• 제목/요약/키워드: Water treatment facility

검색결과 301건 처리시간 0.021초

구미하수처리장 방류구에서의 소수력발전 설치 및 운영에 관한 연구 (Feasibility Study on the Construction of Small Hydro-Power Plants in Gumi Sewage Treatment Plant Discharge Point)

  • 나동훈;이승환
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.173-181
    • /
    • 2010
  • This study was conducted to investigate the possible installation of small hydro-power plant at the discharge point of Gumi sewage treatment plant (STP) using treated wastewater. Sufficient amount of water to transfer to electric power and the selection of proper location are two essential elements for the construction of small hydro-power facility. Preliminary analysis based on site visit and existing data in Gumi STP were made. Capacity of the small hydro-power plants and exact location were determined by geomorphological condition and flow duration characteristics. Flow duration characteristics and its duration curve were identified using monthly rainfall data in Gumi STP. Relevant facts of small hydro-power system in other STP were referred to adopt to Gumi STP situation. Flowrate of treated effluents and effective head between flow chamber and the location of hydraulic turbine in Gumi STP are found to be $3.70m^3$/sec and 3.5m respectively. Electric generation rate based on this feasibility study was estimated to be 86.3kW/h. Yearly electric generation rate was expected to be 932.4MMh. Proposed small hydro-power plant construction in Gumi STP is to be reasonable.

Evaluation of Rapid filtration System with Particle Size Distribution and Turbidity in Different Effective Sizes

  • Park, J.A.;Eo, S.M.;Shin, J.S.;Kim, M.H.;Yu, M.J.;Chung, S.H.
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.381-385
    • /
    • 2005
  • Characterization of particle behavior is becoming more important in performance evaluation of water treatment system as well as in operation of the system because conventional parameter, turbidity has lack of explaining ability on small sized microorganisms such like Cryptosporidium etc. Accordingly, particle counter has been introduced in evaluation and operation of the treatment system. However researches on the relationship between turbidity, particle count and/or different sand/anthracite sizes have not been concurrent. Therefore in this study, the relationship was investigated to improve performance evaluation of sand filter so as to help choosing sand/anthracite effective size as a design parameter of water treatment facility. According to the results, too small or too large effective size media filter reached to turbidity limit(0.1 NTU)earlier. However, because shallow sand layer may cause early breakthrough, the depth of sand layer should be provided enough in order to compromise water quality and productivity.

  • PDF

자연정화 기반의 현장 파일럿 실험을 통한 광산배수 구리 정화효율 평가 (Evaluation of Cu Removal from Mine Water in Passive Treatment Methods : Field Pilot Experiments)

  • 오연수;박현성;김동관;이진수;지원현
    • 자원환경지질
    • /
    • 제53권3호
    • /
    • pp.235-244
    • /
    • 2020
  • 폐광산 지역에서 발생하는 광산배수의 오염원소중 하나인 구리(Cu)는 낮은 농도에서도 독성을 지니고 있어 수계환경에 노출되기 전에 처리되어야 한다. 본 연구에서는 경남 고성군 S광산의 갱내수 정화시설의 Cu 제거효율을 개선하기 위해 석회석과 폐상퇴비를 혼합한 자연정화 기반의 반응조를 이용하여 약 9개월 동안 현장 파일럿실험을 수행하였다. 반응조별 유입수 대비 pH 증가량과 Cu 제거효율은 Successive Alkalinity Producing System (SAPS) > Reducing and Alkalinity Producing System (RAPS) > 석회석반응조 순으로 나타났다. SAPS조와 RAPS조에서는 석회석의 영향과 동시에 유기물의 분해로 인한 알칼리도의 부과로 석회석반응조보다 높은 pH 환경을 조성하였다. pH가 증가할수록 Cu 제거효율이 높아지는 결과를 통해 pH 상승이 Cu를 처리하는 주된 기작임을 확인할 수 있었다. 또한 황산염환원박테리아(Sulfate Reduction Bacteria, SRB)가 SAPS조에서 가장 많이 활성화 된 것을 확인 할 수 있어, 황산염환원반응도 Cu를 제거시키는 기작에 관여함을 판단할 수 있었다. 본 연구는 S광산에서 발생하는 광산배수의 특성에 알맞은 맞춤형 정화공정을 도출하기 위해 현장 그대로의 조건에서 실험을 수행한 것에 의의가 있으며, 향후 정화시설의 개선에 있어 공법 선정에 도움을 줄 수 있을 것이다.

대체비용법을 이용한 하천 수질개선편익 산정 (Estimation of Water Quality Improvement Benefit Using Replacement Cost Approach)

  • 여규동;이충성;김길호;심명필
    • 한국수자원학회논문집
    • /
    • 제42권4호
    • /
    • pp.343-353
    • /
    • 2009
  • 본 연구의 목적은 댐방류에 의한 하류하천의 수질개선효과를 대체댐이 아닌 하수처리시설을 대체시설의 비용으로 적용하여 국내 실정에 맞게 편익으로 산정하는 방법론을 제시하는 것이다. 이를 위해 댐을 대체하는 시설은 댐의 방류수와 동일한 기능을 제공해야 하고, 두 시설간의 비용을 객관적으로 비교할 수 있어야 한다. 본 논문은 대체비용법을 이용하여 수질개선편익을 산정하기 위해 대체시설(하수처리장)의 비용 산정방법, 비용 편익분석 관련 기준인 내용연수와 대수선비율의 근거를 제시하였다. 사례연구로서, 낙동강수계의 내성천에 계획한 송리원댐의 수질개선편익을 산정하였으며, 그 결과는 연평균 방류시 644,006 백만원, 수질악화기의 최대방류시 1,351,526 백만원으로 산정되었다. 본 연구방법은 환경개선용수 공급사업시 실무에서 활용 가능한 수질개선 편익산정방법이 될 것으로 기대된다.

Nutrient removal from secondary effluent using filamentous algae in raceway ponds

  • Min, Kyung-Jin;Lee, Jongkeun;Cha, Ho-Young;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.191-199
    • /
    • 2019
  • In this study, we investigated the cultivation possibility using Hydrodictyon reticulatum in a continuous raceway pond as a tertiary sewage treatment plant. The cultivation possibility was evaluated by varying the light quantity, wavelength, and hydraulic retention time (HRT). Experimental results showed that the growth rates of algae and the removal efficiencies of nutrients increased as the light quantity increased, and the maximum photosynthetic rate was maintained at $100{\mu}mol/m^2{\cdot}s$ or higher. When wavelength was varied, nutrient removal efficiency and growth rate increased in the following order: green light, red light, white light, and blue light. The nutrient removal efficiencies and algae productivity in HRT 4 d were better than in HRT 8 d. We conclude that if Hydrodictyon reticulatum is cultivated in a raceway pond and used as a tertiary treatment facility in a sewage treatment plant, nutrients can be effectively removed, and production costs can be reduced.

육상시추용 Mud treatment system의 유동특성 평가 (Evaluation of Flow Characteristics of Mud Treatment System for Onshore Drilling)

  • 김승찬;전중호
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.763-772
    • /
    • 2021
  • Drilling Mud Treatment Systems are widely used for Oil Gas drilling mud circulation, horizontal directional drilling mud recycling, geothermal drilling, mining, coal exploration drilling, water well drilling. Degasser is a device used in drilling to remove gasses from drilling fluid which could otherwise form bubbles. For small amounts of entrained gas in a drilling fluid, the degasser can play a major role of removing small bubbles that a liquid film has enveloped and entrapped. As with the desander, its purpose is to remove unwanted solids from the mud system. The smaller cones allow the desilter to efficiently remove smaller diameter drill solids. In this study, a simulation study is conducted on the degasser of the facility in the Mud Treatment System to conduct a performance review on the gas separation in the mud.

오존처리공정의 배오존 재활용 마이크로버블시스템 개발 (Development of a Micro-Bubble System for Ozone Off-Gas Recycling in the Ozone Treatment Process)

  • 조영만;정재억;이광헌;정용준
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1061-1068
    • /
    • 2022
  • The purpose of this study was to develop a recycling system for ozone off-gas. Although the ozone transmission rate of the injector method differs slightly depending on the ozone injection rate, it reaches approximately 99%, which is very high. During the increase in water inflow to the ozone recycling system from 2 L/min to 10 L/min, the average ozone recycling rate was 99.4% at a 1 ppm ozone injection rate, 98.6% at a 2 ppm ozone injection rate, 98.1% at a 3 ppm ozone injection rate. Ozone treatment facility operating costs can be divided into the costs of pure oxygen production, ozone production, and maintenance. The annual operating costs of ozone treatment facilities in Korea are estimated to be approximately 38.9 billion won. The annual savings are estimated to be approximately 5.8 billion won when the ozone transfer rate of the diffuser method, which is mostly employed in domestic water treatment plants, is 85% and 15% of the ozone is recycled.

하수도정비기본계획 시행 후의 투자적정성 분석에 관한 사례 연구 (Case Study of Investment Adequacy Analysis After Implementing Master Plan on Sewerage Rehabilitation)

  • 박규홍;강병준;임병인;강만옥;박주양;김성태;박완규
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.503-510
    • /
    • 2015
  • The objective of this study is to analyze the investment adequacy of the projects implemented according to the master plan on sewerage rehabilitation at Seoul. The planned and actually implemented ratio of invested money on sewage treatment plants (STPs) to sewers were compared in two temporal periods. Though the planned ratio of investment on STPs to sewers was 50:50 (in 2009-2020), the actual implemented ratio in 2009-2013 was 34:66. Until 2020, the greater investment ratio on STPs to sewers should be made considering the necessity of coping with stricter legal compliance on advanced treatment, stormwater treatment and so on. The priority of the planned and partially implemented projects among four STPs and at each STP was evaluated. Considering only the performance indicator of reduced load of BOD, T-N, T-P per the capacity of each STP facility, the performance among four STPs was shown as Jung-Rang>Tan-Cheon>Seo-Nam>Nan-Ji. The reverse order of the performance results in the past may be considered for future investment priority, but the efficiency of operation implemented at each STP, deteriorated status of each STP, investment in the past and so forth should also be considered. As for the priority of projects conducted within each STP, projects related to legal compliance (such as advanced tertiary treatment, stormwater treatment, etc.) have highest priority. Odor-related project and inhabitant-friendly facility related projects (such as building park on STPs, etc.) has lower priority than water quality related projects but interactivity with end-users of sewerage should also be important.

식품폐수처리시설의 설비효율 개선에 따른 온실가스 배출량 평가 (Estimation of GHGs Emission to Improvement of Facility Efficiency in the Food wastewater Treatment Process)

  • 안상형;송장헌;김산;정진도
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.378-384
    • /
    • 2019
  • 식품 폐수 처리 설비중 폐수처리장 폭기조 송풍 설비 개선을 통한 수질개선 효과 및 전기사용량 변화에 따른 온실가스 발생량을 평가 하였으며, 식품 폐수처리장에서 발생되는 슬러지를 탈수, 보관, 이송하는 설비의 효율적인 개선을 통한 전기사용량 개선전과 개선후 변화에 따른 온실가스 발생량도 함께 평가하였다. 폐수처리장 설비 개선에 따른 온실가스 배출량 평가는 폐수처리 공정으로 부터의 직접배출과 전력사용으로부터의 간접배출량으로 구분 된다. 폐수처리장 수질 개선 효과는 BOD 제거율이 63.3%, COD 제거율 42.0%, SS 제거율 71.0%, T-N제거율이 39.6%로 나타났으며, 폐수처리에 의한 온실가스 직접배출량(Scope 1)과 전력소비량 변화에 대한 온실가스 간접배출량(Scope 2)을 적용하여 온실가스 배출량을 산정한 결과 설비 개선전 3,668.8tCO2eq./yr 에서 설비 개선후 3,392.8tCO2eq./yr 으로 감소 하여 총 276.0tCO2eq./yr (8.0%)의 온실가스 감축 효과가 있는 것으로 평가 되었다. 이상의 결과는 배출원의 수질 개선 효과로 인한 것이 아니라 전기사용량 감소로 인해 온실가스 배출량이 감소하였기 때문이다.

낙동강 유역에 위치한 폐수처리시설 최종방류수의 수질과 항생물질 분석 (Analysis of Water Quality Components and Antibiotics in the Final Effluent of Wastewater Treatment Facilities in the Nakdong River Basin)

  • 박경덕;강동환;조원기;유훈선;윤연수;김병우
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.857-870
    • /
    • 2020
  • In this study, the antibiotic components in the final effluent from the 12 wastewater treatment facilities located in the Nakdong River basin were investigated, and the correlation between organic matters, nutrients and antibiotics was analyzed. In the final effluent of the wastewater treatment facilities, three sulfonamides antibiotics (sulfamethazine, sulfathiazole, sulfachlorpyridazine) and tetracyclines antibiotics (oxytetracycline, doxycycline) were detected. Sulfamethazine were detected at all points and ranged from 10.398 to 278.784 ng/L. Sulfathiazole were detected at 6 points (Andong, Gumi, Hapcheon, Miryang, Uiryeong, Haman), and ranged from 23.773 to 144.468 ng/L. The correlation coefficients between sulfathiazole and TSS, COD, TOC, NH3-N, NO2-N, and T-N components were high in the range of 0.73 to 0.92. The correlation coefficient between sulfamethazine and T-N was 0.48, and the correlation with the rest of the water quality components was low. The correlation coefficient between sulfamethazine and sulfathiazole was 0.78. Through this study, it was confirmed that the concentration of sulfonamides antibiotics was higher than the concentration of tetracyclines antibiotics in the final effluent of 12 wastewater treatment facilities in the Nakdong River basin, and the concentration of sulfathiazole increased with organic matters and nutrients.