples are collected and analyzed to use as basic data on economic feasibility and environmental impact. Weighted average heating value of sludge samples was 3,891kcal/kg. Based on this data, installation and operation costs, operation returns of operating the drying facility are estimated, compared with cogeneration facility. And this study examines how the payback period of each simulation(total 8 case) with the important parameter changes. As a result, it was found that what needs the shortest payback period is 3years with connection of drying facility and cogeneration facility based on the government's financial subsidy system.