• Title/Summary/Keyword: Water treatment facility

Search Result 300, Processing Time 0.031 seconds

Relationship Between Environmental Infra Operating Cost and Polluter Pay Principles (환경기초시설 운영비 보조와 오염원인자부담원칙)

  • Kang, Heechan;Kang, Sung Won;Kim, Minjoon
    • Environmental and Resource Economics Review
    • /
    • v.24 no.1
    • /
    • pp.165-187
    • /
    • 2015
  • In this paper, we tested if the sewage subsidy from Korean Water Management Fund discourage sewage fee increase by Korean local governments, and consequently hinder water quality improvement. To examine this counter-incentive effect of Water manage Fund sewage subsidy, we estimated the effect of sewage subsidy on the ratio of sewage fee revenue to environmental treatment facilities' operation cost of local governments in 2009-12, using two-stage least square estimation. We found that the sewage subsidy has negative effect on the sewage fee revenue to sewage operation cost ratio. But, the statistical significance of this effect was sensitive to model specification. And the size was too small to conclude that the counter-incentive effect was economically significant.

A Basic Experiment for a Small Sewage Treatment System Using Aquatic Plants and Microbes (소형 식물·미생물 정화조 시스템 개발을 위한 기초 실험)

  • Lee, Eun-Heui;Rhee, In-Sook;Jung, Dong-Sun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.4
    • /
    • pp.31-38
    • /
    • 2002
  • The rate of sewage treatment in South Korea was 68% in the late 1999. Sewage treatment is mostly made near big cities such as Seoul and Busan, and it is little in rural areas. Wastewater from households goes to streams directly without treatment in rural areas and pollutes streams. It is necessary to improve the progress for treatment of nutrients such as N and P which cause eutrophication in streams and lakes, because sewage treatment system in South Korea focuses on treatment of basic organic matters. Therefore it will contribute to improve discharged water quality if small sewage treatment systems by aquatic plants and microbes are introduced to rural areas where are not connected to local sewage treatment facility. This experiment was conducted to find out the best way using aquatic plants and microbes to purify wastewater from households through individual sewage treatment system. Phragmites communis, Iris pseudoacorus, Acorus calamus var. angustatus, Typha orientalis and Oenanthe javanica were used for this experiment. BOD, COD, SS, T-N and T-P were analyzed following standard methods for wastewater. The result shows that wastewater was roughly purified through pebbles and sands, and highly purified through aquatic plants and microbes especially in T-N and T-P. Iris pseudoacorus is the most effective in reduction of COD and BOD level. This system will work even in winter when plants die because microbes will be still working.

Reduction of quality of rice due to submergence during ripening stage and identification of its physiological cause

  • Lee, Hyeon-Seok;Back, Jung Seon;An, Sung Hyun;Jeong, Jae-Heok;Jeong, Han-Yong;Hwang, Woon-Ha;Yoon, Jong Tak;Lee, Gun-Hwi;Choi, Kyung-Jin
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.227-227
    • /
    • 2017
  • This study was conducted to analyze the reduction of quality and ripening rate of rice due to submergence during ripening stage and identify the physiological cause. Korean japonica type rice cultivars, Nampyeong was used in the experiment. The following 7, 14 day after heading, they were then moved into submergence treatment facility and we conducted the tests under three different submergence conditions - T1(clear water and overhead submergence), T2(Muddy water and exposure of Flag leaf end ), T3(Muddy water and overhead submergence), and the treatment lasted for 4days. The decrease of ripening rate was most severe in T3 treatment at 7days after heading, and the decrease of head rice ratio was most severe in T3 treatment at 14days after heading. Meanwhile the starch synthesis was inhibited, as the supply of assimilation products was inhibited in grain during the submergence treatment. And in stem, sucrose content was increased because the soluble carbohydrates accumulated before heading were decomposed. These changes may be due to the consumption of respiratory substrate in anaerobic conditions and the inhibition of the production of photosynthetic products by light interception. In order to see what kind of reaction occurs at the molecular level, we examined the degree of RNA expression in grain, stem and leaf. First, the expression of rna associated with starch synthesis in grain was decreased in all submergence treatment. and especially Ospul(DBE) was more decreased in 14days after heading treatment than 7days after heading treatment. This difference can explain the result that the decrease of head rice ratio was more severe at 14days after heading. And in stem, the expression of rna associated with the supply of assimilation products was decreased in submergence treatment. Finally in leaf, the expression of rna(ADH, ALDH) associated with anaerobic respiration was increased, while the expression of rna associated with photosynthesis was decreased. These results of physiological analysis can used to develop the cultivation technique and to offer the information for breeding the cultivars with tolerant characteristics to submergence stress during ripening stage in rice.

  • PDF

Characteristics of high concentration. yield multi discharge type ozonizer for dyeing water treatment (염색폐수 처리용 고농도.고수율 다중방전형 오존발생기의 특성)

  • Lee, Dong-Heon;Song, Hyun-Jig;Lee, Sang-Geun;Lee, Dong-Wook;Park, Won-Zoo;Lee, Kwang-Sik;Jean, Young-Ju;Kim, Sang-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2141-2143
    • /
    • 2000
  • In this paper, high concentration yield multi-discharge type ozonizer (MDO) of new discharge type using superposed silent discharge was designed and manufactured, MDO can be consisted with 3 kind of multi discharge type ozonizer (MDO) in accordance with power supply method that supplying power, which has 180[$^{\circ}$] phase difference, to 3 electrodes and double gap. At the moment, discharge characteristics and ozone generation characteristics of each MDO were investigated in accordance with quantity of supplied gas, the number of MDO, and the shapes of each MDO. In result, ozone generation characteristics of 17185[ppm] and 783[g/kWh] were obtained, and when ozone of 17185 [ppm] was in contact with dyeing water waste, decolorization characteristics was excellent, so it confirmed that MDO could be used as water environment improvement facility.

  • PDF

Characteristic of alumina-based microfiltration ceramic membrane

  • Hyunsoo, Kim;Oyunbileg, Purev;Eunji, Myung;Kanghee, Cho;Nagchoul, Choi
    • Membrane and Water Treatment
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2023
  • This work addresses the development of microfiltration ceramic membrane from alumina using extrusion method. The membranes were sintered at different temperatures ranging between 1000 and 1300℃. The alumina was characterized with thermogravimetric analysis, particle size distribution, X-ray diffraction, Fourier transform infrared spectrometer and scanning electron microscope analysis. Subsequently, the effect of sintering temperature on the membrane properties such as porosity, flexural strength, and pure water permeability was investigated and optimized for the sintering temperature. It is observed that with increasing sintering temperature, the porosity of the membranes decreases and the flexural strength, and pure water permeability of the membranes increase. The uncoated and coated membranes were compared at constant flux mode of filtration. Under the turbidity solution recirculation alone at 100 NTU, trans-membrane pressure (TMP) of uncoated membrane remained constant when the filtration flux was below 121 Lm-2 h -1 , while the coated membrane was 111 Lm-2 h -1 . Although suction pressure increased more rapidly at higher turbidity, coated membrane filtration showed better removal efficiency of the turbidity.

Quality Assessment of the Nationwide Water Pollution Source Survey Results on the Prioritized Toxic Water Pollutants from Industrial Sources in the Geum-River Basin by Exploratory Data Analysis (금강유역 산업계 특정수질유해물질 배출현황에 대한 탐색적 데이터 분석을 통한 전국오염원조사 결과 적합성 평가)

  • Kim, Eun-Ah;Kim, Yeon-Suk;Kim, Yong Seok;Rhew, Doug Hee;Jung, Je Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.585-595
    • /
    • 2014
  • The temporal trends of the prioritized toxic water pollutants generated and discharged from the industrial facilities in the Geum-River basin, Korea were analyzed with the results of the nationwide Water Pollution Source Survey conducted in 2001 - 2012. The statistical results indicated rapid increase in the volume of raw toxic wastewaters whereas the amount of each toxic pollutant kept fluctuating for 12 years. Serious discrepancies in the survey data of the same type of industries demonstrated a low reliability of the survey result, which stemmed from several error factors. A unit-load for each type of industrial facility was devised to estimate the amount of prioritized toxic water pollutant based on the total volume of industrial wastewater generated from the same type of industrial facilities. The supplementary measures with an effective permit issuance policy and adding survey parameters of terminal wastewater treatment plants to use them as references to the Water Pollution Source Survey were suggested as means to minimize the errors associated with the false reports from the industries.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.

A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design (감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로)

  • Han, Su Ha;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

A Study on Operating Method to Save Energy from the Adsorption Dryer in the Process of Purifying Compressed Air (고순도 압축공기 제조시스템의 흡착식 Dryer에서 에너지절감을 위한 운전방법에 관한 연구)

  • Kang, Seok-Wan;Chang, Sung-Ho;Kim, Hyeon-Joon;Kim, Sung-Soo;Lee, Yeong-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.3
    • /
    • pp.180-191
    • /
    • 2016
  • Optimizing energy usage for maximum efficiency is an essential goal for manufacturing plants in every industrial manufacturing sector. The generation and distribution of purifying compressed air is a large expense incurred in practically all manufacturing processes. Not only is the generation and treatment expensive equipment of compressed air, but frequent maintenance and effective operation is also required. As a plant's compressed air system is often an integral part of the production process, it needs to be reliable, efficient, and easy to be maintain. In this paper, we study to find operating method to save energy from the adsorption dryer in the process of purifying compressed air, which is required for a clean room production site in "A" company. The compressed air passes through a pressure vessel with two "towers" filled with a material such as activated alumina, silica gel, molecular sieve or other desiccant material. This desiccant material attracts the water from the compressed air via adsorption. As the water clings to the desiccant, the desiccant particle becomes saturated. Therefore, Adsorption dryer is an extremely significant facility which removes the moisture in the air $70^{\circ}C$ below the dew point temperature while using a lot of energy. Also, the energy consumption of the adsorption dryer can be varied by various operating conditions (time, pressure, temperature, etc). Therefore, based on existing operating experiments, we have searched operating condition to maximize energy saving by changing operating conditions of the facility. However, due to a short experiment period (from September to October), further research will be focused on considering seasonality.

Competitiveness of 'Saemi' in Sacheon Alluvial Fan as a Cultural-ecological Niche (문화생태적 적소로서 사천 선상지 '새미'의 경쟁력)

  • Dohyun Kim;Myeongcheol Jeong;Kichun Seo
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.516-532
    • /
    • 2023
  • This study is the result of analyzing the distribution of 129 Saemies discovered based on field research conducted from September 2021 to June 2023 in the Sacheon alluvial fan area through ethnoscience and niche theory. The researcher viewed the Sacheon alluvial fan area as a suitable location for irrigation where both traditional and modern hydraulic facilities are used, and the cultural and ecological study of 'Saemi', a traditional irrigation facility that attracts attention for its public value for the ecological environment according to the sustainable paradigm. By revealing its competitiveness, we aimed to contribute to finding ways to sustainably conserve and utilize Saemi. As a result of the study, Saemi is confirmed to be a competitive water facility in terms of cultural and ecological quality, considering the direction of the times and the sustainable development. If environment-friendly agricultural technology is applied to traditional water treatment facilities in the context of sustainable agriculture, it is expected that synergy will be created in productivity, public interest, and sustainability.