• Title/Summary/Keyword: Water time

Search Result 15,198, Processing Time 0.046 seconds

Scientific Study for the Standardization of the Preparation Methods for Paeksolgi(I) (백설기 조리법의 표준화를 위한 조리과학적 연구(I))

  • 김기숙
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.2
    • /
    • pp.79-87
    • /
    • 1987
  • Paeksolgi is a typical Korean rice cake made by steaming rice powder added sugar, water and salt. This study attempted to clarify the factors which affect the textural characteristics, and to examine the effects of various steaming time and volume of adding water on sensory characteristics and Instron measurement on textures of Paeksolgi. Evaluation was conducted through sensory evaluation and objective evaluation. The results were summarized as follows. 1. In the preparation, the significant factors were soaking time, volume of sugar, and the interaction between soaking time and volume of adding water. And, Kind of sweetener, volume of adding water, steaming time, condition of powder, and the interaction between soaking time and steaming time, and between soaking time and volume of adding water, and between kind of sweetener and condition of powder, and between steaming time and volume of sugar were the significant factors which affected the textural characteristics of Paeksolgi. 2. In sensory evaluation on the various steaming time and volume of adding water, Paeksolgi made by steaming rice powder added water of 10% for 30 min. showed the most favorite tendency on the overall quality. The results of Instron measurement indicated that hardness, gumminess and chewiness tended to decrease as volume of adding water increased in same steaming time.

  • PDF

A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter (대구경 관로의 배수시간 산정을 위한 수치해석 기법)

  • Shin, Byoung-Ho;Choi, Doo-Yong;Jeong, Kwansue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

The Variation of the Urban Water Use and the Distribution Reservior Capacity with Time for a Day (상수도(上水道)의 1일(日) 급수량(給水量) 및 배수지(配水池) 용량(容量) 변화(變化)에 관한 연구(硏究))

  • RHEE, Kyoung Hoon;PARK, Sung Chun;MOON, Byoung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.118-126
    • /
    • 1995
  • The variation of the urban water demand and the amount of water in the distribution reservoir was studied with time for a day. The city of Kwangju in Korea was selected as a study area. The population of Kwangju in the end of 1993 was more than one million and two hundred thousand peoples. The average of daily water use in 1993 was about three hundred and fifty thousand tons a day. One day was devided into 12 divisions with a 2 hour increment. The water use demand related to the amount of water in the distribution reservoir was observed for the given time interval of a day. The water use index was defind in percentage that indicates the ratio of the amount of water use for a time interval to the amount of water use for a day. The water use index with consideration of the water stored in the reservoir was found to be useful to manage and to operate the water supply systems in real time.

  • PDF

부산시 동래 온천지역의 양수량, 온천수위, 강수량의 관련성 연구

  • 차용훈;함세영;정재열;장성;손건태
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.455-458
    • /
    • 2004
  • This study uses time series analyses to evaluate fluctuation of water levels in a geothermal water well due to pumping, in relation to rainfall at Dongrae hot-spring site on the southeastern coast of tile Korean peninsula. The volume of water pumped from the public study wells ranges from 542 to 993 m$^3$/month, and the minimum water level ranged from 35 to 144.7 m during the measured period. Autocorrelation analysis was conducted for the withdrawal rate at the public wells, water levels and rainfall. The autocorrelation of the withdrawal rate shows distinct periodicity with 3 months of lag time, the autocorrelation of rainfall shows weak linearity and short memory with 1 months of lag time, and the autocorrelation of water levels shows weak linearity and short memory with 2 months of lag time. The cross-correlation between the pumping volume and the minimum water level shows a maximum value 1 at a delayed time of 34 months. The cross-correlation between rainfall and the minimum water level shows a maximum value of 0.39 at a delayed time of 32 months.

  • PDF

Study on the Water and Material Exchange in Deukryang Bay 1. Volume Transport and Turnover Time of Sea Water (득량만의 해수 교환 및 물질 순환에 관한 연구 1 . 해수의 수송량 및 교환 시간)

  • 조규대;이충일
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.311-320
    • /
    • 1998
  • The volume transport and turnover time of the Deukryang Bay. located at the southern area of Korea, were calculated based on the current meter(RCM-7,ACM 16M) data observed at the three gateways of the tegrating observed data and then averaging on time. dangdo and Kogumdo. The total water volume transports through three entrances of the bay in May and October were $3.9{\times}10-2Sv, 3.4{\times}10^{-2}Sv(1Sv=10^6m^3s^{-1}$) and turnover time were 0.97day, 1.12day, respectively. Semidiurnal tides were predominant (70~85%). The water volume transports by residual currents were 2~4% of total water volume transports . The average fraction of fresh water calculated by tidal prism method using salinity difference between inflow current and outflow current through three entrances In Deukryang Bay was about 0.06% of total volume and the flushing time of fresh water was estimated as 0.97day.

  • PDF

The effect of water turnover time on decomposition of wild rice (Zizania latifolia) and nutrient dynamics in an artificial wetland system

  • Lee, Bo Eun;Kim, Jae Geun
    • Journal of Ecology and Environment
    • /
    • v.37 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • The effect of different turnover time of water on the decomposition of emergent macrophyte litter (Zizania latifolia Griseb.) was investigated using a microcosm experiment. Microcosm treatment represented different turnover time of water; 1, 2, 4 and 8 weeks. The litterbags from each treatment were retrieved every 2 weeks until the 8th week and the water simultaneously sampled with the litterbag. The dry weight and the content of major cations in the litter, and the content of available N, P, and major cations in the water were analyzed. Dry weight loss after 8 weeks indicated the lower decay rates under the condition of short turnover time of water. Major cations from the litter and the water showed that the leached amounts of K and Mg from the litter were highest in the 2nd week and dramatically decreased from the 4th week. The dynamics of available nitrogen and phosphorus in the water showed that as the water turnover time was getting longer, the amounts of available nitrogen and phosphorus remained higher. These results suggest that wetlands with longer turnover time of water could maintain the increased nitrogen and phosphorus and no outflow of the nutrients could cause eutrophication problem.

Delay Time Estimation of Recharge in the Hancheon Watershed, Jeju Island (제주도 한천유역의 함양 지체시간 산정)

  • Kim, Nam-Won;Na, Hanna;Chung, Il-Moon
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.605-613
    • /
    • 2014
  • In this work, the delay time for groundwater recharge was estimated by comparing simulated recharges by means of SWAT(Soil and Water Assessment Tool) model and WTF(Water Table Fluctuation) method. The delay time for groundwater recharge means that the time when the water from rainfall travelled through vadose zone just after getting out of soil zone bottom. As measuring this delay time is almost impossible, we used to compare the estimated values from modeling(SWAT) and analytic method(WTF). The test site is Hancheon watershed which has 8 groundwater measurement stations. The results show that the altitude has a linear relationship with the estimated delay time values. To validate these results, we conducted corelation analysis between transformed groundwater levels and observed ones. The results showed that computed groundwater levels have good corelation($R^2$=0.97, 0.87, respectively). The estimated delay time would be used for the groundwater behaviour characteristics in vadose zone. As recharge rates vary according to the height, the delay time is thought to be an import variable for the proper groundwater recharge estimation.

Effects of water saturation time on energy dissipation and burst propensity of coal specimens

  • Yang, Xiaohan;Ren, Ting;Tan, Lihai;Remennikov, Alex
    • Geomechanics and Engineering
    • /
    • v.24 no.3
    • /
    • pp.205-213
    • /
    • 2021
  • Water infusion has long been taken as an effective way to eliminate coal burst risk as coal properties can be loosen and soften by water infusion. However, not all industrial trials of water infusion for coal burst prevention have been necessarily effective in all situations as the effectiveness of this method can be affected by water infusion time, coal properties and the parameters of water injection. Hence, some fundamental issues including the effects of water infusion time on burst propensity and energy evolution need to be further discussed. In this paper, four groups of coal specimens with 0 day, 5 days, 10 days, and 15 days water saturation time are tested under uniaxial compression load with the application of AE monitoring. To comprehensively compare the burst behavior of coal specimens under different water saturation time, stress-strain curves, AE counts, fragmentation characteristics and burst propensity of these groups are analyzed. It was found by this research that sufficient water saturation can mitigate the burst behavior of coal samples while insufficient water infusion might cannot reach the burst mitigation aims.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

Changes in Absorbency and Drying Speed of a Quick-drying Knit Fabric by Repeated Laundering

  • Roh, Eui-Kyung;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.12
    • /
    • pp.2062-2072
    • /
    • 2010
  • This research evaluates the change of the water absorbency and drying speed of a quick-drying knit fabric by repeated laundering and laundering conditions and investigates the influence of laundering conditions on the functional properties of the knit fabric. Four factors of laundering conditions were studied: detergent, water hardness, water temperature, and frequency of rotation. Knit fabrics were washed for 25 laundering cycles in a drum-type washing machine with nine different laundering conditions derived from an orthogonal array. The properties of knit fabrics were measured with a drop absorption test, a strip test, and a drying time test. Relaxation shrinkage pointed to a change in the structural characteristics of the knit fabric. Wetting time was faster and wickability was greater in the knit fabrics that underwent 5 laundering cycles; in addition, there were no obvious changes in wetting time and wickability. The detergent was the most important factor in wetting time (40.4%) and wickability (60% or above). Water hardness, water temperature and RPM had less of an effect on wetting time and wickability. There were no significant differences between the levels of laundering conditions (except for detergent) on wetting time and wickability. Drying times with neutral and alkali were slower by repeated laundering; however, there was no obvious change in drying time. Hardness, water temperature and RPM had less of an impact on drying time.