• 제목/요약/키워드: Water treatment

검색결과 12,085건 처리시간 0.04초

낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석 (Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin)

  • 조현경;김상민
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

국내정수장의 잔류염소농도에 대한 조사연구 (Statistical Analysis of Chlorine Residual in Korean Drinking Water)

  • 손진식;강효순
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.281-287
    • /
    • 2006
  • Maintaining adequate chlorine residual is crucial in water treatment facilities, Treatment technique, newly promulgated regulation, requires sufficient disinfection in order to control more resistant microorganisms such as Viruses and Giardia lamblia. Each water treatment plant should report various water qualities including chlorine residual and disinfection by-products, thus plenty of data has been generated. Even though statistical analysis using these data are forced to investigate the status and effect of water qualities in water facilities very few researches have been performed in korea. This study performed statistical analysis of chlorine residual during three years in Korean drinking water. The average chlorine residual concentrations were 0.701mg/L, 0.738mg/L, 0.763mg/L in 2002, 2003, 2004, respectively. Monthly variations of chlorine residual was not significant. ANOVA result showed that yearly variance of chlorine residual is different in only less than $5000m^3/day$ of water treatment capacity. The statistical analysis can help government to establish new regulation with scientific basis.

Advanced Water Treatment by Tubular Alumina Ceramic Ultrafiltration: Effect of Periodic Water-back-flushing Period

  • Park, Jin-Yong;Lee, Song-Hui
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • The periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic ultrafiltration (UF) system for Gongji stream water treatment in Chuncheon city. The filtration time (FT), which was the water-back-flushing period, 2 min with periodic 15 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 6.35 L. Consequently FT 2 min at back-flushing time (BT) 15 sec could be the optimal condition in advanced UF water treatment of Gongji stream. Then the average rejection rates of pollutants by our tubular ceramic UF system were 99.4% for Turbidity, 31.8% for $COD_{Mn}$, 22.6% for $NH_3$-N and 65.9% for T-P.

CFD를 이용한 농축조 슬러지의 유출흐름특성 해석 (Analysis of the sludge thickening characteristics in the thickener using CFD Model)

  • 박노석;문용택;김병군;김홍석
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.

SWMM 모형을 이용한 비점오염 분석 및 CSO 관리방안 연구 - 부산시 온천천 유역 대상 - (The NPS Analysis and CSO Management Based on SWMM for Oncheon Basin)

  • 신현석;손정화;장종경;손태석;강두기;조덕준
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.268-280
    • /
    • 2009
  • Oncheon basin which are located in Busan is divided into 43 basin on the basis of main pipe, constructed with Storm Water Management Model (SWMM). Occurrence situation for Outflow and pollutant loads by long-term continuous rainfall is examined for treatment district and river analysis point of Oncheon basin and a reduction vs effectiveness table for effective CSOs managements is made for each of treatment districts according to each of managements. In case that treatment equipment is located at the discharge point of CSO, treatment efficiency is analysed. It is supposed that treatment equipment have an efficiency on the basis of a concentration and runoff discharge over a critical flow is discharged with it untreated and treating runoff discharge with treatment equipment at each of runoff discharge points and treating it gathered at sewage treatment plant (STP) through trunk sewer is compared for a relative treatment efficiency.

Present State of Membrane Filtration for Water Treatment in Japan

  • Kiso, Yoshiaki
    • 멤브레인
    • /
    • 제13권1호
    • /
    • pp.1-8
    • /
    • 2003
  • Membrane filtration systems have been focusing and increasing rapidly in the filed of drinking water treatment because of several reasons. We describe briefly the present state of membrane filtration processes for drinking water treatment in Japan: including background, objectives, membrane suppliers, and some cases of actual plants.

정수슬러지 유래 흡착제와 첨착활성탄의 암모니아 및 포름알데히드 기체 흡착 성능 비교 (Comparison of Adsorption Performance of Ammonia and Formaldehyde Gas Using Adsorbents Prepared from Water Treatment Sludge and Impregnated Activated Carbon)

  • 이철호;박나영;김고운;전종기
    • 공업화학
    • /
    • 제27권1호
    • /
    • pp.62-67
    • /
    • 2016
  • 본 연구에서는 정수슬러지를 원료로 사용하여 펠렛형 흡착제를 제조하고 질소흡착법, XRD, XRF 및 암모니아 승온탈착법 등을 사용하여 물리 화학적 특성을 분석하였다. 정수슬러지 유래 펠렛형 흡착제와 첨착활성탄의 암모니아 및 포름알데히드 기체의 흡착 성능을 비교하였다. 정수슬러지로부터 제조된 펠렛형 흡착제는 첨착활성탄보다 표면적과 기공부피는 훨씬 작지만 암모니아를 훨씬 더 많이 흡착할 수 있었다. 이는 정수슬러지로부터 제조된 펠렛형 흡착제 표면에 산점이 훨씬 더 많이 분포해 있어서 화학흡착에 의해 암모니아를 흡착하기 때문이다. 반면에, 산성가스인 포름알데히드 가스 흡착의 경우는 넓은 표면적과 발달된 기공으로 인하여 첨착활성탄의 흡착성능이 정수슬러지로부터 제조된 펠렛형 흡착제에 비해 훨씬 우수하였다.

반도체 산업폐수의 재이용 기술에 관한 연구 (A Study on the Waste Water Recycling Technology for Semiconductor Industry)

  • 지은상;김재우;신대윤
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.137-142
    • /
    • 1999
  • Current semiconductor industry factories are relying on the end-of-pipe treatment technology for waste water treatment and thus they mostly suffer from severe industrial water shortage. As a result in order to solve those waste and industrial water problems, there requires to be changed to the Clean Technology, that is Pollution Prevention Technology. Through above strategic actions with the Clean Technology, we shall strength more powerful and logical environmental pollution prevention system than those in the past. By changing the end-of-pipe treatment technology for waste water treatment and thus they mostly suffer from severe industrial water problems, there requires to be changed to the Clean Technology, that is Pollution Prevention Technology. Through above strategic actions with the Clean Technology, we shall strength more powerful and logical environmental pollution prevention system than those in the past. By changing the end-of-pipe treatment technology with physical, chemical and biological treatment methods as a mixed stream basis for treating of semiconductor waste stream into clean technology with pollution prevention technology as a waste segregation basis, we can bet 20 to 30% investment reduction as compared with end-of-pipe treatment technology.The results for water quality analysis were as follows : 1. Water quality analysis of the before treatment : pH : 9~10.5, Conductivity : $300~7,000{\mu}s/cm$, TDS : more then $3,000mg/{\ell}$, COD : $200~250mg/{\ell}$, SS : $500~600mg/{\ell}$, n-H : $8.3mg/{\ell}$ 2. Water quality analysis of the after treatment : pH : 6.5~7.5, Conductivity : 0.059, TDS : $40{\mu}s/cm$, COD : $20mg/{\ell}$, SS : $5mg/{\ell}$ n-H : $0.6mg/{\ell}$

  • PDF

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • 제12권1호
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.

유전알고리즘을 이용한 하천수질관리모형에 관한 연구 (A Study on the River Water Quality Management Model using Genetic Algorithm)

  • 조재현;성기석
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.453-460
    • /
    • 2004
  • The objective of this research is to develop the water quality management model to achieve the water quality goal and the minimization of the waste load abatement cost. Most of existing water quality management model can calculate BOD and DO. In addition to those variables, N and P are included in the management model of this study. With a genetic algorithm, calculation results from the mathematical water quality model can be used directly in this management model. Developed management model using genetic algorithm was applicated for the Youngsan River basin. To verify the management model, water quality and pollution source of the Youngsan River had been investigated. Treatment types and optimum treatment costs of the existing and planned WWTPs in the baisn were calculated from the model. The results of genetic algorithm indicate that Kwangju and Naju WWTP have to do the advanced treatment to achieve the water quality goal about BOD, DO and TP. Total annual treatment cost including the upgrade cost of existing WWTPs in the Youngsan River basin was about 50.3 billion Won.